Comparison of Cerebral Embolic Events Between Right and Left Upper Extremity Access During Fenestrated/Branched Endovascular Aortic Repair. (February 2021)
- Record Type:
- Journal Article
- Title:
- Comparison of Cerebral Embolic Events Between Right and Left Upper Extremity Access During Fenestrated/Branched Endovascular Aortic Repair. (February 2021)
- Main Title:
- Comparison of Cerebral Embolic Events Between Right and Left Upper Extremity Access During Fenestrated/Branched Endovascular Aortic Repair
- Authors:
- Mirza, Aleem K.
Tenorio, Emanuel R.
Marcondes, Giulianna B.
Lima, Guilherme B. B.
Macedo, Thanila A.
Mendes, Bernardo C.
Oderich, Gustavo S. - Abstract:
- Purpose: To evaluate the incidence and outcomes of cerebral embolic events when using right (RUE) vs left upper extremity (LUE) access for fenestrated/branched endovascular aneurysm repair (f/bEVAR). Materials and Methods: A retrospective review was conducted of 290 consecutive patients enrolled in a physician-sponsored Investigational Device Exemption study to evaluate f/bEVAR between 2013 and 2018. Of these, 270 patients (93%) had an upper extremity access with 12-F sheaths, including 205 patients (mean age 75±8 years; 147 men) with LUE and 65 patients (mean age 73±8 years; 42 men) with RUE access. Outcome measures were technical success, procedural metrics, major adverse events (MAEs), any stroke or transient ischemic attack (TIA), and mortality. Results: Technical success was higher (p=0.04) for LUE (99.6%) vs RUE access (98.4%). Patients treated via RUE access more often had extent I-III thoracoabdominal aortic aneurysms (57% vs 39%, p=0.03). Procedural metrics were similar for LUE vs RUE sides, including endovascular time (255±80 vs 246±83 minutes, respectively; p=0.23), fluoroscopy time (84±32 vs 90±35 minutes, respectively; p=0.80), and contrast volume (156±57 vs 153±56 mL, respectively; p=0.82). Total radiation exposure was significantly higher for LUE vs RUE access (2463±1912 vs 1757±1494 mGy, respectively; p=0.02). There were 2 deaths (1%) at 30 days or during hospital admission, both unrelated to access site complications. MAEs occurred in 32% of patients who hadPurpose: To evaluate the incidence and outcomes of cerebral embolic events when using right (RUE) vs left upper extremity (LUE) access for fenestrated/branched endovascular aneurysm repair (f/bEVAR). Materials and Methods: A retrospective review was conducted of 290 consecutive patients enrolled in a physician-sponsored Investigational Device Exemption study to evaluate f/bEVAR between 2013 and 2018. Of these, 270 patients (93%) had an upper extremity access with 12-F sheaths, including 205 patients (mean age 75±8 years; 147 men) with LUE and 65 patients (mean age 73±8 years; 42 men) with RUE access. Outcome measures were technical success, procedural metrics, major adverse events (MAEs), any stroke or transient ischemic attack (TIA), and mortality. Results: Technical success was higher (p=0.04) for LUE (99.6%) vs RUE access (98.4%). Patients treated via RUE access more often had extent I-III thoracoabdominal aortic aneurysms (57% vs 39%, p=0.03). Procedural metrics were similar for LUE vs RUE sides, including endovascular time (255±80 vs 246±83 minutes, respectively; p=0.23), fluoroscopy time (84±32 vs 90±35 minutes, respectively; p=0.80), and contrast volume (156±57 vs 153±56 mL, respectively; p=0.82). Total radiation exposure was significantly higher for LUE vs RUE access (2463±1912 vs 1757±1494 mGy, respectively; p=0.02). There were 2 deaths (1%) at 30 days or during hospital admission, both unrelated to access site complications. MAEs occurred in 32% of patients who had LUE and 26% of those who had RUE access (p=0.44). Five patients (2%) had embolic stroke and none had TIA. Embolic strokes were ipsilateral to the access side in 4 patients and affected the posterior circulation in 3. Two patients (1%) had hemorrhagic strokes. The incidence of stroke was 3% for LUE and 2% for RUE access (p>0.99). Conclusion: Fenestrated/branched stent-graft repair was associated with low rates of cerebral embolic events and no significant difference between the right vs left upper extremity approach. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 28:Number 1(2021)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 28:Number 1(2021)
- Issue Display:
- Volume 28, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 28
- Issue:
- 1
- Issue Sort Value:
- 2021-0028-0001-0000
- Page Start:
- 70
- Page End:
- 77
- Publication Date:
- 2021-02
- Subjects:
- abdominal aortic aneurysm -- brachial artery -- fenestrated/branched stent-graft -- mortality -- pararenal aneurysm -- thoracoabdominal aortic aneurysm -- stroke -- upper extremity access -- vascular access
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602820953511 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14845.xml