Contamination of suture material and irrigation fluid over time during athroscopic reconstruction of the anterior cruciate ligament (primary and revision) and meniscus surgery. Issue 5 (28th May 2020)
- Record Type:
- Journal Article
- Title:
- Contamination of suture material and irrigation fluid over time during athroscopic reconstruction of the anterior cruciate ligament (primary and revision) and meniscus surgery. Issue 5 (28th May 2020)
- Main Title:
- Contamination of suture material and irrigation fluid over time during athroscopic reconstruction of the anterior cruciate ligament (primary and revision) and meniscus surgery
- Authors:
- Bartek, Benjamin
Garbe, Anja
Schelberger, Tarek Guy
Gwinner, Clemens
Perka, Carsten
Jung, Tobias - Abstract:
- Aims and Objectives: During arthroscopic surgical procedures, some amount of irrigation fluid leaks from the surgical site and accumulates in the sterile reservoir. Whether these fluid collections show bacterial contamination over time in meniscus surgery and reconstruction of the anterior cruciate ligament (ACL) remains unclear. Materials and Methods: In this study, we include 200 patients. 100 patients undergoing ACL reconstruction and 100 patients undergoing meniscus surgery. We collected the samples of irrigation fluid before skin incision and every 15 minutes after the start of surgery. In addition, we evaluated the different types of suture material (Fast Fix and Outside-Inside threads in meniscus surgery and ACL reconstruction threads) for bacterial contamination. Results: At this point we evaluated samples of 152 patients (irrigation fluid of 152 patients, suture material of 100 patients). While no fluid sample showed contamination after 15 minutes, we overall detected bacterial contamination in 18, 4%. Suture material was contaminated with bacteria in 28% of cases. Conclusion: At this point, fluid surgical drape reservoirs were abacterial during the first 15 minutes but showed marked bacterial contamination over time. During surgery, irrigation fluid reservoirs should not be withdrawn by suction after skin incision. The tendency of bacterial contamination of the suture material and irrigation fluid reservoir over time has to be further explored. The continues flushAims and Objectives: During arthroscopic surgical procedures, some amount of irrigation fluid leaks from the surgical site and accumulates in the sterile reservoir. Whether these fluid collections show bacterial contamination over time in meniscus surgery and reconstruction of the anterior cruciate ligament (ACL) remains unclear. Materials and Methods: In this study, we include 200 patients. 100 patients undergoing ACL reconstruction and 100 patients undergoing meniscus surgery. We collected the samples of irrigation fluid before skin incision and every 15 minutes after the start of surgery. In addition, we evaluated the different types of suture material (Fast Fix and Outside-Inside threads in meniscus surgery and ACL reconstruction threads) for bacterial contamination. Results: At this point we evaluated samples of 152 patients (irrigation fluid of 152 patients, suture material of 100 patients). While no fluid sample showed contamination after 15 minutes, we overall detected bacterial contamination in 18, 4%. Suture material was contaminated with bacteria in 28% of cases. Conclusion: At this point, fluid surgical drape reservoirs were abacterial during the first 15 minutes but showed marked bacterial contamination over time. During surgery, irrigation fluid reservoirs should not be withdrawn by suction after skin incision. The tendency of bacterial contamination of the suture material and irrigation fluid reservoir over time has to be further explored. The continues flush and perioperative use of antibiotics might take an important impact on the low number of joint infection compared to the contamination ratio of the suture material. In addition, the effect of saturating suture material with antibiotics needs to be explored. … (more)
- Is Part Of:
- Orthopaedic journal of sports medicine. Volume 8:Issue 5(2020)Supplement 4
- Journal:
- Orthopaedic journal of sports medicine
- Issue:
- Volume 8:Issue 5(2020)Supplement 4
- Issue Display:
- Volume 8, Issue 5, Part 4 (2020)
- Year:
- 2020
- Volume:
- 8
- Issue:
- 5
- Part:
- 4
- Issue Sort Value:
- 2020-0008-0005-0004
- Page Start:
- Page End:
- Publication Date:
- 2020-05-28
- Subjects:
- Sports medicine -- Periodicals
Orthopedics -- Periodicals
Arthroscopy -- Periodicals
Arthroplasty -- Periodicals
Knee -- Surgery -- Periodicals
616.7 - Journal URLs:
- http://www.sagepublications.com/ ↗
- DOI:
- 10.1177/2325967120S00329 ↗
- Languages:
- English
- ISSNs:
- 2325-9671
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14918.xml