Induced radioactivity of a GSO scintillator by secondary fragments in carbon ion therapy and its effects on in-beam OpenPET imaging. (9th June 2016)
- Record Type:
- Journal Article
- Title:
- Induced radioactivity of a GSO scintillator by secondary fragments in carbon ion therapy and its effects on in-beam OpenPET imaging. (9th June 2016)
- Main Title:
- Induced radioactivity of a GSO scintillator by secondary fragments in carbon ion therapy and its effects on in-beam OpenPET imaging
- Authors:
- Hirano, Yoshiyuki
Nitta, Munetaka
Nishikido, Fumihiko
Yoshida, Eiji
Inadama, Naoko
Yamaya, Taiga - Abstract:
- Abstract: The accumulation of induced radioactivity within in-beam PET scanner scintillators is of concern for its long-term clinical usage in particle therapy. To estimate the effects on OpenPET which we are developing for in-beam PET based on GSOZ (Zi doped Gd2 SiO5 ), we measured the induced radioactivity of GSO activated by secondary fragments in a water phantom irradiation by a 12 C beam with an energy of 290 MeV u −1 . Radioisotopes of Na, Ce, Eu, Gd, Nd, Pm and Tb including positron emitters were observed in the gamma ray spectra of the activated GSO with a high purity Ge detector and their absolute radioactivities were calculated. We used the Monte Carlo simulation platform, Geant4 in which the observed radioactivity was assigned to the scintillators of a precisely reproduced OpenPET and the single and coincidence rates immediately after one treatment and after one-year usage were estimated for the most severe conditions. Comparing the highest coincidence rate originating from the activated scintillators (background) and the expected coincidence rate from an imaging object (signal), we determined the expected signal-to-noise ratio to be more than 7 within 3 min and more than 10 within 1 min from the scan start time. We concluded the effects of scintillator activation and their accumulation on the OpenPET imaging were small and clinical long-term usage of the OpenPET was feasible.
- Is Part Of:
- Physics in medicine & biology. Volume 61:Number 13(2016:Jul.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 61:Number 13(2016:Jul.)
- Issue Display:
- Volume 61, Issue 13 (2016)
- Year:
- 2016
- Volume:
- 61
- Issue:
- 13
- Issue Sort Value:
- 2016-0061-0013-0000
- Page Start:
- 4870
- Page End:
- 4889
- Publication Date:
- 2016-06-09
- Subjects:
- in-beam PET -- GSO scintillator -- particle therapy -- openPET -- induced radioactivity -- secondary fragments
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/0031-9155/61/13/4870 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14832.xml