Blood flow patterns estimation in the left ventricle with low-rate 2D and 3D dynamic contrast-enhanced ultrasound. (January 2021)
- Record Type:
- Journal Article
- Title:
- Blood flow patterns estimation in the left ventricle with low-rate 2D and 3D dynamic contrast-enhanced ultrasound. (January 2021)
- Main Title:
- Blood flow patterns estimation in the left ventricle with low-rate 2D and 3D dynamic contrast-enhanced ultrasound
- Authors:
- Chen, Peiran
van Sloun, Ruud J.G.
Turco, Simona
Wijkstra, Hessel
Filomena, Domenico
Agati, Luciano
Houthuizen, Patrick
Mischi, Massimo - Abstract:
- Highlights: Cardiac diagnostics may benefit from blood flow-pattern analysis. Current techniques for the visualization of blood flow patterns requires high acquisition rates. The employment of low acquisition rate DCE-US facilitates the clinical adaption of the method using standard ultrasound scanners. 2D and 3D velocity vector fields in the left ventricle are demonstrated and analyzed. Abstract: Background and Objective : Left ventricle (LV) dysfunction always occurs at early heart-failure stages, producing variations in the LV flow patterns. Cardiac diagnostics may therefore benefit from flow-pattern analysis. Several visualization tools have been proposed that require ultrafast ultrasound acquisitions. However, ultrafast ultrasound is not standard in clinical scanners. Meanwhile techniques that can handle low frame rates are still lacking. As a result, the clinical translation of these techniques remains limited, especially for 3D acquisitions where the volume rates are intrinsically low. Methods : To overcome these limitations, we propose a novel technique for the estimation of LV blood velocity and relative-pressure fields from dynamic contrast-enhanced ultrasound (DCE-US) at low frame rates. Different from other methods, our method is based on the time-delays between time-intensity curves measured at neighbor pixels in the DCE-US loops. Using Navier-Stokes equation, we regularize the obtained velocity fields and derive relative-pressure estimates. Blood flow patternsHighlights: Cardiac diagnostics may benefit from blood flow-pattern analysis. Current techniques for the visualization of blood flow patterns requires high acquisition rates. The employment of low acquisition rate DCE-US facilitates the clinical adaption of the method using standard ultrasound scanners. 2D and 3D velocity vector fields in the left ventricle are demonstrated and analyzed. Abstract: Background and Objective : Left ventricle (LV) dysfunction always occurs at early heart-failure stages, producing variations in the LV flow patterns. Cardiac diagnostics may therefore benefit from flow-pattern analysis. Several visualization tools have been proposed that require ultrafast ultrasound acquisitions. However, ultrafast ultrasound is not standard in clinical scanners. Meanwhile techniques that can handle low frame rates are still lacking. As a result, the clinical translation of these techniques remains limited, especially for 3D acquisitions where the volume rates are intrinsically low. Methods : To overcome these limitations, we propose a novel technique for the estimation of LV blood velocity and relative-pressure fields from dynamic contrast-enhanced ultrasound (DCE-US) at low frame rates. Different from other methods, our method is based on the time-delays between time-intensity curves measured at neighbor pixels in the DCE-US loops. Using Navier-Stokes equation, we regularize the obtained velocity fields and derive relative-pressure estimates. Blood flow patterns were characterized with regard to their vorticity, relative-pressure changes (dp/dt) in the LV outflow tract, and viscous energy loss, as these reflect the ejection efficiency. Results : We evaluated the proposed method on 18 patients (9 responders and 9 non-responders) who underwent cardiac resynchronization therapy (CRT). After CRT, the responder group evidenced a significant (p<0.05) increase in vorticity and peak dp/dt, and a non-significant decrease in viscous energy loss. No significant difference was found in the non-responder group. Relative feature variation before and after CRT evidenced a significant difference (p<0.05) between responders and non-responders for vorticity and peak dp/dt. Finally, the method feasibility is also shown with 3D DCE-US. Conclusions : Using the proposed method, adequate visualization and quantification of blood flow patterns are successfully enabled based on low-rate DCE-US of the LV, facilitating the clinical adoption of the method using standard ultrasound scanners. The clinical value of the method in the context of CRT is also shown. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 198(2021)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 198(2021)
- Issue Display:
- Volume 198, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 198
- Issue:
- 2021
- Issue Sort Value:
- 2021-0198-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01
- Subjects:
- Left ventricle -- Contrast ultrasound -- Low rate -- Blood flow patterns
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2020.105810 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14961.xml