Sub-detector unit timing calibration for brain PET based on L1-norm constraint. (3rd May 2016)
- Record Type:
- Journal Article
- Title:
- Sub-detector unit timing calibration for brain PET based on L1-norm constraint. (3rd May 2016)
- Main Title:
- Sub-detector unit timing calibration for brain PET based on L1-norm constraint
- Authors:
- Yu, Xingjian
Isobe, Takashi
Watanabe, Mitsuo
Liu, Huafeng - Abstract:
- Abstract: A novel sub-detector unit timing calibration method using iterative shrinkage-thresholding (IST) has been developed for a high-resolution brain positron emission tomography (PET) system, which uses a four-layer depth of interaction detector. The timing calibration process is formulated into a linear problem in the proposed method. To obtain a low-variance and robust estimation, an L1-norm constraint is added in the linear equation. Moreover, the detector unit segmentation in the detectors is used to achieve a sub-detector unit level timing calibration. No special source or additional detector element is required for the timing calibration. It is shown that the measured data set from a normal cylindrical phantom filled with radioisotope solution is sufficient for performing a high-precision timing calibration. This method is suitable for PET systems with a large number of crystal elements. In this paper, both simulation and real scanning data were used to demonstrate the effectiveness and robustness of the sub-detector unit level IST method. The timing resolution of a 22 Na point source placed at the center of the field of view in the brain PET system was evaluated using different timing calibration methods, along with the optimal selection of detector unit segmentation, to validate the IST method. The timing resolution was improved from 3.34 ns (at full width at half maximum (FWHM)) to 2.54 ns (FWHM) through implementing the IST and the detector unit segmentation.
- Is Part Of:
- Biomedical physics & engineering express. Volume 2:Number 3(2016)
- Journal:
- Biomedical physics & engineering express
- Issue:
- Volume 2:Number 3(2016)
- Issue Display:
- Volume 2, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 2
- Issue:
- 3
- Issue Sort Value:
- 2016-0002-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-05-03
- Subjects:
- PET -- timing calibration -- L1-norm -- detector unit segmentation -- iterative shrinkage-thresholding
Medical physics -- Periodicals
Biophysics -- Periodicals
Biomedical engineering -- Periodicals
Medical sciences -- Periodicals
610.153 - Journal URLs:
- http://iopscience.iop.org/2057-1976/ ↗
http://www.iop.org/ ↗ - DOI:
- 10.1088/2057-1976/2/3/035008 ↗
- Languages:
- English
- ISSNs:
- 2057-1976
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14978.xml