Intraoperative diagnosis of lymph node metastasis during segmentectomy for non‐small cell lung cancer by rapid immunohistochemistry using noncontact alternating current electric field mixing. Issue 12 (19th October 2020)
- Record Type:
- Journal Article
- Title:
- Intraoperative diagnosis of lymph node metastasis during segmentectomy for non‐small cell lung cancer by rapid immunohistochemistry using noncontact alternating current electric field mixing. Issue 12 (19th October 2020)
- Main Title:
- Intraoperative diagnosis of lymph node metastasis during segmentectomy for non‐small cell lung cancer by rapid immunohistochemistry using noncontact alternating current electric field mixing
- Authors:
- Imai, Kazuhiro
Nanjo, Hiroshi
Takashima, Shinogu
Hiroshima, Yuko
Atari, Maiko
Matsuo, Tsubasa
Kuriyama, Shoji
Ishii, Yoshiaki
Wakamatsu, Yuki
Sato, Yusuke
Motoyama, Satoru
Saito, Hajime
Nomura, Kyoko
Minamiya, Yoshihiro - Abstract:
- Abstract : Background: Although lobectomy is considered the standard surgery for any non‐small cell lung cancer (NSCLC), recent evidence indicates that for early NSCLCs segmentectomy may be equally effective. For segmentectomy to be oncologically safe, however, adequate intraoperative lymph node staging is essential. The aim of this study was to compare the results of a new rapid‐IHC system to the HE analysis for intraoperative nodal diagnosis in lung cancer patients considered for segmentectomy. Methods: This retrospective study analyzed the pathological reports from NSCLC resections over a six‐year period between 2014 and 2020. Using a new device for rapid‐IHC, we applied a high‐voltage, low‐frequency alternating current (AC) field, which mixes the antipancytokeratin antibody as the voltage is switched on/off. Rapid‐IHC can provide a nodal diagnosis within 20 minutes. Results: Frozen sections from 106 resected lymph nodes from 70 patients were intraoperatively evaluated for metastasis. Of those, five nodes were deemed positive based on both HE staining and rapid‐IHC. In addition, rapid‐IHC alone detected isolated tumor cells in one hilar lymph node. Three cStage IA patients with nodal metastasis detected with HE staining and rapid‐IHC received complete lobectomies. Five‐year relapse‐free survival and overall survival among patients receiving segmentectomy with rapid‐IHC were 88.77% and 88.79%, respectively. Conclusions: Rapid‐IHC driven by AC mixing is simple, highlyAbstract : Background: Although lobectomy is considered the standard surgery for any non‐small cell lung cancer (NSCLC), recent evidence indicates that for early NSCLCs segmentectomy may be equally effective. For segmentectomy to be oncologically safe, however, adequate intraoperative lymph node staging is essential. The aim of this study was to compare the results of a new rapid‐IHC system to the HE analysis for intraoperative nodal diagnosis in lung cancer patients considered for segmentectomy. Methods: This retrospective study analyzed the pathological reports from NSCLC resections over a six‐year period between 2014 and 2020. Using a new device for rapid‐IHC, we applied a high‐voltage, low‐frequency alternating current (AC) field, which mixes the antipancytokeratin antibody as the voltage is switched on/off. Rapid‐IHC can provide a nodal diagnosis within 20 minutes. Results: Frozen sections from 106 resected lymph nodes from 70 patients were intraoperatively evaluated for metastasis. Of those, five nodes were deemed positive based on both HE staining and rapid‐IHC. In addition, rapid‐IHC alone detected isolated tumor cells in one hilar lymph node. Three cStage IA patients with nodal metastasis detected with HE staining and rapid‐IHC received complete lobectomies. Five‐year relapse‐free survival and overall survival among patients receiving segmentectomy with rapid‐IHC were 88.77% and 88.79%, respectively. Conclusions: Rapid‐IHC driven by AC mixing is simple, highly accurate, and preserves nodal tissue for subsequent tests. This system can be used effectively for intraoperative nodal diagnosis. Rapid immunohistochemistry based on alternating‐current field mixing (completed within 20 minutes) is simple and highly accurate. This system will assist clinicians when making intraoperative diagnoses of lymph node metastasis and deciding upon the appropriate surgical procedure in segmentectomy for lung cancer. Key points: Significant findings of the study: Rapid immunohistochemistry driven by alternating‐current field mixing (completed within 20 minutes intraoperatively) is simple, highly accurate, and preserves lymph node tissue for subsequent pathological examination, including molecular assessments. What this study adds: Segmentectomy for lung cancer is oncologically safe, but only when there is adequate intraoperative node staging. Rapid immunohistochemistry will assist clinicians when making intraoperative nodal diagnoses. Abstract : Rapid immunohistochemistry based on alternating‐current field mixing (completed within 20 minutes) is simple and highly accurate. This system will assist clinicians when making intraoperative diagnoses of lymph node metastasis and deciding upon the appropriate surgical procedure in segmentectomy for lung cancer. … (more)
- Is Part Of:
- Thoracic cancer. Volume 11:Issue 12(2020)
- Journal:
- Thoracic cancer
- Issue:
- Volume 11:Issue 12(2020)
- Issue Display:
- Volume 11, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 11
- Issue:
- 12
- Issue Sort Value:
- 2020-0011-0012-0000
- Page Start:
- 3547
- Page End:
- 3554
- Publication Date:
- 2020-10-19
- Subjects:
- Intraoperative diagnosis -- lung cancer -- lymph node metastasis -- rapid immunohistochemistry -- segmentectomy
Chest -- Cancer -- Periodicals
Chest -- Cancer -- Treatment -- Periodicals
Chest -- Surgery -- Periodicals
616.99494005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/%28ISSN%291759-7714;jsessionid=9202029487E02D838DF722140677202D.d04t01 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1759-7714 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.wiley.com/bw/journal.asp?ref=1759-7706&site=1 ↗ - DOI:
- 10.1111/1759-7714.13699 ↗
- Languages:
- English
- ISSNs:
- 1759-7706
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8820.242500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15019.xml