Noise dependency in vascular parameters from combined gradient-echo and spin-echo DSC MRI. (13th November 2020)
- Record Type:
- Journal Article
- Title:
- Noise dependency in vascular parameters from combined gradient-echo and spin-echo DSC MRI. (13th November 2020)
- Main Title:
- Noise dependency in vascular parameters from combined gradient-echo and spin-echo DSC MRI
- Authors:
- Digernes, Ingrid
Nilsen, Line B
Grøvik, Endre
Bjørnerud, Atle
Løvland, Grethe
Vik-Mo, Einar
Meling, Torstein R
Saxhaug, Cathrine
Helland, Åslaug
Jacobsen, Kari D
Geier, Oliver
Emblem, Kyrre E - Abstract:
- Abstract: Dynamic susceptibility contrast (DSC) imaging is a widely used technique for assessment of cerebral blood volume (CBV). With combined gradient-echo and spin-echo DSC techniques, measures of the underlying vessel size and vessel architecture can be obtained from the vessel size index (VSI) and vortex area, respectively. However, how noise, and specifically the contrast-to-noise ratio (CNR), affect the estimations of these parameters has largely been overlooked. In order to address this issue, we have performed simulations to generate DSC signals with varying levels of CNR, defined by the peak of relaxation rate curve divided by the standard deviation of the baseline. Moreover, DSC data from 59 brain cancer patients were acquired at two different 3 T-scanners (N = 29 and N = 30, respectively), where CNR and relative parameter maps were obtained. Our simulations showed that the measured parameters were affected by CNR in different ways, where low CNR led to overestimations of CBV and underestimations of VSI and vortex area. In addition, a higher noise-sensitivity was found in vortex area than in CBV and VSI. Results from clinical data were consistent with simulations, and indicated that CNR < 4 gives highly unreliable measurements. Moreover, we have shown that the distribution of values in the tumour regions could change considerably when voxels with CNR below a given cut off are excluded when generating the relative parameter maps. The widespread use of CBV andAbstract: Dynamic susceptibility contrast (DSC) imaging is a widely used technique for assessment of cerebral blood volume (CBV). With combined gradient-echo and spin-echo DSC techniques, measures of the underlying vessel size and vessel architecture can be obtained from the vessel size index (VSI) and vortex area, respectively. However, how noise, and specifically the contrast-to-noise ratio (CNR), affect the estimations of these parameters has largely been overlooked. In order to address this issue, we have performed simulations to generate DSC signals with varying levels of CNR, defined by the peak of relaxation rate curve divided by the standard deviation of the baseline. Moreover, DSC data from 59 brain cancer patients were acquired at two different 3 T-scanners (N = 29 and N = 30, respectively), where CNR and relative parameter maps were obtained. Our simulations showed that the measured parameters were affected by CNR in different ways, where low CNR led to overestimations of CBV and underestimations of VSI and vortex area. In addition, a higher noise-sensitivity was found in vortex area than in CBV and VSI. Results from clinical data were consistent with simulations, and indicated that CNR < 4 gives highly unreliable measurements. Moreover, we have shown that the distribution of values in the tumour regions could change considerably when voxels with CNR below a given cut off are excluded when generating the relative parameter maps. The widespread use of CBV and attractive potential of VSI and vortex area, makes the noise-sensitivity of these parameters found in our study relevant for further use and development of the DSC imaging technique. Our results suggest that the CNR has considerable impact on the measured parameters, with the potential to affect the clinical interpretation of DSC-MRI, and should therefore be taken into account in the clinical decision-making process. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 65:Number 22(2020:Nov.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 65:Number 22(2020:Nov.)
- Issue Display:
- Volume 65, Issue 22 (2020)
- Year:
- 2020
- Volume:
- 65
- Issue:
- 22
- Issue Sort Value:
- 2020-0065-0022-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-13
- Subjects:
- dynamic susceptibility contrast (DSC) -- neuro-oncology -- perfusion MRI -- vascular modelling -- vessel architectural imaging -- vessel size imaging -- mathematical modelling
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/abb71a ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14969.xml