Comparison of gradient echo and gradient echo sampling of spin echo sequence for the quantification of the oxygen extraction fraction from a combined quantitative susceptibility mapping and quantitative BOLD (QSM+qBOLD) approach. Issue 4 (2nd June 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of gradient echo and gradient echo sampling of spin echo sequence for the quantification of the oxygen extraction fraction from a combined quantitative susceptibility mapping and quantitative BOLD (QSM+qBOLD) approach. Issue 4 (2nd June 2019)
- Main Title:
- Comparison of gradient echo and gradient echo sampling of spin echo sequence for the quantification of the oxygen extraction fraction from a combined quantitative susceptibility mapping and quantitative BOLD (QSM+qBOLD) approach
- Authors:
- Hubertus, Simon
Thomas, Sebastian
Cho, Junghun
Zhang, Shun
Wang, Yi
Schad, Lothar Rudi - Abstract:
- Abstract : Purpose: To compare gradient echo (GRE) and gradient echo sampling of spin echo (GESSE) sequences for the quantification of the oxygen extraction fraction (OEF) from combined quantitative BOLD and quantitative susceptibility mapping (QSM) with regard to accuracy, precision and parameter initialization. Methods: GRE and GESSE data were acquired from 7 healthy volunteers. QSM was applied to the GRE data and used as a regularization for the single‐compartment quantitative BOLD fit to the GESSE and GRE data, respectively, to quantify OEF, deoxygenated blood volume (ν), R 2, and non‐blood susceptibility (χnb ). Intersubject means within gray and white matter, respectively, were compared between GESSE and GRE (Student's t) and gray–white matter contrast was determined for each sequence separately. A single‐ and multi‐compartment simulation was used to compare reconstruction accuracy. Results: Intersubject means and SDs for gray and white matter were OEF = 32.4 ± 1.6%, ν = 2.9 ± 0.1%, R 2 = 14.2 ± 0.5 Hz, χnb = −43 ± 5 ppb for GESSE and OEF = 43.0 ± 5.4%, ν = 3.5 ± 0.4%, R 2 = 14.4 ± 0.7 Hz, χnb = −43 ± 8 ppb for GRE with a significant difference ( P < 0.05) for OEF and ν. Gray–white matter contrast was significant ( P < 0.05) in all parameters for GESSE but only in ν and R 2 for GRE. All parameters reconstructed from GESSE had higher accuracy than from GRE in the single‐ but not multi‐compartment simulation. Conclusion: GESSE yields higher parameter accuracy inAbstract : Purpose: To compare gradient echo (GRE) and gradient echo sampling of spin echo (GESSE) sequences for the quantification of the oxygen extraction fraction (OEF) from combined quantitative BOLD and quantitative susceptibility mapping (QSM) with regard to accuracy, precision and parameter initialization. Methods: GRE and GESSE data were acquired from 7 healthy volunteers. QSM was applied to the GRE data and used as a regularization for the single‐compartment quantitative BOLD fit to the GESSE and GRE data, respectively, to quantify OEF, deoxygenated blood volume (ν), R 2, and non‐blood susceptibility (χnb ). Intersubject means within gray and white matter, respectively, were compared between GESSE and GRE (Student's t) and gray–white matter contrast was determined for each sequence separately. A single‐ and multi‐compartment simulation was used to compare reconstruction accuracy. Results: Intersubject means and SDs for gray and white matter were OEF = 32.4 ± 1.6%, ν = 2.9 ± 0.1%, R 2 = 14.2 ± 0.5 Hz, χnb = −43 ± 5 ppb for GESSE and OEF = 43.0 ± 5.4%, ν = 3.5 ± 0.4%, R 2 = 14.4 ± 0.7 Hz, χnb = −43 ± 8 ppb for GRE with a significant difference ( P < 0.05) for OEF and ν. Gray–white matter contrast was significant ( P < 0.05) in all parameters for GESSE but only in ν and R 2 for GRE. All parameters reconstructed from GESSE had higher accuracy than from GRE in the single‐ but not multi‐compartment simulation. Conclusion: GESSE yields higher parameter accuracy in simulated gray matter but produces unphysiological gray–white matter contrast in OEF in vivo. GRE produces uniform OEF maps in vivo and is more efficient, which could facilitate a clinical implementation, but revealed biases in simulation. The appropriate sequence should be chosen depending on application. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 82:Issue 4(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 82:Issue 4(2019)
- Issue Display:
- Volume 82, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 82
- Issue:
- 4
- Issue Sort Value:
- 2019-0082-0004-0000
- Page Start:
- 1491
- Page End:
- 1503
- Publication Date:
- 2019-06-02
- Subjects:
- GESSE -- GRE -- oxygen extraction fraction -- quantitative BOLD -- quantitative susceptibility mapping
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27804 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14789.xml