Formalin tissue fixation biases myelin‐sensitive MRI. Issue 4 (24th May 2019)
- Record Type:
- Journal Article
- Title:
- Formalin tissue fixation biases myelin‐sensitive MRI. Issue 4 (24th May 2019)
- Main Title:
- Formalin tissue fixation biases myelin‐sensitive MRI
- Authors:
- Seifert, Alan C.
Umphlett, Melissa
Hefti, Marco
Fowkes, Mary
Xu, Junqian - Abstract:
- Abstract : Purpose: Chemical fixatives such as formalin form cross‐links between proteins and affect the relaxation times and diffusion properties of tissue. These fixation‐induced changes likely also affect myelin density measurements produced by quantitative magnetization transfer and myelin water imaging. In this work, we evaluate these myelin‐sensitive MRI methods for fixation‐induced biases. Methods: We perform quantitative magnetization transfer, myelin water imaging, and deuterium oxide‐exchanged zero TE imaging on unfixed human spinal cord tissue at 9.4 Tesla and repeat these measurements after 1 day and 31 days of formalin fixation. Results: The quantitative magnetization‐transfer bound pool fraction increased by 30.7% ± 21.1% after 1 day of fixation and by 42.6% ± 33.9% after 31 days of fixation. Myelin water fraction increased by 39.7% ± 15.5% and 37.0% ± 15.9% at these same time points, and mean T2 of the myelin water pool nearly doubled. Reference‐normalized deuterium oxide‐exchanged zero TE signal intensity increased by 8.17% ± 6.03% after 31 days of fixation but did not change significantly after 1 day of fixation. After fixation, specimen cross‐sectional area decreased by approximately 5%; after correction for shrinkage, changes in deuterium oxide‐exchanged zero TE intensity were nearly eliminated. Conclusion: Bound pool fraction and myelin water fraction are significantly increased by formalin fixation, whereas deuterium oxide‐exchanged zero TE intensity isAbstract : Purpose: Chemical fixatives such as formalin form cross‐links between proteins and affect the relaxation times and diffusion properties of tissue. These fixation‐induced changes likely also affect myelin density measurements produced by quantitative magnetization transfer and myelin water imaging. In this work, we evaluate these myelin‐sensitive MRI methods for fixation‐induced biases. Methods: We perform quantitative magnetization transfer, myelin water imaging, and deuterium oxide‐exchanged zero TE imaging on unfixed human spinal cord tissue at 9.4 Tesla and repeat these measurements after 1 day and 31 days of formalin fixation. Results: The quantitative magnetization‐transfer bound pool fraction increased by 30.7% ± 21.1% after 1 day of fixation and by 42.6% ± 33.9% after 31 days of fixation. Myelin water fraction increased by 39.7% ± 15.5% and 37.0% ± 15.9% at these same time points, and mean T2 of the myelin water pool nearly doubled. Reference‐normalized deuterium oxide‐exchanged zero TE signal intensity increased by 8.17% ± 6.03% after 31 days of fixation but did not change significantly after 1 day of fixation. After fixation, specimen cross‐sectional area decreased by approximately 5%; after correction for shrinkage, changes in deuterium oxide‐exchanged zero TE intensity were nearly eliminated. Conclusion: Bound pool fraction and myelin water fraction are significantly increased by formalin fixation, whereas deuterium oxide‐exchanged zero TE intensity is minimally affected. Changes in quantitative magnetization transfer and myelin water imaging may be due in part to delamination and formation of vacuoles in the myelin sheath. Deuterium oxide‐exchanged signal intensity may be altered by fixation‐induced changes in myelin lipid solid‐state 1 H T1 . We urge caution in the comparison of these measurements across subjects or specimens in different states, especially unfixed versus fixed tissue. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 82:Issue 4(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 82:Issue 4(2019)
- Issue Display:
- Volume 82, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 82
- Issue:
- 4
- Issue Sort Value:
- 2019-0082-0004-0000
- Page Start:
- 1504
- Page End:
- 1517
- Publication Date:
- 2019-05-24
- Subjects:
- formalin fixation -- MRI -- myelin -- myelin water imaging (MWI) -- quantitative magnetization transfer (qMT) -- zero TE (ZTE) imaging
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27821 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14789.xml