Hippocampal sparing radiotherapy in adults with primary brain tumours: a comparative planning and dosimetric study using IMPT, IMRT and 3DCRT. (12th October 2019)
- Record Type:
- Journal Article
- Title:
- Hippocampal sparing radiotherapy in adults with primary brain tumours: a comparative planning and dosimetric study using IMPT, IMRT and 3DCRT. (12th October 2019)
- Main Title:
- Hippocampal sparing radiotherapy in adults with primary brain tumours: a comparative planning and dosimetric study using IMPT, IMRT and 3DCRT.
- Authors:
- Patrice Aka, Fleman
Taylor, Roger
Hugtenburg, Richard
Lambert, Jamil
Powell, James - Abstract:
- Abstract: Introduction: We assessed the feasibility of hippocampal sparing in adults with primary brain tumours using Intensity Modulated Proton Therapy (IMPT) and compared this with Intensity Modulated Radiotherapy (IMRT) and 3D-Conformal Radiotherapy (3DCRT). Methods and Materials: 20 patients were identified, and each patient underwent a radiotherapy planning CT scan and 2 MRI scans. A pre-operative diagnostic MRI scan was fused with the planning CT and used for target delineation and a dedicated 3T MRI scan at the time of planning was fused with the CT for hippocampus delineation. 3 hippocampal sparing plans were generated for each patient with specific prescriptions (54Gy/30 fractions, 60Gy/30 fractions and 59.4Gy/33 fractions) using IMPT, IMRT and 3DCRT. Hippocampal sparing was defined as median dose to contralateral hippocampus ≤25Gy without compromising target coverage and organ at risk dose constraints. Results: Hippocampal sparing was achieved in 19 patients (95%) with IMPT, 16 patients (80%) with IMRT and 13 patients (65%) with 3DCRT. The largest median hippocampal dose reduction was seen with IMPT, with a mean median hippocampal dose of 4.8Gy (range: 0.0Gy-24.9Gy), 14.6Gy (range: 1.9Gy-21.7Gy), and 16.2Gy (range: 2.3Gy-25.0Gy) for IMPT, IMRT and 3DCRT respectively. Hippocampal sparing IMPT failed in one case with the largest tumour volume (650cc) where 2/3 of the hippocampus overlapped the target volume. Conclusion: IMPT as compared to IMRT and 3DCRT plans showedAbstract: Introduction: We assessed the feasibility of hippocampal sparing in adults with primary brain tumours using Intensity Modulated Proton Therapy (IMPT) and compared this with Intensity Modulated Radiotherapy (IMRT) and 3D-Conformal Radiotherapy (3DCRT). Methods and Materials: 20 patients were identified, and each patient underwent a radiotherapy planning CT scan and 2 MRI scans. A pre-operative diagnostic MRI scan was fused with the planning CT and used for target delineation and a dedicated 3T MRI scan at the time of planning was fused with the CT for hippocampus delineation. 3 hippocampal sparing plans were generated for each patient with specific prescriptions (54Gy/30 fractions, 60Gy/30 fractions and 59.4Gy/33 fractions) using IMPT, IMRT and 3DCRT. Hippocampal sparing was defined as median dose to contralateral hippocampus ≤25Gy without compromising target coverage and organ at risk dose constraints. Results: Hippocampal sparing was achieved in 19 patients (95%) with IMPT, 16 patients (80%) with IMRT and 13 patients (65%) with 3DCRT. The largest median hippocampal dose reduction was seen with IMPT, with a mean median hippocampal dose of 4.8Gy (range: 0.0Gy-24.9Gy), 14.6Gy (range: 1.9Gy-21.7Gy), and 16.2Gy (range: 2.3Gy-25.0Gy) for IMPT, IMRT and 3DCRT respectively. Hippocampal sparing IMPT failed in one case with the largest tumour volume (650cc) where 2/3 of the hippocampus overlapped the target volume. Conclusion: IMPT as compared to IMRT and 3DCRT plans showed a trend towards significant and effective hippocampal sparing in adult patients with primary brain tumours. We are currently evaluating this in a larger patient cohort and comparing IMPT with VMAT. … (more)
- Is Part Of:
- Neuro-oncology. Volume 21(2019)Supplement 4
- Journal:
- Neuro-oncology
- Issue:
- Volume 21(2019)Supplement 4
- Issue Display:
- Volume 21, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 21
- Issue:
- 4
- Issue Sort Value:
- 2019-0021-0004-0000
- Page Start:
- iv2
- Page End:
- iv3
- Publication Date:
- 2019-10-12
- Subjects:
- Brain Neoplasms -- Periodicals
Brain -- Tumors -- Periodicals
Brain -- Cancer -- Periodicals
Nervous system -- Cancer -- Periodicals
616.99481 - Journal URLs:
- http://neuro-oncology.dukejournals.org/ ↗
http://neuro-oncology.oxfordjournals.org/ ↗
http://www.oxfordjournals.org/content?genre=journal&issn=1522-8517 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/neuonc/noz167.008 ↗
- Languages:
- English
- ISSNs:
- 1522-8517
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.288000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15027.xml