Comparison of 3 options for choosing control limits in biochemistry testing. (6th February 2017)
- Record Type:
- Journal Article
- Title:
- Comparison of 3 options for choosing control limits in biochemistry testing. (6th February 2017)
- Main Title:
- Comparison of 3 options for choosing control limits in biochemistry testing
- Authors:
- Manzocchi, Simone
Furman, Erika
Freeman, Kathleen - Abstract:
- Abstract : Background: The purpose of statistical quality control (QC) is to provide peace of mind with regard to the production of results that are suitable for analytically sound clinical interpretation and making reliable decisions about patient diagnosis, monitoring, and prognosis. Objectives: In this study, we compared 3 options for choosing control limits for biochemistry testing. They focus on the probability of error detection (Ped) and probability of false rejection (Pfr) achievable for a veterinary biochemical analyzer using the following 3 combinations: the quality control material (QCM) manufacturer's acceptable ranges; a standard 12s rule customized for the instrument's observed performance; and candidate rules selected for the instrument's observed performance using a computerized program (EZrules). Methods: For assessing customized QC, we used mean, SD, CV, bias, total error, and sigma metrics calculated from 3 months of control measurements on a laboratory biochemical analyzer, for 24 commonly used analytes, on 2 QCM levels. Results: Given the desirable combination of high Ped (> 90%) and low Pfr (≤ 5%), the candidate rules selected by the computerized program‐related EZrules provided the best performance combinations. Conclusions: The present work shows acceptable QC performance basing the QC on customization of the acceptable ranges of results from the achievable performance of an individual instrument. The QC performance is maximized by the application ofAbstract : Background: The purpose of statistical quality control (QC) is to provide peace of mind with regard to the production of results that are suitable for analytically sound clinical interpretation and making reliable decisions about patient diagnosis, monitoring, and prognosis. Objectives: In this study, we compared 3 options for choosing control limits for biochemistry testing. They focus on the probability of error detection (Ped) and probability of false rejection (Pfr) achievable for a veterinary biochemical analyzer using the following 3 combinations: the quality control material (QCM) manufacturer's acceptable ranges; a standard 12s rule customized for the instrument's observed performance; and candidate rules selected for the instrument's observed performance using a computerized program (EZrules). Methods: For assessing customized QC, we used mean, SD, CV, bias, total error, and sigma metrics calculated from 3 months of control measurements on a laboratory biochemical analyzer, for 24 commonly used analytes, on 2 QCM levels. Results: Given the desirable combination of high Ped (> 90%) and low Pfr (≤ 5%), the candidate rules selected by the computerized program‐related EZrules provided the best performance combinations. Conclusions: The present work shows acceptable QC performance basing the QC on customization of the acceptable ranges of results from the achievable performance of an individual instrument. The QC performance is maximized by the application of candidate rules based on customized ranges obtained from a computerized QC tool, providing the ability to achieve the highest Ped and acceptably low Pfr values. … (more)
- Is Part Of:
- Veterinary clinical pathology. Volume 46:Number 1(2017)
- Journal:
- Veterinary clinical pathology
- Issue:
- Volume 46:Number 1(2017)
- Issue Display:
- Volume 46, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 46
- Issue:
- 1
- Issue Sort Value:
- 2017-0046-0001-0000
- Page Start:
- 120
- Page End:
- 125
- Publication Date:
- 2017-02-06
- Subjects:
- Analytic performance -- probability of error detection -- probability of false rejection -- quality control -- total allowable error
Veterinary pathology -- Periodicals
636.089607 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/vcp.12453 ↗
- Languages:
- English
- ISSNs:
- 0275-6382
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9227.015500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14802.xml