Inertial Measurement Unit-Assisted Implantation of Pedicle Screws in Combination With an Intraoperative 3-Dimensional/2-Dimensional Visualization of the Spine. Issue 3 (30th May 2018)
- Record Type:
- Journal Article
- Title:
- Inertial Measurement Unit-Assisted Implantation of Pedicle Screws in Combination With an Intraoperative 3-Dimensional/2-Dimensional Visualization of the Spine. Issue 3 (30th May 2018)
- Main Title:
- Inertial Measurement Unit-Assisted Implantation of Pedicle Screws in Combination With an Intraoperative 3-Dimensional/2-Dimensional Visualization of the Spine
- Authors:
- Jost, Gregory F
Walti, Jonas
Mariani, Luigi
Schaeren, Stefan
Cattin, Philippe - Abstract:
- Abstract: BACKGROUND: Inertial measurement units (IMUs) are microelectromechanical systems used to track orientation and motion. OBJECTIVE: To use instruments mounted with IMUs in combination with a 3- and 2-dimensional (3D/2D) rendering of the computed-tomography scan (CT) to guide implantation of pedicle screws. METHODS: Pedicle screws were implanted from T1 to S1 in 2 human cadavers. A software application enabled the surgeon to select the starting points and trajectories on a 3D/2D image of the spine, then locate these starting points on the exposed spine and apply the IMU-mounted instruments to reproduce the trajectories. The position of the screws was evaluated on the postoperative CT scan. RESULTS: A total of 72 pedicle screws were implanted. Thirty-seven (77%) of the thoracic screws were within the pedicle (Heary I), 7 (15%) showed a lateral breach of the pedicle, and 4 (8%) violated the anterior or lateral vertebral body (Heary III). In the lumbar spine and S1, 21 screws (88%) were within the pedicle (Gertzbein 0), 2 (8%) screws had a pedicle wall breach < 2 mm (Gertzbein 1), and 1 > 2 to < 4 mm (Gertzbein 2). In the second cadaver, the position was compared to the intraoperatively shown virtual position. The median offset was 3°(mean 3° ± 2°, variance 5, range 0°–9°) in the sagittal plane and 3° (mean 4° ± 3°, variance 9, range 0°–12°) in the axial plane. CONCLUSION: IMU-assisted implantation of pedicle screws combined with an intraoperative 3D/2D visualization ofAbstract: BACKGROUND: Inertial measurement units (IMUs) are microelectromechanical systems used to track orientation and motion. OBJECTIVE: To use instruments mounted with IMUs in combination with a 3- and 2-dimensional (3D/2D) rendering of the computed-tomography scan (CT) to guide implantation of pedicle screws. METHODS: Pedicle screws were implanted from T1 to S1 in 2 human cadavers. A software application enabled the surgeon to select the starting points and trajectories on a 3D/2D image of the spine, then locate these starting points on the exposed spine and apply the IMU-mounted instruments to reproduce the trajectories. The position of the screws was evaluated on the postoperative CT scan. RESULTS: A total of 72 pedicle screws were implanted. Thirty-seven (77%) of the thoracic screws were within the pedicle (Heary I), 7 (15%) showed a lateral breach of the pedicle, and 4 (8%) violated the anterior or lateral vertebral body (Heary III). In the lumbar spine and S1, 21 screws (88%) were within the pedicle (Gertzbein 0), 2 (8%) screws had a pedicle wall breach < 2 mm (Gertzbein 1), and 1 > 2 to < 4 mm (Gertzbein 2). In the second cadaver, the position was compared to the intraoperatively shown virtual position. The median offset was 3°(mean 3° ± 2°, variance 5, range 0°–9°) in the sagittal plane and 3° (mean 4° ± 3°, variance 9, range 0°–12°) in the axial plane. CONCLUSION: IMU-assisted implantation of pedicle screws combined with an intraoperative 3D/2D visualization of the spine enabled the surgeon to precisely implant pedicle screws on the exposed spine. … (more)
- Is Part Of:
- Operative neurosurgery. Volume 16:Issue 3(2019)
- Journal:
- Operative neurosurgery
- Issue:
- Volume 16:Issue 3(2019)
- Issue Display:
- Volume 16, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 16
- Issue:
- 3
- Issue Sort Value:
- 2019-0016-0003-0000
- Page Start:
- 326
- Page End:
- 334
- Publication Date:
- 2018-05-30
- Subjects:
- Image-guided surgery -- Inertial measurement unit -- Navigation -- Pedicle screws -- Spine
Nervous system -- Surgery -- Periodicals
617.480590 - Journal URLs:
- https://academic.oup.com/ons/issue ↗
http://journals.lww.com/onsonline/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1093/ons/opy141 ↗
- Languages:
- English
- ISSNs:
- 2332-4252
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6269.380200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14810.xml