On the impact of geomagnetically induced currents in driving series capacitor compensated power systems to ferroresonance. (February 2021)
- Record Type:
- Journal Article
- Title:
- On the impact of geomagnetically induced currents in driving series capacitor compensated power systems to ferroresonance. (February 2021)
- Main Title:
- On the impact of geomagnetically induced currents in driving series capacitor compensated power systems to ferroresonance
- Authors:
- Behdani, Behzad
Allahbakhshi, Mehdi
Tajdinian, Mohsen - Abstract:
- Highlights: Applying analytical analysis to assess the occurrence of ferroresonance due to GIC. Experimental and numerical validations of the effect of GIC creating ferroresonance. Investigating compensation level, system loading, and grounding on GIC caused ferroresonance. Abstract: Solar storms cause disturbances in the Earth's magnetic field, which results in quasi-DC geomagnetically induced currents (GICs) flow in the grounded sections of the system. The flow of GICs in the power system may drive the power transformers to the saturation region. Moreover, HV transmission lines are often compensated by series capacitor units for enhancing the capability of power transmission lines. The proximity of power transformers and series capacitor compensation units during GICs may enhance the chance of the ferroresonance phenomenon in power transformers. The occurrence of ferroresonance produces extensively high voltages/currents in system apparatus, including transformers which can consequently result in severe damages. This paper puts forward the analysis of the power transformer ferroresonance phenomenon due to GICs in series capacitor compensated networks. This issue has been addressed through mathematical analysis and verified by an experimental test setup, in order to demonstrate the effect of GIC on ferroresonance. Through the employment of an example test system in EMTP-RV environment, impacts of different involving parameters such as system loading, compensation level, andHighlights: Applying analytical analysis to assess the occurrence of ferroresonance due to GIC. Experimental and numerical validations of the effect of GIC creating ferroresonance. Investigating compensation level, system loading, and grounding on GIC caused ferroresonance. Abstract: Solar storms cause disturbances in the Earth's magnetic field, which results in quasi-DC geomagnetically induced currents (GICs) flow in the grounded sections of the system. The flow of GICs in the power system may drive the power transformers to the saturation region. Moreover, HV transmission lines are often compensated by series capacitor units for enhancing the capability of power transmission lines. The proximity of power transformers and series capacitor compensation units during GICs may enhance the chance of the ferroresonance phenomenon in power transformers. The occurrence of ferroresonance produces extensively high voltages/currents in system apparatus, including transformers which can consequently result in severe damages. This paper puts forward the analysis of the power transformer ferroresonance phenomenon due to GICs in series capacitor compensated networks. This issue has been addressed through mathematical analysis and verified by an experimental test setup, in order to demonstrate the effect of GIC on ferroresonance. Through the employment of an example test system in EMTP-RV environment, impacts of different involving parameters such as system loading, compensation level, and substations' grounding resistances are evaluated on the occurrence of ferroresonance due to GICs. The results indicate that for series capacitor compensated power grids, GICs can profoundly enhance the vulnerability of power transformers to the occurrence of ferroresonance phenomena. … (more)
- Is Part Of:
- International journal of electrical power & energy systems. Volume 125(2021)
- Journal:
- International journal of electrical power & energy systems
- Issue:
- Volume 125(2021)
- Issue Display:
- Volume 125, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 125
- Issue:
- 2021
- Issue Sort Value:
- 2021-0125-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02
- Subjects:
- Geomagnetically induced current -- Ferroresonance -- Series capacitor compensated power grids
Electrical engineering -- Periodicals
Electric power systems -- Periodicals
Électrotechnique -- Périodiques
Réseaux électriques (Énergie) -- Périodiques
Electric power systems
Electrical engineering
Periodicals
621.3 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01420615 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijepes.2020.106424 ↗
- Languages:
- English
- ISSNs:
- 0142-0615
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.220000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14885.xml