A New Echocardiographic Tool for Cardiac Output Evaluation: An Experimental Study. Issue 4 (October 2019)
- Record Type:
- Journal Article
- Title:
- A New Echocardiographic Tool for Cardiac Output Evaluation: An Experimental Study. Issue 4 (October 2019)
- Main Title:
- A New Echocardiographic Tool for Cardiac Output Evaluation
- Authors:
- Bobbia, Xavier
Muller, Laurent
Claret, Pierre-Géraud
Vigouroux, Laure
Perez-Martin, Antonia
de La Coussaye, Jean Emmanuel
Lefrant, Jean Yves
Louart, Guillaume
Roger, Claire
Markarian, Thibaut - Abstract:
- ABSTRACT: Background: The correlation between cardiac output (CO) evaluated by echocardiography and CO measured by thermodilution (COth ) varies according to different studies. A new transthoracic echocardiography (TTE) tool allows automatic calculation of the subaortic velocity time index (VTIauto ) and CO (COauto ). The main objective was to evaluate the correlation between COth and COauto in an anesthetized, ventilated piglet hemorrhagic shock (HS) model. The secondary objectives were to evaluate the correlation between COth and CO evaluated by manual measurements of VTI, and the preload-dependency of VTIvaresp . Methods: Eighteen piglets were bled until mean arterial pressure reached 40 mm Hg. Controlled hemorrhage was maintained for 30 min before a resuscitation phase. CO was measured by Pulse index Contour Cardiac Output thermodilution methods. At each time of the experiment, three VTI values were measured (min, med, max) and the average value was calculated. COs were calculated by TTE (COmax, COmed, COmin, COave ). Results: For the 204 measures attempted, the success rate was 197 (97%) manually and 122 (60%) automatically ( P < 0.01). The correlation coefficients ( r ) between COth and, respectively, COauto, COave, COmax, COmed, and COmin were: 0.83 (95% CI [0.76; 0.88]; P < 0.01), 0.54 (95% CI [0.43; 0.63]; P < 0.01), 0.43 (95% CI [0.31; 0.54]; P < 0.01), 0.58 (95% CI [0.48; 0.67]; P < 0.01), and 0.52 (95% CI [0.41; 0.62]; P < 0.01). Conclusion: In anABSTRACT: Background: The correlation between cardiac output (CO) evaluated by echocardiography and CO measured by thermodilution (COth ) varies according to different studies. A new transthoracic echocardiography (TTE) tool allows automatic calculation of the subaortic velocity time index (VTIauto ) and CO (COauto ). The main objective was to evaluate the correlation between COth and COauto in an anesthetized, ventilated piglet hemorrhagic shock (HS) model. The secondary objectives were to evaluate the correlation between COth and CO evaluated by manual measurements of VTI, and the preload-dependency of VTIvaresp . Methods: Eighteen piglets were bled until mean arterial pressure reached 40 mm Hg. Controlled hemorrhage was maintained for 30 min before a resuscitation phase. CO was measured by Pulse index Contour Cardiac Output thermodilution methods. At each time of the experiment, three VTI values were measured (min, med, max) and the average value was calculated. COs were calculated by TTE (COmax, COmed, COmin, COave ). Results: For the 204 measures attempted, the success rate was 197 (97%) manually and 122 (60%) automatically ( P < 0.01). The correlation coefficients ( r ) between COth and, respectively, COauto, COave, COmax, COmed, and COmin were: 0.83 (95% CI [0.76; 0.88]; P < 0.01), 0.54 (95% CI [0.43; 0.63]; P < 0.01), 0.43 (95% CI [0.31; 0.54]; P < 0.01), 0.58 (95% CI [0.48; 0.67]; P < 0.01), and 0.52 (95% CI [0.41; 0.62]; P < 0.01). Conclusion: In an experimental model of HS, a new ultrasound tool, COauto, seems better correlated with COth than manual echocardiographic measurements. … (more)
- Is Part Of:
- Shock. Volume 52:Issue 4(2019)
- Journal:
- Shock
- Issue:
- Volume 52:Issue 4(2019)
- Issue Display:
- Volume 52, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 52
- Issue:
- 4
- Issue Sort Value:
- 2019-0052-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-10
- Subjects:
- Cardiac output -- echocardiography -- hemorrhagic -- shock -- ultrasound
Shock -- Periodicals
Shock -- Periodicals
Choc (Pathologie) -- Périodiques
Shock
Periodicals
616.0475 - Journal URLs:
- http://www.shockjournal.com ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00024382-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/SHK.0000000000001273 ↗
- Languages:
- English
- ISSNs:
- 1073-2322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8267.443000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14769.xml