Comparison of non‐contrast‐enhanced dental magnetic resonance imaging and cone‐beam computed tomography in assessing the horizontal and vertical components of furcation defects in maxillary molars: An in vivo feasibility study. (20th October 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of non‐contrast‐enhanced dental magnetic resonance imaging and cone‐beam computed tomography in assessing the horizontal and vertical components of furcation defects in maxillary molars: An in vivo feasibility study. (20th October 2020)
- Main Title:
- Comparison of non‐contrast‐enhanced dental magnetic resonance imaging and cone‐beam computed tomography in assessing the horizontal and vertical components of furcation defects in maxillary molars: An in vivo feasibility study
- Authors:
- Juerchott, Alexander
Sohani, Meysam
Schwindling, Franz Sebastian
Jende, Johann M. E.
Kurz, Felix T.
Rammelsberg, Peter
Heiland, Sabine
Bendszus, Martin
Hilgenfeld, Tim - Abstract:
- Abstract: Aim: To compare non‐contrast‐enhanced dental magnetic resonance imaging (NCE‐dMRI) and cone‐beam computed tomography (CBCT) in assessing horizontal and vertical furcation defects in maxillary molars in vivo. Materials and methods: (NCE‐dMRI) and CBCT were performed in 23 patients with severe periodontitis. Sixty‐five first/second maxillary molars (195 furcation entrances) were analysed by two independent observers on both modalities to assess the horizontal and vertical components of furcation defects. Reliability of defect classification was evaluated using weighted kappa ( κ ) statistics. Agreement between NCE‐dMRI and CBCT was determined by the Bland–Altman analysis. Sensitivity and specificity of NCE‐dMRI were calculated using CBCT as the reference. Results: Inter‐radicular bone loss was observed in 94 furcation entrances. Intra‐ and inter‐rater κ ‐values were ≥0.9 for both NCE‐dMRI and CBCT. The Bland–Altman analysis showed mean differences (95% limits of agreement) of 0.12 mm (−0.67 to 0.90) for horizontal and 0.12 mm (−1.27 to 1.50) for vertical measurements. For the detection of furcation defects, sensitivity/specificity of NCE‐dMRI was 98%/100% for horizontal and 99%/99% for vertical components. For defect classification, sensitivity values of NCE‐dMRI were 88%/89%/100% (horizontal degree I/II/III) and 95%/91%/80% (vertical subclass A/B/C), respectively. Conclusions: Non‐contrast‐enhanced dental magnetic resonance imaging demonstrated high reliability andAbstract: Aim: To compare non‐contrast‐enhanced dental magnetic resonance imaging (NCE‐dMRI) and cone‐beam computed tomography (CBCT) in assessing horizontal and vertical furcation defects in maxillary molars in vivo. Materials and methods: (NCE‐dMRI) and CBCT were performed in 23 patients with severe periodontitis. Sixty‐five first/second maxillary molars (195 furcation entrances) were analysed by two independent observers on both modalities to assess the horizontal and vertical components of furcation defects. Reliability of defect classification was evaluated using weighted kappa ( κ ) statistics. Agreement between NCE‐dMRI and CBCT was determined by the Bland–Altman analysis. Sensitivity and specificity of NCE‐dMRI were calculated using CBCT as the reference. Results: Inter‐radicular bone loss was observed in 94 furcation entrances. Intra‐ and inter‐rater κ ‐values were ≥0.9 for both NCE‐dMRI and CBCT. The Bland–Altman analysis showed mean differences (95% limits of agreement) of 0.12 mm (−0.67 to 0.90) for horizontal and 0.12 mm (−1.27 to 1.50) for vertical measurements. For the detection of furcation defects, sensitivity/specificity of NCE‐dMRI was 98%/100% for horizontal and 99%/99% for vertical components. For defect classification, sensitivity values of NCE‐dMRI were 88%/89%/100% (horizontal degree I/II/III) and 95%/91%/80% (vertical subclass A/B/C), respectively. Conclusions: Non‐contrast‐enhanced dental magnetic resonance imaging demonstrated high reliability and high agreement with CBCT for the assessment of furcation defects in maxillary molars. … (more)
- Is Part Of:
- Journal of clinical periodontology. Volume 47:Number 12(2020)
- Journal:
- Journal of clinical periodontology
- Issue:
- Volume 47:Number 12(2020)
- Issue Display:
- Volume 47, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 12
- Issue Sort Value:
- 2020-0047-0012-0000
- Page Start:
- 1485
- Page End:
- 1495
- Publication Date:
- 2020-10-20
- Subjects:
- 3D imaging -- cone‐beam computed tomography -- furcation defects -- magnetic resonance imaging -- periodontitis
Periodontics -- Periodicals
617.6 - Journal URLs:
- http://www.blackwell-synergy.com/loi/cpe ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-051X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jcpe.13374 ↗
- Languages:
- English
- ISSNs:
- 0303-6979
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.672000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14883.xml