Feasibility and outcomes of fetoscopic endoluminal tracheal occlusion for severe congenital diaphragmatic hernia: A Japanese experience. Issue 12 (28th September 2020)
- Record Type:
- Journal Article
- Title:
- Feasibility and outcomes of fetoscopic endoluminal tracheal occlusion for severe congenital diaphragmatic hernia: A Japanese experience. Issue 12 (28th September 2020)
- Main Title:
- Feasibility and outcomes of fetoscopic endoluminal tracheal occlusion for severe congenital diaphragmatic hernia: A Japanese experience
- Authors:
- Wada, Seiji
Ozawa, Katsusuke
Sugibayashi, Rika
Suyama, Fumio
Amari, Shoichiro
Ito, Yushi
Kanamori, Yutaka
Okuyama, Hiroomi
Usui, Noriaki
Sasahara, Jun
Kotani, Tomomi
Hayakawa, Masahiro
Kato, Kiyoko
Taguchi, Tomoaki
Endo, Masayuki
Sago, Haruhiko - Abstract:
- Abstract: Aim: To present the feasibility, safety and outcomes of fetoscopic endoluminal tracheal occlusion (FETO) for the treatment of severe congenital diaphragmatic hernia (CDH). Methods: This was a single‐arm clinical trial of FETO for isolated left‐sided CDH with liver herniation and Kitano Grade 3 stomach position (>50% stomach herniation into the right chest). FETO was performed at 27–29 weeks of gestation for cases with observed/expected lung to head ratio (o/e LHR) <25% and at 30–31 weeks for cases with o/e LHR ≥25%. Results: Eleven cases were enrolled between March 2014 and March 2016, and balloon insertion was successful in all cases. The median o/e LHR at entry was 27% (range, 20–33%). The median gestational age at FETO was 30.9 (range, 27.1–31.7) weeks. There were no severe maternal adverse events. One fetus died unexpectedly at 33 weeks of gestation due to cord strangulation by the detached amniotic membrane. There were 3 cases (27%) of preterm premature rupture of membranes. In all 10 cases, balloon removal at 34–35 weeks of gestation was successful. The median gestational age at delivery was 36.5 (range, 34.2–38.3) weeks. The median duration of occlusion and the median interval between balloon insertion and delivery were 26 days (range: 17–49 days) and 43 days (range, 21–66 days), respectively. Both the survival rate at 90 days of age and the rate of survival to discharge were 45% (5/11). Conclusion: The FETO is feasible without maternal morbidity in JapanAbstract: Aim: To present the feasibility, safety and outcomes of fetoscopic endoluminal tracheal occlusion (FETO) for the treatment of severe congenital diaphragmatic hernia (CDH). Methods: This was a single‐arm clinical trial of FETO for isolated left‐sided CDH with liver herniation and Kitano Grade 3 stomach position (>50% stomach herniation into the right chest). FETO was performed at 27–29 weeks of gestation for cases with observed/expected lung to head ratio (o/e LHR) <25% and at 30–31 weeks for cases with o/e LHR ≥25%. Results: Eleven cases were enrolled between March 2014 and March 2016, and balloon insertion was successful in all cases. The median o/e LHR at entry was 27% (range, 20–33%). The median gestational age at FETO was 30.9 (range, 27.1–31.7) weeks. There were no severe maternal adverse events. One fetus died unexpectedly at 33 weeks of gestation due to cord strangulation by the detached amniotic membrane. There were 3 cases (27%) of preterm premature rupture of membranes. In all 10 cases, balloon removal at 34–35 weeks of gestation was successful. The median gestational age at delivery was 36.5 (range, 34.2–38.3) weeks. The median duration of occlusion and the median interval between balloon insertion and delivery were 26 days (range: 17–49 days) and 43 days (range, 21–66 days), respectively. Both the survival rate at 90 days of age and the rate of survival to discharge were 45% (5/11). Conclusion: The FETO is feasible without maternal morbidity in Japan and could be offered to women whose fetuses show severe isolated left‐sided CDH to accelerate fetal lung growth. … (more)
- Is Part Of:
- Journal of obstetrics and gynaecology research. Volume 46:Issue 12(2020)
- Journal:
- Journal of obstetrics and gynaecology research
- Issue:
- Volume 46:Issue 12(2020)
- Issue Display:
- Volume 46, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 46
- Issue:
- 12
- Issue Sort Value:
- 2020-0046-0012-0000
- Page Start:
- 2598
- Page End:
- 2604
- Publication Date:
- 2020-09-28
- Subjects:
- adverse events -- congenital diaphragmatic hernia -- fetal mortality -- fetal therapy -- fetoscopy
Gynecology -- Periodicals
Obstetrics -- Periodicals
618.1005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1447-0756 ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jog ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jog.14504 ↗
- Languages:
- English
- ISSNs:
- 1341-8076
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5026.055000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14887.xml