Quality evaluation of signals collected by portable ECG devices using dimensionality reduction and flexible model integration. (3rd November 2020)
- Record Type:
- Journal Article
- Title:
- Quality evaluation of signals collected by portable ECG devices using dimensionality reduction and flexible model integration. (3rd November 2020)
- Main Title:
- Quality evaluation of signals collected by portable ECG devices using dimensionality reduction and flexible model integration
- Authors:
- Zhu, Zeyang
Li, Jianhua
Zhang, Shuang
Geng, Ning
Xu, Lisheng
Greenwald, Stephen E - Abstract:
- Abstract: Objective : Portable devices for collecting electrocardiograms (ECGs) and telemedicine systems for diagnosis are available to residents in deprived areas, but ECGs collected by non-professionals are not necessarily reliable and may impair the accuracy of diagnosis. We propose an algorithm for accurate ECG quality assessment, which can help improve the reliability of ECGs collected by portable devices. Approach : Using challenge data from CinC (2019), signals were classified as 'acceptable' and 'unacceptable' by annotators. The training set contained 998 12-lead ECGs and the test set contained 500. A 998 × 84 feature matrix, S, was formed by feature extraction and three basic models were obtained through training SVM, DT and NBC on S . The feature subsets S1, S2 and S3 were obtained by dimensionality reduction on S using SVM, DT and NBC, respectively. Three other basic models were obtained through training SVM on S1, DT on S2 and NBC on S3 . By combining these six basic models, several integrated models were formed. An iterative method was proposed to select the integrated model with the highest accuracy on the training set. Having compared differences between the output labels and the original data labels, evaluation criteria were calculated. Main results : An accuracy of 98.70% and 98.60% was achieved on the training and test datasets, respectively. High F1 score and Kappa values were also obtained. Significance : The proposed algorithm has advantages overAbstract: Objective : Portable devices for collecting electrocardiograms (ECGs) and telemedicine systems for diagnosis are available to residents in deprived areas, but ECGs collected by non-professionals are not necessarily reliable and may impair the accuracy of diagnosis. We propose an algorithm for accurate ECG quality assessment, which can help improve the reliability of ECGs collected by portable devices. Approach : Using challenge data from CinC (2019), signals were classified as 'acceptable' and 'unacceptable' by annotators. The training set contained 998 12-lead ECGs and the test set contained 500. A 998 × 84 feature matrix, S, was formed by feature extraction and three basic models were obtained through training SVM, DT and NBC on S . The feature subsets S1, S2 and S3 were obtained by dimensionality reduction on S using SVM, DT and NBC, respectively. Three other basic models were obtained through training SVM on S1, DT on S2 and NBC on S3 . By combining these six basic models, several integrated models were formed. An iterative method was proposed to select the integrated model with the highest accuracy on the training set. Having compared differences between the output labels and the original data labels, evaluation criteria were calculated. Main results : An accuracy of 98.70% and 98.60% was achieved on the training and test datasets, respectively. High F1 score and Kappa values were also obtained. Significance : The proposed algorithm has advantages over previously reported approaches during automatic assessment of ECG quality and can thus help to reduce reliance on highly trained professionals when assessing the quality of ECGs. … (more)
- Is Part Of:
- Physiological measurement. Volume 41:Number 10(2020)
- Journal:
- Physiological measurement
- Issue:
- Volume 41:Number 10(2020)
- Issue Display:
- Volume 41, Issue 10 (2020)
- Year:
- 2020
- Volume:
- 41
- Issue:
- 10
- Issue Sort Value:
- 2020-0041-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-03
- Subjects:
- ECG quality assessment -- portable devices -- telemedicine -- dimensionality reduction -- integrated model
Physiology -- Measurement -- Periodicals
Patient monitoring -- Periodicals
612 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0967-3334 ↗ - DOI:
- 10.1088/1361-6579/abba0b ↗
- Languages:
- English
- ISSNs:
- 0967-3334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14969.xml