Role of a modified ultrafast MRI brain protocol in clinical paediatric neuroimaging. Issue 12 (December 2020)
- Record Type:
- Journal Article
- Title:
- Role of a modified ultrafast MRI brain protocol in clinical paediatric neuroimaging. Issue 12 (December 2020)
- Main Title:
- Role of a modified ultrafast MRI brain protocol in clinical paediatric neuroimaging
- Authors:
- Ahamed, S.H.
Lee, K.J.
Tang, P.H. - Abstract:
- Abstract : AIM: To establish a role for modified ultrafast magnetic resonance imaging (MRI) of the brain in clinical paediatric patients based on clinically acceptable image quality and diagnostic accuracy. MATERIALS AND METHODS: A prospective study was conducted with institutional review board approval on an ultrafast MRI brain protocol consisting of sagittal T1-weighted, axial T2-weighted, axial fluid-attenuated inversion recovery (FLAIR), axial diffusion-weighted imaging (DWI), and axial T2∗-weighted sequences. Preliminary investigations revealed that the default ultrafast T2-weighted sequence was prone to pulsation artefacts. A modified ultrafast T2-weighted sequence was therefore developed to replace the default ultrafast T2-weighted sequence. Thirty-five patients with clinical indication for neuroimaging underwent ultrafast MRI, modified ultrafast T2-weighted sequence and standard MRI at 3 T. Image quality of ultrafast MRI sequences were graded as clinically "diagnostic" or "non-diagnostic" and compared against the corresponding standard MRI sequences as the reference standard. The modified ultrafast T2-weighted sequence surpassed the default ultrafast T2-weighted sequence in image quality. The ultrafast MRI protocol was therefore replaced with the modified ultrafast T2-weighted sequence creating a modified ultrafast MRI protocol. The clinical reports of modified ultrafast MRI were compared against standard MRI for diagnostic concordance, categorised further asAbstract : AIM: To establish a role for modified ultrafast magnetic resonance imaging (MRI) of the brain in clinical paediatric patients based on clinically acceptable image quality and diagnostic accuracy. MATERIALS AND METHODS: A prospective study was conducted with institutional review board approval on an ultrafast MRI brain protocol consisting of sagittal T1-weighted, axial T2-weighted, axial fluid-attenuated inversion recovery (FLAIR), axial diffusion-weighted imaging (DWI), and axial T2∗-weighted sequences. Preliminary investigations revealed that the default ultrafast T2-weighted sequence was prone to pulsation artefacts. A modified ultrafast T2-weighted sequence was therefore developed to replace the default ultrafast T2-weighted sequence. Thirty-five patients with clinical indication for neuroimaging underwent ultrafast MRI, modified ultrafast T2-weighted sequence and standard MRI at 3 T. Image quality of ultrafast MRI sequences were graded as clinically "diagnostic" or "non-diagnostic" and compared against the corresponding standard MRI sequences as the reference standard. The modified ultrafast T2-weighted sequence surpassed the default ultrafast T2-weighted sequence in image quality. The ultrafast MRI protocol was therefore replaced with the modified ultrafast T2-weighted sequence creating a modified ultrafast MRI protocol. The clinical reports of modified ultrafast MRI were compared against standard MRI for diagnostic concordance, categorised further as "normal", "clinically significant", or "clinically minor" abnormalities. RESULTS: Ultrafast T1-weighted, FLAIR, and DWI sequences had comparable image quality to standard MRI sequences. The ultrafast T2∗-weighted sequence had significantly higher non-diagnostic images (42.9%) compared to the standard MRI sequence (2.9%). The default ultrafast T2-weighted sequence had significantly higher non-diagnostic images compared to the modified ultrafast T2-weighted sequence and standard T2-weighted sequence (82.9%, 5.7%, 8.6%, respectively). There was 100% concordance for normal and clinically significant abnormalities and 23% discordance for clinically minor abnormalities. Modified ultrafast MRI takes 5 minutes 41 seconds compared to standard MRI time of 14 minutes 57 seconds. CONCLUSION: The modified ultrafast MRI protocol for brain imaging demonstrates clinically acceptable image quality in four out of five sequences and has high accuracy in diagnosing normal and clinically significant abnormalities when compared against the standard MRI protocol for brain imaging. It could potentially benefit a select group of paediatric patients who require neuroimaging. Highlights: Motion prone pediatric patients could potentially benefit from ultrafast MRI brain. Ultrafast MRI brain can accurately detect clinically significant abnormalities. Ultrafast MRI brain can screen patients with low risk of having a brain abnormality. … (more)
- Is Part Of:
- Clinical radiology. Volume 75:Issue 12(2020)
- Journal:
- Clinical radiology
- Issue:
- Volume 75:Issue 12(2020)
- Issue Display:
- Volume 75, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 75
- Issue:
- 12
- Issue Sort Value:
- 2020-0075-0012-0000
- Page Start:
- 914
- Page End:
- 920
- Publication Date:
- 2020-12
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2020.07.009 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14848.xml