Dose–response of EBT3 radiochromic films to proton and carbon ion clinical beams. (20th December 2016)
- Record Type:
- Journal Article
- Title:
- Dose–response of EBT3 radiochromic films to proton and carbon ion clinical beams. (20th December 2016)
- Main Title:
- Dose–response of EBT3 radiochromic films to proton and carbon ion clinical beams
- Authors:
- Castriconi, Roberta
Ciocca, Mario
Mirandola, Alfredo
Sini, Carla
Broggi, Sara
Schwarz, Marco
Fracchiolla, Francesco
Martišíková, Mária
Aricò, Giulia
Mettivier, Giovanni
Russo, Paolo - Abstract:
- Abstract: We investigated the dose–response of the external beam therapy 3 (EBT3) films for proton and carbon ion clinical beams, in comparison with conventional radiotherapy beams; we also measured the film response along the energy deposition-curve in water. We performed measurements at three hadrontherapy centres by delivering monoenergetic pencil beams (protons: 63–230 MeV; carbon ions: 115–400 MeV/u), at 0.4–20 Gy dose to water, in the plateau of the depth-dose curve. We also irradiated the films to clinical MV-photon and electron beams. We placed the EBT3 films in water along the whole depth-dose curve for 148.8 MeV protons and 398.9 MeV/u carbon ions, in comparison with measurements provided by a plane-parallel ionization chamber. For protons, the response of EBT3 in the plateau of the depth-dose curve is not different from that of photons, within experimental uncertainties. For carbon ions, we observed an energy dependent under-response of EBT3 film, from 16% to 29% with respect to photon beams. Moreover, we observed an under-response in the Bragg peak region of about 10% for 148.8 MeV protons and of about 42% for 398.9 MeV/u carbon ions. For proton and carbon ion clinical beams, an under-response occurs at the Bragg peak. For carbon ions, we also observed an under-response of the EBT3 in the plateau of the depth-dose curve. This effect is the highest at the lowest initial energy of the clinical beams, a phenomenon related to the corresponding higher LET in the filmAbstract: We investigated the dose–response of the external beam therapy 3 (EBT3) films for proton and carbon ion clinical beams, in comparison with conventional radiotherapy beams; we also measured the film response along the energy deposition-curve in water. We performed measurements at three hadrontherapy centres by delivering monoenergetic pencil beams (protons: 63–230 MeV; carbon ions: 115–400 MeV/u), at 0.4–20 Gy dose to water, in the plateau of the depth-dose curve. We also irradiated the films to clinical MV-photon and electron beams. We placed the EBT3 films in water along the whole depth-dose curve for 148.8 MeV protons and 398.9 MeV/u carbon ions, in comparison with measurements provided by a plane-parallel ionization chamber. For protons, the response of EBT3 in the plateau of the depth-dose curve is not different from that of photons, within experimental uncertainties. For carbon ions, we observed an energy dependent under-response of EBT3 film, from 16% to 29% with respect to photon beams. Moreover, we observed an under-response in the Bragg peak region of about 10% for 148.8 MeV protons and of about 42% for 398.9 MeV/u carbon ions. For proton and carbon ion clinical beams, an under-response occurs at the Bragg peak. For carbon ions, we also observed an under-response of the EBT3 in the plateau of the depth-dose curve. This effect is the highest at the lowest initial energy of the clinical beams, a phenomenon related to the corresponding higher LET in the film sensitive layer. This behavior should be properly modeled when using EBT3 films for accurate 3D dosimetry. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 62:Number 2(2017:Jan.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 62:Number 2(2017:Jan.)
- Issue Display:
- Volume 62, Issue 2 (2017)
- Year:
- 2017
- Volume:
- 62
- Issue:
- 2
- Issue Sort Value:
- 2017-0062-0002-0000
- Page Start:
- 377
- Page End:
- 393
- Publication Date:
- 2016-12-20
- Subjects:
- protons -- carbon ions -- hadrontherapy -- radiochromic film dosimetry -- EBT3
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/aa5078 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15046.xml