Quantification of tumor perfusion using dynamic contrast-enhanced ultrasound: impact of mathematical modeling. (16th January 2017)
- Record Type:
- Journal Article
- Title:
- Quantification of tumor perfusion using dynamic contrast-enhanced ultrasound: impact of mathematical modeling. (16th January 2017)
- Main Title:
- Quantification of tumor perfusion using dynamic contrast-enhanced ultrasound: impact of mathematical modeling
- Authors:
- Doury, Maxime
Dizeux, Alexandre
de Cesare, Alain
Lucidarme, Olivier
Pellot-Barakat, Claire
Bridal, S Lori
Frouin, Frédérique - Abstract:
- Abstract: Dynamic contrast-enhanced ultrasound has been proposed to monitor tumor therapy, as a complement to volume measurements. To assess the variability of perfusion parameters in ideal conditions, four consecutive test–retest studies were acquired in a mouse tumor model, using controlled injections. The impact of mathematical modeling on parameter variability was then investigated. Coefficients of variation (CV) of tissue blood volume (BV) and tissue blood flow (BF) based-parameters were estimated inside 32 sub-regions of the tumors, comparing the log-normal (LN) model with a one-compartment model fed by an arterial input function (AIF) and improved by the introduction of a time delay parameter. Relative perfusion parameters were also estimated by normalization of the LN parameters and normalization of the one-compartment parameters estimated with the AIF, using a reference tissue (RT) region. A direct estimation (rRTd) of relative parameters, based on the one-compartment model without using the AIF, was also obtained by using the kinetics inside the RT region. Results of test–retest studies show that absolute regional parameters have high CV, whatever the approach, with median values of about 30% for BV, and 40% for BF. The positive impact of normalization was established, showing a coherent estimation of relative parameters, with reduced CV (about 20% for BV and 30% for BF using the rRTd approach). These values were significantly lower ( p < 0.05) than the CV ofAbstract: Dynamic contrast-enhanced ultrasound has been proposed to monitor tumor therapy, as a complement to volume measurements. To assess the variability of perfusion parameters in ideal conditions, four consecutive test–retest studies were acquired in a mouse tumor model, using controlled injections. The impact of mathematical modeling on parameter variability was then investigated. Coefficients of variation (CV) of tissue blood volume (BV) and tissue blood flow (BF) based-parameters were estimated inside 32 sub-regions of the tumors, comparing the log-normal (LN) model with a one-compartment model fed by an arterial input function (AIF) and improved by the introduction of a time delay parameter. Relative perfusion parameters were also estimated by normalization of the LN parameters and normalization of the one-compartment parameters estimated with the AIF, using a reference tissue (RT) region. A direct estimation (rRTd) of relative parameters, based on the one-compartment model without using the AIF, was also obtained by using the kinetics inside the RT region. Results of test–retest studies show that absolute regional parameters have high CV, whatever the approach, with median values of about 30% for BV, and 40% for BF. The positive impact of normalization was established, showing a coherent estimation of relative parameters, with reduced CV (about 20% for BV and 30% for BF using the rRTd approach). These values were significantly lower ( p < 0.05) than the CV of absolute parameters. The rRTd approach provided the smallest CV and should be preferred for estimating relative perfusion parameters. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 62:Number 3(2017:Feb.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 62:Number 3(2017:Feb.)
- Issue Display:
- Volume 62, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 62
- Issue:
- 3
- Issue Sort Value:
- 2017-0062-0003-0000
- Page Start:
- 1113
- Page End:
- 1125
- Publication Date:
- 2017-01-16
- Subjects:
- dynamic contrast-enhanced ultrasound -- perfusion quantification -- reproducibility -- test–retest study -- compartmental model
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/aa54a3 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15035.xml