Gait regularity assessed by wearable sensors: Comparison between accelerometer and gyroscope data for different sensor locations and walking speeds in healthy subjects. (2nd December 2020)
- Record Type:
- Journal Article
- Title:
- Gait regularity assessed by wearable sensors: Comparison between accelerometer and gyroscope data for different sensor locations and walking speeds in healthy subjects. (2nd December 2020)
- Main Title:
- Gait regularity assessed by wearable sensors: Comparison between accelerometer and gyroscope data for different sensor locations and walking speeds in healthy subjects
- Authors:
- Scalera, Giovanni Marco
Ferrarin, Maurizio
Rabuffetti, Marco - Abstract:
- Abstract: Inertial measurement units (IMU), including accelerometers and gyroscopes, can support the assessment of gait regularity, relevant for an effective walking. Gait regularity is typically quantified by an autocorrelation analysis of trunk/pelvis accelerations. A methodological upgrade fosters a multi-sensor approach including upper and lower limbs. Very few studies dealt with gait regularity using gyroscope data and no comparison between the two inertial sensors has been published. Therefore, this study compares gait regularity assessment by autocorrelation analyses performed on accelerometer and gyroscope data simultaneously acquired. Twenty-five adult healthy subjects walked steady-state on treadmill at three speeds (3.6, 5.0, 6.4 km/h), with rest between. Four IMUs were firmly attached on the trunk, pelvis, wrist and ankle. The autocorrelation method was applied to time-windows of the signal vector magnitude and resulted, on average for each trial, in its regularity index (RI) and periodicity index (PI), i.e. the stride time. Results showed that both sensors identified the same PI (Spearman correlation coefficient = 0.999), and evidenced that, for matched sensor locations and gait speeds, the accelerometer-based RI was larger/equal to the gyroscope-based RI on 86.3% of all conditions (overall median of gyroscope-to-accelerometer RI ratio was 91.1%). The two sensors gave always statistically different RI, with the exception of the ankle at the lowest speed andAbstract: Inertial measurement units (IMU), including accelerometers and gyroscopes, can support the assessment of gait regularity, relevant for an effective walking. Gait regularity is typically quantified by an autocorrelation analysis of trunk/pelvis accelerations. A methodological upgrade fosters a multi-sensor approach including upper and lower limbs. Very few studies dealt with gait regularity using gyroscope data and no comparison between the two inertial sensors has been published. Therefore, this study compares gait regularity assessment by autocorrelation analyses performed on accelerometer and gyroscope data simultaneously acquired. Twenty-five adult healthy subjects walked steady-state on treadmill at three speeds (3.6, 5.0, 6.4 km/h), with rest between. Four IMUs were firmly attached on the trunk, pelvis, wrist and ankle. The autocorrelation method was applied to time-windows of the signal vector magnitude and resulted, on average for each trial, in its regularity index (RI) and periodicity index (PI), i.e. the stride time. Results showed that both sensors identified the same PI (Spearman correlation coefficient = 0.999), and evidenced that, for matched sensor locations and gait speeds, the accelerometer-based RI was larger/equal to the gyroscope-based RI on 86.3% of all conditions (overall median of gyroscope-to-accelerometer RI ratio was 91.1%). The two sensors gave always statistically different RI, with the exception of the ankle at the lowest speed and wrist at higher speeds. Such results help remove potential confounders from analyses performed with different sensors and support the use of accelerometers for gait regularity assessment, not excluding that gyroscopes may be more suitable for other human movements. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 113(2020)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 113(2020)
- Issue Display:
- Volume 113, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 113
- Issue:
- 2020
- Issue Sort Value:
- 2020-0113-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12-02
- Subjects:
- Accelerometer -- Gyroscope -- Regularity -- Gait -- Rehabilitation -- Motor functions
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2020.110115 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14985.xml