One‐stop hybrid procedure combining catheter ablation and left atrial appendage closure increases long‐term risk for adverse events in patients with atrial fibrillation. Issue 11 (10th October 2020)
- Record Type:
- Journal Article
- Title:
- One‐stop hybrid procedure combining catheter ablation and left atrial appendage closure increases long‐term risk for adverse events in patients with atrial fibrillation. Issue 11 (10th October 2020)
- Main Title:
- One‐stop hybrid procedure combining catheter ablation and left atrial appendage closure increases long‐term risk for adverse events in patients with atrial fibrillation
- Authors:
- Li, Xue‐Xun
Tian, Ying
Shi, Liang
Wang, Yan‐Jiang
Zeng, Li‐Jun
Huang, Li‐Hong
He, Shu‐Nan
Li, Jian‐Ping
Liu, Xing‐Peng - Abstract:
- Abstract: Introduction: Combined catheter ablation (CA) and left atrial appendage closure (LAAC) have proven to be a feasible and safe strategy in treating patients with nonvalvular atrial fibrillation (AF). However, the interactions between CA and LAAC have not been systematically explored. We analyzed the impact of CA on long‐term outcomes of LAAC in patients with AF treated with the hybrid procedure. Methods: A total of 107 consecutive patients with AF who underwent LAAC were divided into two groups: group A (n = 61) included patients who underwent CA followed by LAAC during the same procedure and group B (n = 46) included patients who underwent LAAC only. All patients underwent systematic transesophageal echocardiography (TEE) follow‐up. Results: In group A, CA resulted in severe edema of the left atrial ridge (LAR), which manifested as an increase in LAR thickness from 4.6 ± 0.4 mm before CA to 6.8 ± 0.6 mm ( P < .01) after CA. TEE at 45 days showed that the incidence of peri‐device leakage was significantly higher in group A than in group B (45.9% vs 4.3%, P < .001). At the 12‐month follow‐up, the peri‐device leakage rate remained higher in group A than in group B (14.8% vs 2.2%, P < .01). Three (4.9%) patients in group A experienced transient ischemia attacks; no events were reported in group B during the 1‐year follow‐up. Conclusion: Edema of LAR with the single‐stage procedure that consists of CA followed by LAAC could result in increased peri‐device leakage andAbstract: Introduction: Combined catheter ablation (CA) and left atrial appendage closure (LAAC) have proven to be a feasible and safe strategy in treating patients with nonvalvular atrial fibrillation (AF). However, the interactions between CA and LAAC have not been systematically explored. We analyzed the impact of CA on long‐term outcomes of LAAC in patients with AF treated with the hybrid procedure. Methods: A total of 107 consecutive patients with AF who underwent LAAC were divided into two groups: group A (n = 61) included patients who underwent CA followed by LAAC during the same procedure and group B (n = 46) included patients who underwent LAAC only. All patients underwent systematic transesophageal echocardiography (TEE) follow‐up. Results: In group A, CA resulted in severe edema of the left atrial ridge (LAR), which manifested as an increase in LAR thickness from 4.6 ± 0.4 mm before CA to 6.8 ± 0.6 mm ( P < .01) after CA. TEE at 45 days showed that the incidence of peri‐device leakage was significantly higher in group A than in group B (45.9% vs 4.3%, P < .001). At the 12‐month follow‐up, the peri‐device leakage rate remained higher in group A than in group B (14.8% vs 2.2%, P < .01). Three (4.9%) patients in group A experienced transient ischemia attacks; no events were reported in group B during the 1‐year follow‐up. Conclusion: Edema of LAR with the single‐stage procedure that consists of CA followed by LAAC could result in increased peri‐device leakage and decreased compression rate over time, which may be also associated with elevated risk profiles when compared with an LAAC‐only procedure. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 43:Issue 11(2020)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 43:Issue 11(2020)
- Issue Display:
- Volume 43, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 43
- Issue:
- 11
- Issue Sort Value:
- 2020-0043-0011-0000
- Page Start:
- 1358
- Page End:
- 1365
- Publication Date:
- 2020-10-10
- Subjects:
- atrial fibrillation -- catheter ablation -- left atrial appendage closure -- left atrial ridge edema -- peri‐device leakage
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.14084 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15015.xml