Impact of setup errors on multi‐isocenter volumetric modulated arc therapy for craniospinal irradiation. Issue 11 (18th October 2020)
- Record Type:
- Journal Article
- Title:
- Impact of setup errors on multi‐isocenter volumetric modulated arc therapy for craniospinal irradiation. Issue 11 (18th October 2020)
- Main Title:
- Impact of setup errors on multi‐isocenter volumetric modulated arc therapy for craniospinal irradiation
- Authors:
- Zhou, Yongqiang
Ai, Yao
Han, Ce
Zheng, Xiaomin
Yi, Jinling
Xie, Congying
Jin, Xiance - Abstract:
- Abstract: Multi‐isocenter volumetric modulated arc therapy (VMAT) is recommended for craniospinal irradiation (CSI) to smooth the dose distribution in the junction regions relying solely on inverse optimization. However, few studies have measured the dosimetric impact of setup errors on this multi‐isocenter VMAT in the junction areas. The purpose of this study is to evaluate the impact of positional errors during VMAT CSI with two‐dimension (2D) and three‐dimension (3D) dosimetric measurements. A total of 20 patients treated by three‐isocenter VMAT CSI were retrospectively reviewed and analyzed. A 3D diode array ArcCHECK and radiochromic film EBT3 were applied to measure the percentage gamma passing rates (%GPs) and dose distributions in the junction areas between the cranial/upper‐spinal and the upper/lower‐spinal fields with intentionally introduced setup errors of ± 1 mm, ±2 mm, ±3 mm, ±5 mm, and ± 8 mm, respectively. The length and volume of planning target volume (PTV) for these CSI patients ranged from 50.14 to 80.8 cm, and 1572.3 to 2114.5 cm 3, respectively. The %GPs for ±3 mm, ±5 mm, and ±8 mm positional errors were around 95%, 90%, and 85%, respectively, in the junction areas. The dosimetric verification results with EBT3 films indicated that cold and hot areas were observed with the increase of introduced setup errors. In conclusion, the dosimetric verification with intentionally introduced setup errors demonstrated that positional errors within 3 mm have a littleAbstract: Multi‐isocenter volumetric modulated arc therapy (VMAT) is recommended for craniospinal irradiation (CSI) to smooth the dose distribution in the junction regions relying solely on inverse optimization. However, few studies have measured the dosimetric impact of setup errors on this multi‐isocenter VMAT in the junction areas. The purpose of this study is to evaluate the impact of positional errors during VMAT CSI with two‐dimension (2D) and three‐dimension (3D) dosimetric measurements. A total of 20 patients treated by three‐isocenter VMAT CSI were retrospectively reviewed and analyzed. A 3D diode array ArcCHECK and radiochromic film EBT3 were applied to measure the percentage gamma passing rates (%GPs) and dose distributions in the junction areas between the cranial/upper‐spinal and the upper/lower‐spinal fields with intentionally introduced setup errors of ± 1 mm, ±2 mm, ±3 mm, ±5 mm, and ± 8 mm, respectively. The length and volume of planning target volume (PTV) for these CSI patients ranged from 50.14 to 80.8 cm, and 1572.3 to 2114.5 cm 3, respectively. The %GPs for ±3 mm, ±5 mm, and ±8 mm positional errors were around 95%, 90%, and 85%, respectively, in the junction areas. The dosimetric verification results with EBT3 films indicated that cold and hot areas were observed with the increase of introduced setup errors. In conclusion, the dosimetric verification with intentionally introduced setup errors demonstrated that positional errors within 3 mm have a little impact for VMAT CSI, although setup errors should be minimized. Relying on the inverse optimization of VMAT to smooth the dose distribution in the junction areas is feasible for CSI. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 21:Issue 11(2020)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 21:Issue 11(2020)
- Issue Display:
- Volume 21, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 21
- Issue:
- 11
- Issue Sort Value:
- 2020-0021-0011-0000
- Page Start:
- 115
- Page End:
- 123
- Publication Date:
- 2020-10-18
- Subjects:
- craniospinal irradiation -- dosimetric measurement -- setup errors -- volumetric modulated arc therapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13044 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14856.xml