A comparison of two quasi‐static computational models for assessment of intra‐myocardial injection as a therapeutic strategy for heart failure. (5th August 2019)
- Record Type:
- Journal Article
- Title:
- A comparison of two quasi‐static computational models for assessment of intra‐myocardial injection as a therapeutic strategy for heart failure. (5th August 2019)
- Main Title:
- A comparison of two quasi‐static computational models for assessment of intra‐myocardial injection as a therapeutic strategy for heart failure
- Authors:
- Fan, Yiling
Ronan, William
Teh, Irvin
Schneider, Jurgen E.
Varela, Claudia E.
Whyte, William
McHugh, Peter
Leen, Sean
Roche, Ellen - Abstract:
- Abstract: Myocardial infarction, or heart attack, is the leading cause of mortality globally. Although the treatment of myocardial infarct has improved significantly, scar tissue that persists can often lead to increased stress and adverse remodeling of surrounding tissue and ultimately to heart failure. Intra‐myocardial injection of biomaterials represents a potential treatment to attenuate remodeling, mitigate degeneration, and reverse the disease process in the tissue. In vivo experiments on animal models have shown functional benefits of this therapeutic strategy. However, a poor understanding of the optimal injection pattern, volume, and material properties has acted as a barrier to its widespread clinical adoption. In this study, we developed two quasistatic finite element simulations of the left ventricle to investigate the mechanical effect of intra‐myocardial injection. The first model employed an idealized left ventricular geometry with rule‐based cardiomyocyte orientation. The second model employed a subject‐specific left ventricular geometry with cardiomyocyte orientation from diffusion tensor magnetic resonance imaging. Both models predicted cardiac parameters including ejection fraction, systolic wall thickening, and ventricular twist that matched experimentally reported values. All injection simulations showed cardiomyocyte stress attenuation, offering an explanation for the mechanical reinforcement benefit associated with injection. The study also enabled aAbstract: Myocardial infarction, or heart attack, is the leading cause of mortality globally. Although the treatment of myocardial infarct has improved significantly, scar tissue that persists can often lead to increased stress and adverse remodeling of surrounding tissue and ultimately to heart failure. Intra‐myocardial injection of biomaterials represents a potential treatment to attenuate remodeling, mitigate degeneration, and reverse the disease process in the tissue. In vivo experiments on animal models have shown functional benefits of this therapeutic strategy. However, a poor understanding of the optimal injection pattern, volume, and material properties has acted as a barrier to its widespread clinical adoption. In this study, we developed two quasistatic finite element simulations of the left ventricle to investigate the mechanical effect of intra‐myocardial injection. The first model employed an idealized left ventricular geometry with rule‐based cardiomyocyte orientation. The second model employed a subject‐specific left ventricular geometry with cardiomyocyte orientation from diffusion tensor magnetic resonance imaging. Both models predicted cardiac parameters including ejection fraction, systolic wall thickening, and ventricular twist that matched experimentally reported values. All injection simulations showed cardiomyocyte stress attenuation, offering an explanation for the mechanical reinforcement benefit associated with injection. The study also enabled a comparison of injection location and the corresponding effect on cardiac performance at different stages of the cardiac cycle. While the idealized model has lower fidelity, it predicts cardiac function and differentiates the effects of injection location. Both models represent versatile in silico tools to guide optimal strategy in terms of injection number, volume, site, and material properties. Abstract : In preclinical models, intramyocardial injection of biomaterials has been shown to attenuate disease progression of cardiac tissue after a heart attack. Nonetheless, a poor understanding of the optimal injection pattern, volume, and material properties has posed a challenge to clinical adoption of this strategy. In this study, we developed two quasi‐static finite element simulations of the left ventricle to investigate the mechanical effect of intramyocardial injection. … (more)
- Is Part Of:
- International journal for numerical methods in biomedical engineering. Volume 35:Number 9(2019)
- Journal:
- International journal for numerical methods in biomedical engineering
- Issue:
- Volume 35:Number 9(2019)
- Issue Display:
- Volume 35, Issue 9 (2019)
- Year:
- 2019
- Volume:
- 35
- Issue:
- 9
- Issue Sort Value:
- 2019-0035-0009-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-08-05
- Subjects:
- Finite element method -- Intramyocardial injection -- Cardiac modeling -- Diffusion tensor imaging -- Diffusion tensor magnetic resonance imaging
Biomedical engineering -- Periodicals
Imaging systems in medicine -- Periodicals
Numerical analysis -- Periodicals
Engineering mathematics -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2040-7947 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cnm.3213 ↗
- Languages:
- English
- ISSNs:
- 2040-7939
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.403550
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14834.xml