Automated treatment planning as a dose escalation strategy for stereotactic radiation therapy in pancreatic cancer. Issue 11 (16th October 2020)
- Record Type:
- Journal Article
- Title:
- Automated treatment planning as a dose escalation strategy for stereotactic radiation therapy in pancreatic cancer. Issue 11 (16th October 2020)
- Main Title:
- Automated treatment planning as a dose escalation strategy for stereotactic radiation therapy in pancreatic cancer
- Authors:
- Cilla, Savino
Ianiro, Anna
Romano, Carmela
Deodato, Francesco
Macchia, Gabriella
Viola, Pietro
Buwenge, Milly
Cammelli, Silvia
Pierro, Antonio
Valentini, Vincenzo
Morganti, Alessio G. - Abstract:
- Abstract: Purpose: To assess the feasibility of automated stereotactic volumetric modulated arc therapy (SBRT‐VMAT) planning using a simultaneous integrated boost (SIB) approach as a dose escalation strategy for SBRT in pancreatic cancer. Methods: Twelve patients with pancreatic cancer were retrospectively replanned. Dose prescription was 30 Gy to the planning target volume (PTV) and was escalated up to 50 Gy to the boost target volume (BTV) using a SIB technique in 5 fractions. All plans were generated by Pinnacle 3 Autoplanning using 6MV dual‐arc VMAT technique for flattened (FF) and flattening filter‐free beams (FFF). An overlap volume (OLV) between the PRV duodenum and the PTV was defined to correlate with the ability to boost the BTV. Dosimetric metrics for BTV and PTV coverage, maximal doses for serial OARs, integral dose, conformation numbers, and dose contrast indexes were used to analyze the dosimetric results. Dose accuracy was validated using the PTW Octavius‐4D phantom together with the 1500 2D‐array. Differences between FF and FFF plans were quantified using the Wilcoxon matched‐pair signed rank. Results: Full prescription doses to the 95% of PTV and BTV can be delivered to patients with no OLV. BTV mean dose was >90% of the prescribed doses for all patients at all dose levels. Compared to FF plans, FFF plans showed significant reduced integral doses, larger number of MUs, and reduced beam‐on‐times up to 51% for the highest dose level. Despite plan complexity,Abstract: Purpose: To assess the feasibility of automated stereotactic volumetric modulated arc therapy (SBRT‐VMAT) planning using a simultaneous integrated boost (SIB) approach as a dose escalation strategy for SBRT in pancreatic cancer. Methods: Twelve patients with pancreatic cancer were retrospectively replanned. Dose prescription was 30 Gy to the planning target volume (PTV) and was escalated up to 50 Gy to the boost target volume (BTV) using a SIB technique in 5 fractions. All plans were generated by Pinnacle 3 Autoplanning using 6MV dual‐arc VMAT technique for flattened (FF) and flattening filter‐free beams (FFF). An overlap volume (OLV) between the PRV duodenum and the PTV was defined to correlate with the ability to boost the BTV. Dosimetric metrics for BTV and PTV coverage, maximal doses for serial OARs, integral dose, conformation numbers, and dose contrast indexes were used to analyze the dosimetric results. Dose accuracy was validated using the PTW Octavius‐4D phantom together with the 1500 2D‐array. Differences between FF and FFF plans were quantified using the Wilcoxon matched‐pair signed rank. Results: Full prescription doses to the 95% of PTV and BTV can be delivered to patients with no OLV. BTV mean dose was >90% of the prescribed doses for all patients at all dose levels. Compared to FF plans, FFF plans showed significant reduced integral doses, larger number of MUs, and reduced beam‐on‐times up to 51% for the highest dose level. Despite plan complexity, pre‐treatment verification reported a gamma pass‐rate greater than the acceptance threshold of 95% for all FF and FFF plans for 3%‐2 mm criteria. Conclusions: The SIB‐SBRT strategy with Autoplanning was dosimetrically feasible. Ablative doses up to 50 Gy in 5 fractions can be delivered to the BTV for almost all patients respecting all the normal tissue constraints. A prospective clinical trial based on SBRT strategy using SIB‐VMAT technique with FFF beams seems to be justified. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 21:Issue 11(2020)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 21:Issue 11(2020)
- Issue Display:
- Volume 21, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 11
- Issue Sort Value:
- 2020-0021-0011-0000
- Page Start:
- 48
- Page End:
- 57
- Publication Date:
- 2020-10-16
- Subjects:
- autoplanning -- SBRT -- SIB -- pancreas
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13025 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14897.xml