Three dimensional validation of an instrumented handrail for stair gait. (December 2020)
- Record Type:
- Journal Article
- Title:
- Three dimensional validation of an instrumented handrail for stair gait. (December 2020)
- Main Title:
- Three dimensional validation of an instrumented handrail for stair gait
- Authors:
- Miramand, Ludovic
Richard, Vincent
McFadyen, Bradford J.
Turcot, Katia - Abstract:
- Highlights: Measuring force under an inclined handrail induces cross-talk. Few validated handrails exist, especially with load cells that are easier to set up. Inclined handrails with load cells show accurate mesures with low cross-talk. Abstract: Some studies have used load cells (LC) to measure the force applied to horizontal handrails, but no work has validated an inclined set-up that can be used to bring new insights into handrail use during staircase gait. The aim of this study was to validate the accuracy of an inclined handrail set-up instrumented with LC. A handrail set-up designed to be easily reconstructed and integrating two commercial LC is proposed. Twenty points were tested along the handrail, with four reference weights in the three orthogonal directions of the sensors (Medio-Lateral, Antero-Posterior, Vertical). For each direction, the percentage (%) of error and the cross-talk between the known and recorded forces were calculated. A linear regression of the % error was performed to evaluate measurement accuracy in relation to point of application along the handrail. The current easily replicated set-up of an inclined handrail showed accurate measures with low cross-talk. The percentage of error and cross-talk were below 3.7% and 3.7%, respectively, consistent with previous studies evaluating inclined handrail with other methods. The error and cross-talk were greater in the Medio-Lateral and Antero-Posterior directions. The error in the Antero-PosteriorHighlights: Measuring force under an inclined handrail induces cross-talk. Few validated handrails exist, especially with load cells that are easier to set up. Inclined handrails with load cells show accurate mesures with low cross-talk. Abstract: Some studies have used load cells (LC) to measure the force applied to horizontal handrails, but no work has validated an inclined set-up that can be used to bring new insights into handrail use during staircase gait. The aim of this study was to validate the accuracy of an inclined handrail set-up instrumented with LC. A handrail set-up designed to be easily reconstructed and integrating two commercial LC is proposed. Twenty points were tested along the handrail, with four reference weights in the three orthogonal directions of the sensors (Medio-Lateral, Antero-Posterior, Vertical). For each direction, the percentage (%) of error and the cross-talk between the known and recorded forces were calculated. A linear regression of the % error was performed to evaluate measurement accuracy in relation to point of application along the handrail. The current easily replicated set-up of an inclined handrail showed accurate measures with low cross-talk. The percentage of error and cross-talk were below 3.7% and 3.7%, respectively, consistent with previous studies evaluating inclined handrail with other methods. The error and cross-talk were greater in the Medio-Lateral and Antero-Posterior directions. The error in the Antero-Posterior direction was larger over the upper part of the handrail. Graphical abstract: Image, graphical abstract … (more)
- Is Part Of:
- Medical engineering & physics. Volume 86(2020)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 86(2020)
- Issue Display:
- Volume 86, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 86
- Issue:
- 2020
- Issue Sort Value:
- 2020-0086-2020-0000
- Page Start:
- 16
- Page End:
- 19
- Publication Date:
- 2020-12
- Subjects:
- Stair -- Load cell -- Reaction forces -- Handrail -- Movement analysis
AP Antero-Posterior -- LC load cells -- ML Medio-Lateral
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2020.10.005 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14923.xml