Comparison between lung perfusion scan and single-photon emission computed tomography/computed tomography for predicting postoperative lung function after pulmonary resection in patients with borderline lung function. (3rd September 2020)
- Record Type:
- Journal Article
- Title:
- Comparison between lung perfusion scan and single-photon emission computed tomography/computed tomography for predicting postoperative lung function after pulmonary resection in patients with borderline lung function. (3rd September 2020)
- Main Title:
- Comparison between lung perfusion scan and single-photon emission computed tomography/computed tomography for predicting postoperative lung function after pulmonary resection in patients with borderline lung function
- Authors:
- Na, Kwon Joong
Park, Samina
Lee, Hyun Joo
Park, In Kyu
Kang, Chang Hyun
Kim, Young Tae - Abstract:
- Abstract : Physiological evaluation before pulmonary resection, especially prediction of pulmonary reserve, is important for assessing surgical risk and for evaluating whether a patient can tolerate surgery [1–4]. Abstract: OBJECTIVES: We compared the usefulness of single-photon emission computed tomography/computed tomography (SPECT/CT) and lung perfusion scintigraphy (LPS) for predicting postoperative lung function by comparing patients with borderline lung function. METHODS: A total of 274 patients who underwent simultaneous LPS and SPECT/CT and had a forced expiratory volume in 1 s (FEV1 ) or diffusing capacity for carbon monoxide (DLCO ) under 80% were included. The % uptake by LPS was calculated by the posterior-oblique method. The concordance and difference of the % uptake, predicted postoperative (ppo) FEV1 and ppoDLCO as determined by 2 methods were evaluated. The association between ppo values and actual postoperative FEV1 and DLCO was examined. Subgroup analysis was conducted in redo-operation cases. RESULTS: The % uptake of each lobe, except the right middle lobe, showed fair concordance (concordance correlation coefficients for right upper, middle, lower, left upper and lower lobe = 0.61, 0.37, 0.71, 0.66 and 0.69, respectively). ppoFEV1 and ppoDLCO also revealed high concordance between both methods (concordance correlation coefficient = 0.93 for ppoFEV1 and concordance correlation coefficient = 0.92 for ppoDLCO ) without a significant difference ( P = 0.42Abstract : Physiological evaluation before pulmonary resection, especially prediction of pulmonary reserve, is important for assessing surgical risk and for evaluating whether a patient can tolerate surgery [1–4]. Abstract: OBJECTIVES: We compared the usefulness of single-photon emission computed tomography/computed tomography (SPECT/CT) and lung perfusion scintigraphy (LPS) for predicting postoperative lung function by comparing patients with borderline lung function. METHODS: A total of 274 patients who underwent simultaneous LPS and SPECT/CT and had a forced expiratory volume in 1 s (FEV1 ) or diffusing capacity for carbon monoxide (DLCO ) under 80% were included. The % uptake by LPS was calculated by the posterior-oblique method. The concordance and difference of the % uptake, predicted postoperative (ppo) FEV1 and ppoDLCO as determined by 2 methods were evaluated. The association between ppo values and actual postoperative FEV1 and DLCO was examined. Subgroup analysis was conducted in redo-operation cases. RESULTS: The % uptake of each lobe, except the right middle lobe, showed fair concordance (concordance correlation coefficients for right upper, middle, lower, left upper and lower lobe = 0.61, 0.37, 0.71, 0.66 and 0.69, respectively). ppoFEV1 and ppoDLCO also revealed high concordance between both methods (concordance correlation coefficient = 0.93 for ppoFEV1 and concordance correlation coefficient = 0.92 for ppoDLCO ) without a significant difference ( P = 0.42 for ppoFEV1 ; P = 0.31 for ppoDLCO ). Both ppoFEV1 and ppoDLCO showed a significantly high correlation with the actual FEV1 ( r = 0.77, P < 0.01 for LPS, r = 0.77, P < 0.01 for SPECT/CT) and DLCO ( r = 0.62, P < 0.01 for LPS, r = 0.62, P < 0.01 for SPECT/CT). High concordance of % uptake, ppoFEV1 and ppoDLCO was present in redo-operation patients. CONCLUSIONS: Both LPS and SPECT/CT showed high predictability for actual postoperative lung function, and LPS showed good performance to estimate ppoFEV1 and ppoDLCO with reference to SPECT/CT, even in redo-operation cases. … (more)
- Is Part Of:
- European journal of cardio-thoracic surgery. Volume 58:Number 6(2020)
- Journal:
- European journal of cardio-thoracic surgery
- Issue:
- Volume 58:Number 6(2020)
- Issue Display:
- Volume 58, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 58
- Issue:
- 6
- Issue Sort Value:
- 2020-0058-0006-0000
- Page Start:
- 1228
- Page End:
- 1235
- Publication Date:
- 2020-09-03
- Subjects:
- Lung perfusion scan -- Single-photon emission computed tomography -- Predictive postoperative lung function -- Lung resection surgery
Heart -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
617.54 - Journal URLs:
- http://ejcts.oxfordjournals.org/ ↗
http://www.sciencedirect.com/science/journal/10107940 ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/ejcts/ezaa211 ↗
- Languages:
- English
- ISSNs:
- 1010-7940
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.725620
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14850.xml