Spatially confined responses of mouse visual cortex to intracortical magnetic stimulation from micro-coils. (21st October 2020)
- Record Type:
- Journal Article
- Title:
- Spatially confined responses of mouse visual cortex to intracortical magnetic stimulation from micro-coils. (21st October 2020)
- Main Title:
- Spatially confined responses of mouse visual cortex to intracortical magnetic stimulation from micro-coils
- Authors:
- Ryu, Sang Baek
Paulk, Angelique C
Yang, Jimmy C
Ganji, Mehran
Dayeh, Shadi A
Cash, Sydney S
Fried, Shelley I
Lee, Seung Woo - Abstract:
- Abstract: Objective. Electrical stimulation via microelectrodes implanted in cortex has been suggested as a potential treatment for a wide range of neurological disorders. Despite some success however, the effectiveness of conventional electrodes remains limited, in part due to an inability to create specific patterns of neural activity around each electrode and in part due to challenges with maintaining a stable interface. The use of implantable micro-coils to magnetically stimulate the cortex has the potential to overcome these limitations because the asymmetric fields from coils can be harnessed to selectively activate some neurons, e.g. vertically-oriented pyramidal neurons while avoiding others, e.g. horizontally-oriented passing axons. In vitro experiments have shown that activation is indeed confined with micro-coils but their effectiveness in the intact brain of living animals has not been evaluated. Approach. To assess the efficacy of stimulation, a 128-channel custom recording microelectrode array was positioned on the surface of the visual cortex (ECoG) in anesthetized mice and responses to magnetic and electric stimulation were compared. Stimulation was delivered from electrodes or micro-coils implanted through a hole in the center of the recording array at a rate of 200 pulses per second for 100 ms. Main results. Both electric and magnetic stimulation reliably elicited cortical responses, although activation from electric stimulation was spatially expansive,Abstract: Objective. Electrical stimulation via microelectrodes implanted in cortex has been suggested as a potential treatment for a wide range of neurological disorders. Despite some success however, the effectiveness of conventional electrodes remains limited, in part due to an inability to create specific patterns of neural activity around each electrode and in part due to challenges with maintaining a stable interface. The use of implantable micro-coils to magnetically stimulate the cortex has the potential to overcome these limitations because the asymmetric fields from coils can be harnessed to selectively activate some neurons, e.g. vertically-oriented pyramidal neurons while avoiding others, e.g. horizontally-oriented passing axons. In vitro experiments have shown that activation is indeed confined with micro-coils but their effectiveness in the intact brain of living animals has not been evaluated. Approach. To assess the efficacy of stimulation, a 128-channel custom recording microelectrode array was positioned on the surface of the visual cortex (ECoG) in anesthetized mice and responses to magnetic and electric stimulation were compared. Stimulation was delivered from electrodes or micro-coils implanted through a hole in the center of the recording array at a rate of 200 pulses per second for 100 ms. Main results. Both electric and magnetic stimulation reliably elicited cortical responses, although activation from electric stimulation was spatially expansive, often extending more than 1 mm from the stimulation site, while activation from magnetic stimulation was typically confined to a ∼300 µ m diameter region around the stimulation site. Results were consistent for stimulation of both cortical layer 2/3 and layer 5 as well as across a range of stimulus strengths. Significance. The improved focality with magnetic stimulation suggests that the effectiveness of cortical stimulation can be improved. Improved focality may be particularly attractive for cortical prostheses that require high spatial resolution, e.g. devices that target sensory cortex, as it may lead to improved acuity. … (more)
- Is Part Of:
- Journal of neural engineering. Volume 17:Number 5(2020:Oct.)
- Journal:
- Journal of neural engineering
- Issue:
- Volume 17:Number 5(2020:Oct.)
- Issue Display:
- Volume 17, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 17
- Issue:
- 5
- Issue Sort Value:
- 2020-0017-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10-21
- Subjects:
- micro-magnetic stimulation -- implantable micro-coil -- primary visual cortex -- micro-electrocorticography (µ-ECoG) -- visual prosthesis
Neurosciences -- Periodicals
Biomedical engineering -- Periodicals
612.8 - Journal URLs:
- http://iopscience.iop.org/1741-2552/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1741-2552/abbd22 ↗
- Languages:
- English
- ISSNs:
- 1741-2560
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14826.xml