Accuracy of Bilistick (a Point-of-Care Device) to Detect Neonatal Hyperbilirubinemia. (20th May 2020)
- Record Type:
- Journal Article
- Title:
- Accuracy of Bilistick (a Point-of-Care Device) to Detect Neonatal Hyperbilirubinemia. (20th May 2020)
- Main Title:
- Accuracy of Bilistick (a Point-of-Care Device) to Detect Neonatal Hyperbilirubinemia
- Authors:
- Kamineni, Bhargavi
Tanniru, Anusha
Vardhelli, Venkateshwarlu
Sharma, Deepak
Pawale, Dinesh
Kulkarni, Dattatray
Muppidi, Pranitha Reddy
Deshabhotla, Saikiran
Murki, Srinivas - Abstract:
- Abstract: Introduction: Early diagnosis and appropriate management of neonatal jaundice is crucial in avoiding severe hyperbilirubinemia and brain injury. A low-cost, minimally invasive, point-of-care (PoC) tool for total bilirubin (TB) estimation which can be useful across all ranges of bilirubin values and all settings is the need of the hour. Objective: To assess the accuracy of Bilistick system, a PoC device, for measurement of TB in comparison with estimation by spectrophotometry. Design/methods: In this cross-sectional clinical study, in infants who required TB estimation, blood samples in 25-µl sample transfer pipettes were collected at the same time from venous blood obtained for laboratory bilirubin estimation. The accuracy of Bilistick in estimating TB within ±2 mg/dl of bilirubin estimation by spectrophotometry was the primary outcome. Results: Among the enrolled infants, 198 infants were eligible for study analysis with the mean gestation of 36 ± 2.3 weeks and the mean birth weight of 2368 ± 623 g. The median age at enrollment was 68.5 h (interquartile range: 48–92). Bilistick was accurate only in 54.5% infants in measuring TB within ±2 mg/dl difference of TB measured by spectrophotometry. There was a moderate degree of correlation between the two methods ( r = 0.457; 95% CI: 0.339–0.561, p value < 0.001). Bland–Altman analysis showed a mean difference of 0.5 mg/dl (SD ± 4.4) with limits of agreement between −8.2 and +9.1 mg/dl. Conclusion: Bilistick as a PoCAbstract: Introduction: Early diagnosis and appropriate management of neonatal jaundice is crucial in avoiding severe hyperbilirubinemia and brain injury. A low-cost, minimally invasive, point-of-care (PoC) tool for total bilirubin (TB) estimation which can be useful across all ranges of bilirubin values and all settings is the need of the hour. Objective: To assess the accuracy of Bilistick system, a PoC device, for measurement of TB in comparison with estimation by spectrophotometry. Design/methods: In this cross-sectional clinical study, in infants who required TB estimation, blood samples in 25-µl sample transfer pipettes were collected at the same time from venous blood obtained for laboratory bilirubin estimation. The accuracy of Bilistick in estimating TB within ±2 mg/dl of bilirubin estimation by spectrophotometry was the primary outcome. Results: Among the enrolled infants, 198 infants were eligible for study analysis with the mean gestation of 36 ± 2.3 weeks and the mean birth weight of 2368 ± 623 g. The median age at enrollment was 68.5 h (interquartile range: 48–92). Bilistick was accurate only in 54.5% infants in measuring TB within ±2 mg/dl difference of TB measured by spectrophotometry. There was a moderate degree of correlation between the two methods ( r = 0.457; 95% CI: 0.339–0.561, p value < 0.001). Bland–Altman analysis showed a mean difference of 0.5 mg/dl (SD ± 4.4) with limits of agreement between −8.2 and +9.1 mg/dl. Conclusion: Bilistick as a PoC device is not accurate to estimate TB within the clinically acceptable difference (±2 mg/dl) of TB estimation by spectrophotometry and needs further improvement to make it more accurate. … (more)
- Is Part Of:
- Journal of tropical pediatrics. Volume 66:Number 6(2020:Dec.)
- Journal:
- Journal of tropical pediatrics
- Issue:
- Volume 66:Number 6(2020:Dec.)
- Issue Display:
- Volume 66, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 66
- Issue:
- 6
- Issue Sort Value:
- 2020-0066-0006-0000
- Page Start:
- 630
- Page End:
- 636
- Publication Date:
- 2020-05-20
- Subjects:
- neonatal jaundice -- bilirubin -- Bilistick -- hyperbilirubinemia -- point-of-care device
Pediatrics -- Periodicals
Tropical medicine -- Periodicals
Pediatrics -- Periodicals
Tropical Medicine -- Periodicals
Environmental Health -- Periodicals
Infant
Child
618.929883 - Journal URLs:
- http://tropej.oupjournals.org/ ↗
http://www3.oup.co.uk/tropej/ ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0142-6338;screen=info;ECOIP ↗ - DOI:
- 10.1093/tropej/fmaa026 ↗
- Languages:
- English
- ISSNs:
- 0142-6338
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.090000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15053.xml