SERS and electrochemical impedance spectroscopy immunoassay for carcinoembryonic antigen. (10th January 2021)
- Record Type:
- Journal Article
- Title:
- SERS and electrochemical impedance spectroscopy immunoassay for carcinoembryonic antigen. (10th January 2021)
- Main Title:
- SERS and electrochemical impedance spectroscopy immunoassay for carcinoembryonic antigen
- Authors:
- Castaño-Guerrero, Yuselis
Moreira, Felismina T. C.
Sousa-Castillo, Ana
Correa-Duarte, Miguel A.
Sales, M. Goreti F. - Abstract:
- Highlights: Combining electrochemical and surface enhanced Raman spectroscopy in the same spot. Immunosensor for CEA, assembled on a gold screen-printed electrode. First reading is of electrochemical nature, and followed by an iron redox probe. Second reading is obtained after antibody binding with the Raman reporter 4-aminothiophenol. Dual-signals of different nature allows one to double check the analytical result, with expected improvement of the accuracy. Abstract: This work describes an innovative dual detection approach, combining electrochemical and surface-enhanced Raman scattering (SERS) sequential readings, on the same sensing surface. This was achieved by establishing (i) an antibody binding stage on a suitably modified screen-printed electrode (Au-SPE), to produce an electrochemical signalling system, followed by (ii) a second antibody binding stage, on the same sensing surface, comprising gold nanostars (AuNS) with a suitable Raman reporter, and acting as a second signalling system (SERS). This simple principle is applied herein to carcinoembryonic antigen (CEA) detection. The first layer of antibodies was assembled on the Au-SPE previously modified with a cysteamine layer. Binding to CEA was allowed for 30 min. Electrochemical impedance spectroscopy (EIS) readings followed the several stages of Au-SPE modification and generated analytical data. After, the AuNS were modified with 4-aminothiophenol (4-ATP)/Ab-CEA, and incubated on the same sensing surface, toHighlights: Combining electrochemical and surface enhanced Raman spectroscopy in the same spot. Immunosensor for CEA, assembled on a gold screen-printed electrode. First reading is of electrochemical nature, and followed by an iron redox probe. Second reading is obtained after antibody binding with the Raman reporter 4-aminothiophenol. Dual-signals of different nature allows one to double check the analytical result, with expected improvement of the accuracy. Abstract: This work describes an innovative dual detection approach, combining electrochemical and surface-enhanced Raman scattering (SERS) sequential readings, on the same sensing surface. This was achieved by establishing (i) an antibody binding stage on a suitably modified screen-printed electrode (Au-SPE), to produce an electrochemical signalling system, followed by (ii) a second antibody binding stage, on the same sensing surface, comprising gold nanostars (AuNS) with a suitable Raman reporter, and acting as a second signalling system (SERS). This simple principle is applied herein to carcinoembryonic antigen (CEA) detection. The first layer of antibodies was assembled on the Au-SPE previously modified with a cysteamine layer. Binding to CEA was allowed for 30 min. Electrochemical impedance spectroscopy (EIS) readings followed the several stages of Au-SPE modification and generated analytical data. After, the AuNS were modified with 4-aminothiophenol (4-ATP)/Ab-CEA, and incubated on the same sensing surface, to provide SERS data. The analytical features were checked for both EIS and SERS. In EIS, the sensor showed linear response range from 0.25 to 250 ng/mL, with a linear correlation coefficient of 0.991, evaluated in serum. It also demonstrated good selectivity against creatinine and glucose. Using the SERS as signalling system, the spectra confirmed differentiated signals from the background within 0.025 ng/mL to 250 ng/mL of CEA. As expected, the Raman signal of the reporter increased with increasing CEA concentrations, and contributed to confirm the accuracy of the analytical data. Overall, this approach is simple, and may be adaptable to new multiplexing devices, also being adaptable to mass production. … (more)
- Is Part Of:
- Electrochimica acta. Volume 366(2021)
- Journal:
- Electrochimica acta
- Issue:
- Volume 366(2021)
- Issue Display:
- Volume 366, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 366
- Issue:
- 2021
- Issue Sort Value:
- 2021-0366-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01-10
- Subjects:
- Carcinoembryonic antigen -- Immunosensor -- Electrochemical impedance spectroscopy -- Screen-printed electrode -- Surface-enhanced Raman spectroscopy
Electrochemistry -- Periodicals
Electrochemistry, Industrial -- Periodicals
541.37 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00134686 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.electacta.2020.137377 ↗
- Languages:
- English
- ISSNs:
- 0013-4686
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.950000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14990.xml