A novel micromotion measurement method to gain instructive insight into the acetabular bone-implant interface. (December 2020)
- Record Type:
- Journal Article
- Title:
- A novel micromotion measurement method to gain instructive insight into the acetabular bone-implant interface. (December 2020)
- Main Title:
- A novel micromotion measurement method to gain instructive insight into the acetabular bone-implant interface
- Authors:
- Heilemann, Martin
Wendler, Toni
Münst, Philipp
Schleifenbaum, Stefan
Scholz, Roger
Voigt, Christian - Abstract:
- Highlights: Pin-sleeve sensors transmit bone-implant micromotion from their interface out. Optical tracking of sensors by 3D image correlation. Calculation of bone-implant micromotion in six degrees of freedom. Micromotion measurement over the entire acetabular bone-implant interface. Recognition of weak spots of acetabular bone-implant compound. Abstract: In total hip arthroplasty insufficient primary stability with excessive bone-implant micromotion is a major reason for aseptic loosening at the acetabular cup implant. In the literature, several methods were proposed for in vitro micromotion measurement, but none is capable of six degrees of freedom measurement at a large number of measuring points over the entire acetabular bone-implant interface, which was the aim of the current scientific work. A pin-sleeve sensor system was developed and an appropriate installing technique was incorporated. Micromotions were transmitted from the internal interface to the accessible periphery. Motion data of the sensors were optically tracked. A calculation algorithm was conceived, discretizing superimposed rotational and translational components. The method was tested and subsequently applied to a cementless revision cup implanted into an artificial hemipelvic bone featuring a typical bone defect. Using eighteen sensors in positions across the acetabular bone-implant interface, micromotion magnitudes from 59 µm ± 2 µm to 222 µm ± 5 µm were detected. Allocation of micromotion compliedHighlights: Pin-sleeve sensors transmit bone-implant micromotion from their interface out. Optical tracking of sensors by 3D image correlation. Calculation of bone-implant micromotion in six degrees of freedom. Micromotion measurement over the entire acetabular bone-implant interface. Recognition of weak spots of acetabular bone-implant compound. Abstract: In total hip arthroplasty insufficient primary stability with excessive bone-implant micromotion is a major reason for aseptic loosening at the acetabular cup implant. In the literature, several methods were proposed for in vitro micromotion measurement, but none is capable of six degrees of freedom measurement at a large number of measuring points over the entire acetabular bone-implant interface, which was the aim of the current scientific work. A pin-sleeve sensor system was developed and an appropriate installing technique was incorporated. Micromotions were transmitted from the internal interface to the accessible periphery. Motion data of the sensors were optically tracked. A calculation algorithm was conceived, discretizing superimposed rotational and translational components. The method was tested and subsequently applied to a cementless revision cup implanted into an artificial hemipelvic bone featuring a typical bone defect. Using eighteen sensors in positions across the acetabular bone-implant interface, micromotion magnitudes from 59 µm ± 2 µm to 222 µm ± 5 µm were detected. Allocation of micromotion complied with case specific anticipations. The novel pin-sleeve sensors transmitted interface micromotion to the accessible periphery as desired. The measurement method enables instructive insights into three-dimensional bone-implant micromotion and may prospectively be used to evaluate different implant systems. … (more)
- Is Part Of:
- Medical engineering & physics. Volume 86(2020)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 86(2020)
- Issue Display:
- Volume 86, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 86
- Issue:
- 2020
- Issue Sort Value:
- 2020-0086-2020-0000
- Page Start:
- 138
- Page End:
- 145
- Publication Date:
- 2020-12
- Subjects:
- Bone-implant micromotion -- Osseointegration -- Acetabular cup -- Primary stability -- Sensor -- Total hip arthroplasty
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2020.11.002 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14923.xml