Radiological emergency dosimetry – The use of luminescent mineral fillers in polymer-based fabrics. (June 2020)
- Record Type:
- Journal Article
- Title:
- Radiological emergency dosimetry – The use of luminescent mineral fillers in polymer-based fabrics. (June 2020)
- Main Title:
- Radiological emergency dosimetry – The use of luminescent mineral fillers in polymer-based fabrics
- Authors:
- Bossin, Lily
Bailiff, Ian
Terry, Ian - Abstract:
- Abstract: Mineral fillers are widely used in the manufacture of thermoplastics and they are commonly found in the fabrics used to form bags. We show that carbonate mineral filler grains incorporated within faux leather fabrics and the coatings applied to woven nylon fibre fabrics exhibit a bright thermoluminescence TL response to ionising radiation dose, similar to that of calcite, with a broad thermoluminescence (TL) peak at 100 °C. The fabrics tested are shown to be potentially suitable as a surrogate material for emergency dosimetry, exhibiting a linear TL response to dose between 0.1 and 10 Gy, and with a detection limit varying with fabric type from 4 to 400 mGy. The region of the TL glow curve selected for dose evaluation was between ca 100–200 °C, and this is restricted by the presence of a native signal associated with the 250 °C TL peak. The rate of fading observed varied with glow curve temperature, attributed to the presence of a distribution of trapping levels; following 24 h storage at room temperature the loss recorded for the optimal glow curve temperature region selected (160–162 °C) ranged from 30 to 80 %, according to fabric and filler type. However, the fading mechanism is predominantly thermal and its rate can be substantially reduced by storing irradiated materials below room temperature. The use of filler minerals incorporated in the manufacture of plastics provides the scope to exploit a much wider range of materials for application to emergencyAbstract: Mineral fillers are widely used in the manufacture of thermoplastics and they are commonly found in the fabrics used to form bags. We show that carbonate mineral filler grains incorporated within faux leather fabrics and the coatings applied to woven nylon fibre fabrics exhibit a bright thermoluminescence TL response to ionising radiation dose, similar to that of calcite, with a broad thermoluminescence (TL) peak at 100 °C. The fabrics tested are shown to be potentially suitable as a surrogate material for emergency dosimetry, exhibiting a linear TL response to dose between 0.1 and 10 Gy, and with a detection limit varying with fabric type from 4 to 400 mGy. The region of the TL glow curve selected for dose evaluation was between ca 100–200 °C, and this is restricted by the presence of a native signal associated with the 250 °C TL peak. The rate of fading observed varied with glow curve temperature, attributed to the presence of a distribution of trapping levels; following 24 h storage at room temperature the loss recorded for the optimal glow curve temperature region selected (160–162 °C) ranged from 30 to 80 %, according to fabric and filler type. However, the fading mechanism is predominantly thermal and its rate can be substantially reduced by storing irradiated materials below room temperature. The use of filler minerals incorporated in the manufacture of plastics provides the scope to exploit a much wider range of materials for application to emergency dosimetry. Highlights: Mineral fillers widely used in the manufacture of thermoplastic exhibit a bright thermoluminescence (TL) signal. Mineral fillers are commonly found in the fabric of bags and their TL response can be used for emergency dosimetry. Their signal yields a linear dose response in the range 0.1–10 Gy with detection limits from 4 to 400 mGy. The fading is sample dependent but can be circumvented by storing the samples at low temperature (−15 °C). … (more)
- Is Part Of:
- Radiation measurements. Volume 134(2020:Mar.)
- Journal:
- Radiation measurements
- Issue:
- Volume 134(2020:Mar.)
- Issue Display:
- Volume 134 (2020)
- Year:
- 2020
- Volume:
- 134
- Issue Sort Value:
- 2020-0134-0000-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06
- Subjects:
- Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2020.106318 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14957.xml