Early Outcomes of Isolated Aortic Valve Replacement Through Right Anterior Minithoracotomy Using the Latest-Generation Biological Prosthesis. Issue 1 (January 2021)
- Record Type:
- Journal Article
- Title:
- Early Outcomes of Isolated Aortic Valve Replacement Through Right Anterior Minithoracotomy Using the Latest-Generation Biological Prosthesis. Issue 1 (January 2021)
- Main Title:
- Early Outcomes of Isolated Aortic Valve Replacement Through Right Anterior Minithoracotomy Using the Latest-Generation Biological Prosthesis
- Authors:
- Amirjamshidi, Hossein
Vidovich, Courtney
Goodman, Ariana
Knight, Peter A. - Abstract:
- Objective: The aim of this study is to evaluate early and intermediate outcomes and hemodynamics of the latest-generation Trifecta valve implanted using right anterior minithoracotomy. Methods: We performed a single-center, retrospective, observational study including 175 individuals who underwent isolated minimally invasive aortic valve replacement with the latest-generation Trifecta valves through a right anterior minithoracotomy between January 2016 and January 2019. Exclusion criteria for follow-up echocardiographic study included concomitant procedures, conversion to median sternotomy, and nonsurvival during the index admission. Analyses addressed implantation safety, 30-day and intermediate-term survival and hemodynamic performance of the valves. Results: Overall, patients were followed with duration ranging from 0.5 to 3 years. Early (<30 days) mortality occurred in 2 patients (1.1%), and there were 9 (5.1%) late (>30 days) deaths. Early thromboembolic events and postoperative bleeding requiring reoperation occurred at a rate of 4.0% ( n = 7) and 6.2% ( n = 11), respectively. Overall in 175 patients who met inclusion criteria for the follow-up echocardiography study, mean gradients across all valve sizes were 41.3 ± 14.9 (standard deviation) mm Hg preoperatively and remained low at 7.2 ± 3.9 mm Hg with mean effective orifice area of 1.8 ± 0.5 cm 2 on the last follow-up echo. There was 1 case of infective prosthetic endocarditis, which did not require valve explant.Objective: The aim of this study is to evaluate early and intermediate outcomes and hemodynamics of the latest-generation Trifecta valve implanted using right anterior minithoracotomy. Methods: We performed a single-center, retrospective, observational study including 175 individuals who underwent isolated minimally invasive aortic valve replacement with the latest-generation Trifecta valves through a right anterior minithoracotomy between January 2016 and January 2019. Exclusion criteria for follow-up echocardiographic study included concomitant procedures, conversion to median sternotomy, and nonsurvival during the index admission. Analyses addressed implantation safety, 30-day and intermediate-term survival and hemodynamic performance of the valves. Results: Overall, patients were followed with duration ranging from 0.5 to 3 years. Early (<30 days) mortality occurred in 2 patients (1.1%), and there were 9 (5.1%) late (>30 days) deaths. Early thromboembolic events and postoperative bleeding requiring reoperation occurred at a rate of 4.0% ( n = 7) and 6.2% ( n = 11), respectively. Overall in 175 patients who met inclusion criteria for the follow-up echocardiography study, mean gradients across all valve sizes were 41.3 ± 14.9 (standard deviation) mm Hg preoperatively and remained low at 7.2 ± 3.9 mm Hg with mean effective orifice area of 1.8 ± 0.5 cm 2 on the last follow-up echo. There was 1 case of infective prosthetic endocarditis, which did not require valve explant. There were no reoperations due to valve-related problems during the study period. Conclusions: This is the largest series reporting on outcomes of the latest-generation Trifecta valve implanted using right anterior minithoracotomy. Our results demonstrate that this valve can be safely implanted via a minimally invasive approach with excellent early and intermediate outcomes and hemodynamic performance. … (more)
- Is Part Of:
- Innovations. Volume 16:Issue 1(2021)
- Journal:
- Innovations
- Issue:
- Volume 16:Issue 1(2021)
- Issue Display:
- Volume 16, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2021-0016-0001-0000
- Page Start:
- 52
- Page End:
- 57
- Publication Date:
- 2021-01
- Subjects:
- aortic valve replacement -- minimally invasive surgery -- Trifecta valve -- latest-generation biological prosthesis
Cardiovascular system -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Thorax -- Chirurgie -- Méthodologie -- Périodiques
Vaisseaux sanguins -- Chirurgie -- Méthodologie -- Périodiques
Blood-vessels -- Surgery
Chest -- Surgery
Periodicals
617.41 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243895-000000000-00000 ↗
http://journals.lww.com/innovjournal/pages/default.aspx ↗
http://www.lww.com/product/?1556-9845 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1177/1556984520975889 ↗
- Languages:
- English
- ISSNs:
- 1556-9845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15025.xml