P1470Outcome of leadless pacemaker implantation in a referral centre for lead extraction: a comparison with transvenous pacemaker. (18th June 2020)
- Record Type:
- Journal Article
- Title:
- P1470Outcome of leadless pacemaker implantation in a referral centre for lead extraction: a comparison with transvenous pacemaker. (18th June 2020)
- Main Title:
- P1470Outcome of leadless pacemaker implantation in a referral centre for lead extraction: a comparison with transvenous pacemaker
- Authors:
- Tolve, S
Zucchelli, G
Barletta, V
Parollo, M
Di Cori, A
Della Tommasina, V
De Lucia, R
Giannotti Santoro, M
Mazzocchetti, L
Cellamaro, T
Viani, S
Segreti, L
Paperini, L
Soldati, E
Bongiorni, M G - Abstract:
- Abstract: Background: Leadless cardiac pacing is a promising technology in terms of efficacy and safety. Purpose: The aim of the study was to compare the long-term clinical and electrical performance of Micra leadless pacemaker with ventricular single-chamber transvenous pacemaker (VVI TV-PM) in a high-volume centre for transvenous lead extraction (TLE). Methods: Between May 2014 and April 2019, 100 patients (group 1) underwent Micra implant at our centre. We identified 100 patients (group 2) who underwent VVI TV-PM implant in the same period for a 1:1 comparison matched by age, sex, left ventricular systolic ejection fraction and previous TLE. Results: The implant procedure was successful in all patients. In group 1, the procedure duration was lower than in group 2 (43.86 ± 22.38 vs 58.38 ± 17.85 min, p < 0.001), while the fluoroscopy time was longer (12.25 ± 6.84 vs 5.32 ± 4.42 min, p < 0.001). There was no difference about the rate of septal deployment at the right ventricle (group 1 vs group 2: 76% vs 86%, p = 0.10). Patients were followed-up for a median of 12 months. We did not observe any acute and chronic procedure-related complications in group 1, while we reported acute complications in seven patients (0 vs 7%, p = 0.02) and long-term complications in three patients (0 vs 3%, p = 0.24), needing for a system revisions in 6 cases (0 vs 6%, p = 0.038) in group 2. One systemic infection occurred during follow-up in a patient with VVI TV-PM. Electrical measurementsAbstract: Background: Leadless cardiac pacing is a promising technology in terms of efficacy and safety. Purpose: The aim of the study was to compare the long-term clinical and electrical performance of Micra leadless pacemaker with ventricular single-chamber transvenous pacemaker (VVI TV-PM) in a high-volume centre for transvenous lead extraction (TLE). Methods: Between May 2014 and April 2019, 100 patients (group 1) underwent Micra implant at our centre. We identified 100 patients (group 2) who underwent VVI TV-PM implant in the same period for a 1:1 comparison matched by age, sex, left ventricular systolic ejection fraction and previous TLE. Results: The implant procedure was successful in all patients. In group 1, the procedure duration was lower than in group 2 (43.86 ± 22.38 vs 58.38 ± 17.85 min, p < 0.001), while the fluoroscopy time was longer (12.25 ± 6.84 vs 5.32 ± 4.42 min, p < 0.001). There was no difference about the rate of septal deployment at the right ventricle (group 1 vs group 2: 76% vs 86%, p = 0.10). Patients were followed-up for a median of 12 months. We did not observe any acute and chronic procedure-related complications in group 1, while we reported acute complications in seven patients (0 vs 7%, p = 0.02) and long-term complications in three patients (0 vs 3%, p = 0.24), needing for a system revisions in 6 cases (0 vs 6%, p = 0.038) in group 2. One systemic infection occurred during follow-up in a patient with VVI TV-PM. Electrical measurements were stable during follow-up in both groups, with a longer estimated battery life in group 1 (mean delivered energy at implant group 1 vs group 2: 0.14 ± 0.21 vs 0.26 ± 0.22 μJ, p < 0.001). Conclusion: Micra pacemaker implant is a safe and effective procedure, with a lower rate of acute complications and system revisions and a longer estimated battery life compared to VVI TV-PM, even in a real life setting including patients who underwent TLE. … (more)
- Is Part Of:
- Europace. Volume 22(2020)Supplement 1
- Journal:
- Europace
- Issue:
- Volume 22(2020)Supplement 1
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06-18
- Subjects:
- Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa162.131 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14961.xml