Area of technical uncertainty for susceptibility testing of amoxicillin/clavulanate against Escherichia coli: analysis of automated system, Etest and disk diffusion methods compared to the broth microdilution reference. (December 2020)
- Record Type:
- Journal Article
- Title:
- Area of technical uncertainty for susceptibility testing of amoxicillin/clavulanate against Escherichia coli: analysis of automated system, Etest and disk diffusion methods compared to the broth microdilution reference. (December 2020)
- Main Title:
- Area of technical uncertainty for susceptibility testing of amoxicillin/clavulanate against Escherichia coli: analysis of automated system, Etest and disk diffusion methods compared to the broth microdilution reference
- Authors:
- Soares, A.
Pestel-Caron, M.
Leysour de Rohello, F.
Bourgoin, G.
Boyer, S.
Caron, F. - Abstract:
- Abstract: Objectives: The European Committee on Antimicrobial Susceptibility Testing (EUCAST) recently warned about an area of technical uncertainty (ATU) of amoxicillin/clavulanate (AMX/C) disk susceptibility testing against members of the Enterobacterales. Thus, we aimed to compare the reliability of three routine methods and to evaluate the impact of the ATU. Methods: 286 Escherichia coli strains (including 159 AMX-resistant strains) were categorized for the two EUCAST AMX/C breakpoints by disk diffusion (Bio-Rad), the Phoenix automated system (Becton Dickinson) and the Etest (AES) compared to the broth microdilution reference method. Results: By microdilution, 84.2% of strains were AMX/C-susceptible using the urinary breakpoint (MIC ≤32 mg/L) and 62.2% using the systemic breakpoint (MIC ≤8 mg/L), with 63.6% of MICs between 4 and 16 mg/L. For the systemic breakpoint, category agreement (CA) and very major error (VME) were unacceptable for the Etest (71.7% and 27.3%), disk (73.1% and 23.4% at 19-mm cut-off) and to a lesser extent for the Phoenix system (83.6% and 10.5%). For disks, an unacceptable VME rate was observed for diameters up to 22 mm, probably due to overcharged disks. For the Etest, VMEs were high at 6 mg/L (46/63) and 8 mg/L (22/29). For the urinary breakpoint, CA was more acceptable for disk (88.9%) and Etest (84.3%) but was unevaluable for Phoenix. Conclusion: AMX/C susceptibility testing of E. coli for systemic breakpoint was unreliable with the threeAbstract: Objectives: The European Committee on Antimicrobial Susceptibility Testing (EUCAST) recently warned about an area of technical uncertainty (ATU) of amoxicillin/clavulanate (AMX/C) disk susceptibility testing against members of the Enterobacterales. Thus, we aimed to compare the reliability of three routine methods and to evaluate the impact of the ATU. Methods: 286 Escherichia coli strains (including 159 AMX-resistant strains) were categorized for the two EUCAST AMX/C breakpoints by disk diffusion (Bio-Rad), the Phoenix automated system (Becton Dickinson) and the Etest (AES) compared to the broth microdilution reference method. Results: By microdilution, 84.2% of strains were AMX/C-susceptible using the urinary breakpoint (MIC ≤32 mg/L) and 62.2% using the systemic breakpoint (MIC ≤8 mg/L), with 63.6% of MICs between 4 and 16 mg/L. For the systemic breakpoint, category agreement (CA) and very major error (VME) were unacceptable for the Etest (71.7% and 27.3%), disk (73.1% and 23.4% at 19-mm cut-off) and to a lesser extent for the Phoenix system (83.6% and 10.5%). For disks, an unacceptable VME rate was observed for diameters up to 22 mm, probably due to overcharged disks. For the Etest, VMEs were high at 6 mg/L (46/63) and 8 mg/L (22/29). For the urinary breakpoint, CA was more acceptable for disk (88.9%) and Etest (84.3%) but was unevaluable for Phoenix. Conclusion: AMX/C susceptibility testing of E. coli for systemic breakpoint was unreliable with the three routine methods, explained mainly by the high prevalence (~60%) of strains with microdilution MICs around the breakpoint (8 mg/L). Our data confirmed the EUCAST 19–20-mm ATU for disk and suggest introducing ATU for Etest MIC values of 6 and 8 mg/L. … (more)
- Is Part Of:
- Clinical microbiology and infection. Volume 26:Number 12(2020)
- Journal:
- Clinical microbiology and infection
- Issue:
- Volume 26:Number 12(2020)
- Issue Display:
- Volume 26, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 26
- Issue:
- 12
- Issue Sort Value:
- 2020-0026-0012-0000
- Page Start:
- 1685.e1
- Page End:
- 1685.e6
- Publication Date:
- 2020-12
- Subjects:
- Amoxicillin/clavulanate -- Area of technical uncertainty -- Broth microdilution -- Disk diffusion -- Escherichia coli -- EUCAST
Medical microbiology -- Periodicals
Diagnostic microbiology -- Periodicals
Communicable diseases -- Periodicals
Infection -- Periodicals
616.01 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1469-0691 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.cmi.2020.02.038 ↗
- Languages:
- English
- ISSNs:
- 1198-743X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.305520
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14869.xml