Effect of protective glasses on radiation dose to eye lenses during whole breast irradiation. Issue 11 (30th October 2020)
- Record Type:
- Journal Article
- Title:
- Effect of protective glasses on radiation dose to eye lenses during whole breast irradiation. Issue 11 (30th October 2020)
- Main Title:
- Effect of protective glasses on radiation dose to eye lenses during whole breast irradiation
- Authors:
- Nakamura, Tokiko
Suzuki, Shoichi
Kato, Kyoichi
Pongnapang, Napapong
Hayashi, Naoki
Kurokawa, Chie
Kobayashi, Ikuo
Negishi, Toru
Matsunami, Tamaki - Abstract:
- Abstract: Objectives: The efficacy of radiotherapy for breast cancer has greatly improved owing to better irradiation methods. Radiotherapy aims to deliver therapeutic doses to predetermined target volumes while sparing surrounding healthy tissues. However, there are few reports on radiation exposure to eye lenses, and the recommended exposure limits to ocular lens have been substantially reduced in recent years. This study aimed to investigate the amount of radiation exposure to eye lenses using optically stimulated luminescence dosimeters (OSLDs) and determine whether wearing special protective devices to protect the eyes, as an organ at risk, during whole breast irradiation, is necessary. Methods: This experiment used OSLDs on water‐equivalent phantom to measure the change in scattered radiation dose due to the difference of irradiation field while using 4‐ and 6‐MV photons of TrueBeam linear accelerator. Using a total treatment dose of 50 Gy, a target was positioned to approximate the breast, and a plan was formulated to deliver 2 Gy per treatment by tangential irradiation. The mean (SD) irradiation dose at the lens position outside the irradiation field was reported. Results: The scattered radiation dose outside the irradiation field was more affected by the irradiation field size than by the radiation energy. The out‐of‐field irradiation dose with a larger field of view was higher than that with a smaller field of view. The use of 0.07‐ and 0.83‐mm‐thick lead shieldAbstract: Objectives: The efficacy of radiotherapy for breast cancer has greatly improved owing to better irradiation methods. Radiotherapy aims to deliver therapeutic doses to predetermined target volumes while sparing surrounding healthy tissues. However, there are few reports on radiation exposure to eye lenses, and the recommended exposure limits to ocular lens have been substantially reduced in recent years. This study aimed to investigate the amount of radiation exposure to eye lenses using optically stimulated luminescence dosimeters (OSLDs) and determine whether wearing special protective devices to protect the eyes, as an organ at risk, during whole breast irradiation, is necessary. Methods: This experiment used OSLDs on water‐equivalent phantom to measure the change in scattered radiation dose due to the difference of irradiation field while using 4‐ and 6‐MV photons of TrueBeam linear accelerator. Using a total treatment dose of 50 Gy, a target was positioned to approximate the breast, and a plan was formulated to deliver 2 Gy per treatment by tangential irradiation. The mean (SD) irradiation dose at the lens position outside the irradiation field was reported. Results: The scattered radiation dose outside the irradiation field was more affected by the irradiation field size than by the radiation energy. The out‐of‐field irradiation dose with a larger field of view was higher than that with a smaller field of view. The use of 0.07‐ and 0.83‐mm‐thick lead shield protective glasses reduced the radiation dose by 56.1% ( P < .001) and 55.6% ( P < .001), respectively. Conclusions: In this experimental model, the amount of radiation the eye was exposed to during whole breast irradiation was determined by the distance of the eye from the radiation field edge and by wearing protective glasses. In clinical practice, the protection offered by eyeglasses may reduce the risk of long‐term side effects and allow the use of higher intensive radiotherapy. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 21:Issue 11(2020)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 21:Issue 11(2020)
- Issue Display:
- Volume 21, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 11
- Issue Sort Value:
- 2020-0021-0011-0000
- Page Start:
- 272
- Page End:
- 277
- Publication Date:
- 2020-10-30
- Subjects:
- Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13073 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14897.xml