Evaluating the accuracy of a three-term pencil beam algorithm in heterogeneous media. (16th January 2017)
- Record Type:
- Journal Article
- Title:
- Evaluating the accuracy of a three-term pencil beam algorithm in heterogeneous media. (16th January 2017)
- Main Title:
- Evaluating the accuracy of a three-term pencil beam algorithm in heterogeneous media
- Authors:
- Chapman, J W
Knutson, N C
Fontenot, J D
Newhauser, W D
Hogstrom, K R - Abstract:
- Abstract: The goal of this work was to evaluate the accuracy of our in-house analytical dose calculation code against MCNPX data in heterogeneous phantoms. The analytical model utilizes a pencil beam model based on Fermi–Eyges theory to account for multiple Coulomb scattering and a least-squares fit to Monte Carlo data to account for nonelastic nuclear interactions as well as any remaining, uncharacterized scatter (the 'nuclear halo'). The model characterized dose accurately (up to 1% of maximum dose in broad fields (4 × 4 cm 2 and 10 × 10 cm 2 ) and up to 0.01% in a narrow field (0.1 × 0.1 cm 2 ) fit to MCNPX data). The accuracy of the model was benchmarked in three types of stylized phantoms: (1) homogeneous, (2) laterally infinite slab heterogeneities, and (3) laterally finite slab heterogeneities. Results from homogeneous phantoms and laterally infinite slab heterogeneities showed high levels of accuracy (>98% of points within 2% or 0.1 cm distance-to-agreement (DTA)). However, because range straggling and secondary particle production were not included in our model, central-axis dose differences of 2–4% were observed in laterally infinite slab heterogeneities when compared to Monte Carlo dose. In the presence of laterally finite slab heterogeneities, the analytical model resulted in lower pass rates (>96% of points within 2% or 0.1 cm DTA), which was attributed to the use of the central-axis approximation.
- Is Part Of:
- Physics in medicine & biology. Volume 62:Number 3(2017:Feb.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 62:Number 3(2017:Feb.)
- Issue Display:
- Volume 62, Issue 3 (2017)
- Year:
- 2017
- Volume:
- 62
- Issue:
- 3
- Issue Sort Value:
- 2017-0062-0003-0000
- Page Start:
- 1172
- Page End:
- 1191
- Publication Date:
- 2017-01-16
- Subjects:
- pencil beam algorithm -- nuclear halo -- proton -- dose calculation -- Monte Carlo -- MCNPX
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/aa51aa ↗