The equine diaphragm: A novel technique for repeatable ultrasound measurement. Issue 6 (17th August 2020)
- Record Type:
- Journal Article
- Title:
- The equine diaphragm: A novel technique for repeatable ultrasound measurement. Issue 6 (17th August 2020)
- Main Title:
- The equine diaphragm: A novel technique for repeatable ultrasound measurement
- Authors:
- Fitzharris, Laura E.
Meehan, Lucinda J.
Hezzell, Melanie J.
Allen, Kate J. - Abstract:
- Abstract: The diaphragm is an important respiratory muscle, playing a key role during exercise. In humans, diaphragm thickness increases in response to training and is correlated with inspiratory strength. In order to assess respiratory strength in the horse, new evaluation techniques are required and measurement of diaphragm thickness, in a non‐invasive and repeatable manner, is a possible approach. The purposes of this four‐part, prospective, pilot study were to develop and describe a repeatable method to measure the diaphragm thickness, using ultrasonography, in Thoroughbred racehorses. A standardized technique was developed whereby the ultrasound transducer was positioned 1 cm below a line between the cranioventral aspect of the tuber coxae and olecranon. The diaphragm thickness was measured on three occasions 1 week apart, by a single observer to determine the intraobserver repeatability, and by a second observer on one occasion to assess interobserver reproducibility. The diaphragm was observed in all intercostal spaces (ICS) from 7 to 17 on the left side, and 6 to 17 on the right side in a single horse. The thickest measurement (1.42 cm), obtained from 11 horses, was at ICS 11 on the left‐side during inspiration. The narrowest measurement (0.56 cm) was obtained at ICS 16 on the right‐side during expiration. There was no significant difference between the measurements obtained by a single observer on three occasions ( P < .05). This is the first study to provide aAbstract: The diaphragm is an important respiratory muscle, playing a key role during exercise. In humans, diaphragm thickness increases in response to training and is correlated with inspiratory strength. In order to assess respiratory strength in the horse, new evaluation techniques are required and measurement of diaphragm thickness, in a non‐invasive and repeatable manner, is a possible approach. The purposes of this four‐part, prospective, pilot study were to develop and describe a repeatable method to measure the diaphragm thickness, using ultrasonography, in Thoroughbred racehorses. A standardized technique was developed whereby the ultrasound transducer was positioned 1 cm below a line between the cranioventral aspect of the tuber coxae and olecranon. The diaphragm thickness was measured on three occasions 1 week apart, by a single observer to determine the intraobserver repeatability, and by a second observer on one occasion to assess interobserver reproducibility. The diaphragm was observed in all intercostal spaces (ICS) from 7 to 17 on the left side, and 6 to 17 on the right side in a single horse. The thickest measurement (1.42 cm), obtained from 11 horses, was at ICS 11 on the left‐side during inspiration. The narrowest measurement (0.56 cm) was obtained at ICS 16 on the right‐side during expiration. There was no significant difference between the measurements obtained by a single observer on three occasions ( P < .05). This is the first study to provide a detailed description of ultrasonographic imaging and measurement of the equine diaphragm. The novel technique developed to position the ultrasound transducer in a standardized location allowed examination and measurement of the diaphragm with good repeatability. … (more)
- Is Part Of:
- Veterinary radiology & ultrasound. Volume 61:Issue 6(2020)
- Journal:
- Veterinary radiology & ultrasound
- Issue:
- Volume 61:Issue 6(2020)
- Issue Display:
- Volume 61, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 61
- Issue:
- 6
- Issue Sort Value:
- 2020-0061-0006-0000
- Page Start:
- 705
- Page End:
- 717
- Publication Date:
- 2020-08-17
- Subjects:
- diaphragm thickness -- horse -- respiratory muscle -- respiratory strength -- ultrasound
Veterinary radiology -- Periodicals
Radiologie vétérinaire -- Périodiques
Échographie vétérinaire -- Périodiques
Radiography -- Periodicals
Ultrasonography -- Periodicals
Diagnosis -- Periodicals
Veterinary Medicine -- Periodicals
Societies, Medical -- Periodicals
636.089607 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1740-8261 ↗
http://www.blackwell-synergy.com/loi/vru ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1058-8183;screen=info;ECOIP ↗
http://www.blackwell-synergy.com/loi/vru ↗ - DOI:
- 10.1111/vru.12903 ↗
- Languages:
- English
- ISSNs:
- 1058-8183
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9229.281000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14975.xml