Acoustic emission and finite element study on the influence of cusp angles on zirconia dental crowns. Issue 12 (December 2020)
- Record Type:
- Journal Article
- Title:
- Acoustic emission and finite element study on the influence of cusp angles on zirconia dental crowns. Issue 12 (December 2020)
- Main Title:
- Acoustic emission and finite element study on the influence of cusp angles on zirconia dental crowns
- Authors:
- Ellakwa, Ayman
Raju, Raju
Sheng, Cai
Rajan, Ginu
Prusty, B. Gangadhara - Abstract:
- Highlights: Cusp angle of the dental crown is directly proportional to the load-carrying capacity. Failure always initiated at the centre of the midline of the occlusal surface. AE activity is significantly pronounced for low cusp angles. Abstract: Objective: The effect of cusp angle on the load-carrying capacity and failure behaviour of BionZ Diamond zirconia crowns is carried out using experimental and numerical investigations. Methods: The experimental program using monolithic crowns were divided into three groups (n = 14) for three cusp angles, 60, 80 and 120 degrees and were tested to failure under the static load. A 2-channel acoustic emission (AE) system was used to monitor the failure process while the piezo sensors were attached to the rigid stainless-steel jig for recoding the AE events. Load-displacement and AE response were simultaneously monitored until failure of specimens. Parametric AE analysis was conducted for the factors such as amplitude, energy released, signal duration and cumulative counts, for each AE signal. Fast Fourier transform (FFT) was conducted to assess the frequency at failure. Linear finite element analysis (FEA) was carried out using commercial software Ansys Workbench 19.1 to present the stress distribution and failure modes. Post-failure surface morphology study was carried out using scanning electron microscopy (SEM) and statistical analysis was performed using Weibull analysis. Results: All the samples in three different groups haveHighlights: Cusp angle of the dental crown is directly proportional to the load-carrying capacity. Failure always initiated at the centre of the midline of the occlusal surface. AE activity is significantly pronounced for low cusp angles. Abstract: Objective: The effect of cusp angle on the load-carrying capacity and failure behaviour of BionZ Diamond zirconia crowns is carried out using experimental and numerical investigations. Methods: The experimental program using monolithic crowns were divided into three groups (n = 14) for three cusp angles, 60, 80 and 120 degrees and were tested to failure under the static load. A 2-channel acoustic emission (AE) system was used to monitor the failure process while the piezo sensors were attached to the rigid stainless-steel jig for recoding the AE events. Load-displacement and AE response were simultaneously monitored until failure of specimens. Parametric AE analysis was conducted for the factors such as amplitude, energy released, signal duration and cumulative counts, for each AE signal. Fast Fourier transform (FFT) was conducted to assess the frequency at failure. Linear finite element analysis (FEA) was carried out using commercial software Ansys Workbench 19.1 to present the stress distribution and failure modes. Post-failure surface morphology study was carried out using scanning electron microscopy (SEM) and statistical analysis was performed using Weibull analysis. Results: All the samples in three different groups have failed at the mid-line, splitting the zirconia crowns into two equal pieces. The load to failure was directly proportional to the cusp angle in crowns; 120° group had the highest load-carrying capacity of 2.93 ± 0.26 kN while 60 and 80° groups had a failure load of 2.46 ± 0.53 and 2.52 ± 0.16 kN, respectively. Parametric AE analysis revealed that the failure was instantaneous and 60-degree samples had higher AE signature. FE analysis showed the crack initiation at the occlusal surface of the crown which is in agreement with the SEM images. A close agreement of results for the load and stress distribution from FEA complemented with the experimental study. Significance: Optimisation of cusp-angle could help clinicians to accurately design the monolithic zirconia crown focussing on maximum load-carrying capacity, increasing the restoration life. … (more)
- Is Part Of:
- Dental materials. Volume 36:Issue 12(2020)
- Journal:
- Dental materials
- Issue:
- Volume 36:Issue 12(2020)
- Issue Display:
- Volume 36, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 36
- Issue:
- 12
- Issue Sort Value:
- 2020-0036-0012-0000
- Page Start:
- 1524
- Page End:
- 1535
- Publication Date:
- 2020-12
- Subjects:
- Acoustic emission -- Dental crown -- Zirconia -- Cusp angle -- Stress concentration -- Crown failure
Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2020.09.007 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14883.xml