Normothermia in Patients With Sepsis Who Present to Emergency Departments Is Associated With Low Compliance With Sepsis Bundles and Increased In-Hospital Mortality Rate*. Issue 10 (October 2020)
- Record Type:
- Journal Article
- Title:
- Normothermia in Patients With Sepsis Who Present to Emergency Departments Is Associated With Low Compliance With Sepsis Bundles and Increased In-Hospital Mortality Rate*. Issue 10 (October 2020)
- Main Title:
- Normothermia in Patients With Sepsis Who Present to Emergency Departments Is Associated With Low Compliance With Sepsis Bundles and Increased In-Hospital Mortality Rate*
- Authors:
- Park, Sunghoon
Jeon, Kyeongman
Oh, Dong Kyu
Choi, Eun Young
Seong, Gil Myeong
Heo, Jeongwon
Chang, Youjin
Kwack, Won Gun
Kang, Byung Ju
Choi, Won-Il
Kim, Kyung Chan
Park, So Young
Shin, Yoon Mi
Lee, Heung Bum
Park, So Hee
Kim, Seok Chan
Kwak, Sang Hyun
Cho, Jae Hwa
Kim, Beongki
Lim, Chae-Man - Abstract:
- Abstract : Objectives: To investigate the impact of normothermia on compliance with sepsis bundles and in-hospital mortality in patients with sepsis who present to emergency departments. Design: Retrospective multicenter observational study. Patients: Nineteen university-affiliated hospitals of the Korean Sepsis Alliance participated in this study. Data were collected regarding patients who visited emergency departments for sepsis during the 1-month period. The patients were divided into three groups based on their body temperature at the time of triage in the emergency department (i.e., hypothermia [< 36°C] vs normothermia [36–38°C] vs hyperthermia [> 38°C]). Interventions: None. Measurements and Main Results: Of 64, 021 patients who visited emergency departments, 689 with community-acquired sepsis were analyzed (182 hyperthermic, 420 normothermic, and 87 hypothermic patients). The rate of compliance with the total hour-1 bundle was lowest in the normothermia group (6.0% vs 9.3% in hyperthermia vs 13.8% in hypothermia group; p = 0.032), the rate for lactate measurement was lowest in the normothermia group (62.1% vs 73.1% vs 75.9%; p = 0.005), and the blood culture rate was significantly lower in the normothermia than in the hyperthermia group ( p < 0.001). The in-hospital mortality rates in the hyperthermia, normothermia, and hypothermia groups were 8.5%, 20.6%, and 30.8%, respectively ( p < 0.001), but there was no significant association between compliance with sepsisAbstract : Objectives: To investigate the impact of normothermia on compliance with sepsis bundles and in-hospital mortality in patients with sepsis who present to emergency departments. Design: Retrospective multicenter observational study. Patients: Nineteen university-affiliated hospitals of the Korean Sepsis Alliance participated in this study. Data were collected regarding patients who visited emergency departments for sepsis during the 1-month period. The patients were divided into three groups based on their body temperature at the time of triage in the emergency department (i.e., hypothermia [< 36°C] vs normothermia [36–38°C] vs hyperthermia [> 38°C]). Interventions: None. Measurements and Main Results: Of 64, 021 patients who visited emergency departments, 689 with community-acquired sepsis were analyzed (182 hyperthermic, 420 normothermic, and 87 hypothermic patients). The rate of compliance with the total hour-1 bundle was lowest in the normothermia group (6.0% vs 9.3% in hyperthermia vs 13.8% in hypothermia group; p = 0.032), the rate for lactate measurement was lowest in the normothermia group (62.1% vs 73.1% vs 75.9%; p = 0.005), and the blood culture rate was significantly lower in the normothermia than in the hyperthermia group ( p < 0.001). The in-hospital mortality rates in the hyperthermia, normothermia, and hypothermia groups were 8.5%, 20.6%, and 30.8%, respectively ( p < 0.001), but there was no significant association between compliance with sepsis bundles and in-hospital mortality. However, in a multivariate analysis, compared with hyperthermia, normothermia was significantly associated with an increased in-hospital mortality (odds ratio, 2.472; 95% CI, 1.005–6.080). This association remained significant even after stratifying patients by median lactate level. Conclusions: Normothermia at emergency department triage was significantly associated with an increased risk of in-hospital mortality and a lower rate of compliance with the sepsis bundle. Despite several limitations, our findings suggest a need for new strategies to improve sepsis outcomes in this group of patients. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Critical care medicine. Volume 48:Issue 10(2020)
- Journal:
- Critical care medicine
- Issue:
- Volume 48:Issue 10(2020)
- Issue Display:
- Volume 48, Issue 10 (2020)
- Year:
- 2020
- Volume:
- 48
- Issue:
- 10
- Issue Sort Value:
- 2020-0048-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10
- Subjects:
- emergency department -- mortality -- normothermia -- sepsis bundles
Critical care medicine -- Periodicals
Soins intensifs -- Périodiques
616.028 - Journal URLs:
- http://journals.lww.com/ccmjournal/Pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/CCM.0000000000004493 ↗
- Languages:
- English
- ISSNs:
- 0090-3493
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3487.451000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14956.xml