A novel antimicrobial coating to prevent periprosthetic joint infection. Issue 12 (1st December 2020)
- Record Type:
- Journal Article
- Title:
- A novel antimicrobial coating to prevent periprosthetic joint infection. Issue 12 (1st December 2020)
- Main Title:
- A novel antimicrobial coating to prevent periprosthetic joint infection
- Authors:
- Ramalhete, Rita
Brown, Robyn
Blunn, Gordon
Skinner, John
Coathup, Melanie
Graney, Ian
Sanghani-Kerai, Anita - Abstract:
- Abstract : Aims: Periprosthetic joint infection (PJI) is a debilitating condition with a substantial socioeconomic burden. A novel autologous blood glue (ABG) has been developed, which can be prepared during surgery and sprayed onto prostheses at the time of implantation. The ABG can potentially provide an antimicrobial coating which will be effective in preventing PJI, not only by providing a physical barrier but also by eluting a well-known antibiotic. Hence, this study aimed to assess the antimicrobial effectiveness of ABG when impregnated with gentamicin and stem cells. Methods: Gentamicin elution from the ABG matrix was analyzed and quantified in a time-dependent manner. The combined efficiency of gentamicin and ABG as an anti-biofilm coating was investigated on titanium disks. Results: ABG-gentamicin was bactericidal from 10 μg/ml and could release bactericidal concentrations over seven days, preventing biofilm formation. A concentration of 75 μg/ml of gentamicin in ABG showed the highest bactericidal effect up to day 7. On titanium disks, a significant bacterial reduction on ABG-gentamicin coated disks was observed when compared to both uncoated (mean 2-log reduction) and ABG-coated (mean 3-log reduction) disks, at days 3 and 7. ABG alone exhibited no antimicrobial or anti-biofilm properties. However, a concentration of 75 μg/ml gentamicin in ABG sustains release over seven days and significantly reduced biofilm formation. Its use as an implant coating in patientsAbstract : Aims: Periprosthetic joint infection (PJI) is a debilitating condition with a substantial socioeconomic burden. A novel autologous blood glue (ABG) has been developed, which can be prepared during surgery and sprayed onto prostheses at the time of implantation. The ABG can potentially provide an antimicrobial coating which will be effective in preventing PJI, not only by providing a physical barrier but also by eluting a well-known antibiotic. Hence, this study aimed to assess the antimicrobial effectiveness of ABG when impregnated with gentamicin and stem cells. Methods: Gentamicin elution from the ABG matrix was analyzed and quantified in a time-dependent manner. The combined efficiency of gentamicin and ABG as an anti-biofilm coating was investigated on titanium disks. Results: ABG-gentamicin was bactericidal from 10 μg/ml and could release bactericidal concentrations over seven days, preventing biofilm formation. A concentration of 75 μg/ml of gentamicin in ABG showed the highest bactericidal effect up to day 7. On titanium disks, a significant bacterial reduction on ABG-gentamicin coated disks was observed when compared to both uncoated (mean 2-log reduction) and ABG-coated (mean 3-log reduction) disks, at days 3 and 7. ABG alone exhibited no antimicrobial or anti-biofilm properties. However, a concentration of 75 μg/ml gentamicin in ABG sustains release over seven days and significantly reduced biofilm formation. Its use as an implant coating in patients with a high risk of infection may prevent bacterial adhesion perioperatively and in the early postoperative period. Conclusion: ABG's use as a carrier for stem cells was effective, as it supported cell growth. It has the potential to co-deliver compatible cells, drugs, and growth factors. However, ABG-gentamicin's potential needs to be further justified using in vivo studies. Cite this article: Bone Joint Res 2020;9(12):848–856. … (more)
- Is Part Of:
- Bone & joint research. Volume 9:Issue 12(2020)
- Journal:
- Bone & joint research
- Issue:
- Volume 9:Issue 12(2020)
- Issue Display:
- Volume 9, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 9
- Issue:
- 12
- Issue Sort Value:
- 2020-0009-0012-0000
- Page Start:
- 848
- Page End:
- 856
- Publication Date:
- 2020-12-01
- Subjects:
- Periprosthetic joint infection -- Stem cell -- Implant
Musculoskeletal system -- Periodicals
573.705 - Journal URLs:
- http://www.bjr.boneandjoint.org.uk/ ↗
- DOI:
- 10.1302/2046-3758.912.BJR-2020-0157.R1 ↗
- Languages:
- English
- ISSNs:
- 2046-3758
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital store
- Ingest File:
- 14908.xml