Mid-term repair durability after MitraClip implantation in patients with functional mitral regurgitation. Issue 10 (October 2019)
- Record Type:
- Journal Article
- Title:
- Mid-term repair durability after MitraClip implantation in patients with functional mitral regurgitation. Issue 10 (October 2019)
- Main Title:
- Mid-term repair durability after MitraClip implantation in patients with functional mitral regurgitation
- Authors:
- Cimino, Sara
Maestrini, Viviana
Cantisani, Donatella
Petronilli, Valentina
Filomena, Domenico
Mancone, Massimo
Sardella, Gennaro
Benedetti, Giulia
Fedele, Francesco
Agati, Luciano - Abstract:
- Abstract : Background: The aim of this study was to identify variables that are associated with the durability of percutaneous repair of secondary mitral regurgitation at 6-month follow-up. Methods and results: Thirty-five consecutive patients with functional mitral regurgitation scheduled for MitraClip implant were enrolled. Left ventricular (LV) volumes and function and mitral valve characteristics were assessed before and immediately after MitraClip implantation using three-dimensional transesophageal echocardiography. Five patients with an unsuccessful procedure were excluded. The other patients were subdivided according to repair durability: group 1 with a durable repair (19 patients, 65%) and group 2 with significant mitral regurgitation recurrence (11 patients, 35%). At baseline, group 1 patients had smaller and more elliptical mitral valve annulus (1055 ± 241 vs. 1273 ± 359 mm 2, P = 0.02 and 125 ± 11 vs. 117 ± 16%, P = 0.02), a smaller left atrial volume (54.1 ± 26 vs. 71.5 ± 20 ml, P = 0.005) and lower systolic pulmonary artery pressure (38 ± 11 vs. 49 ± 12 mmHg, P = 0.03). Baseline LV end systolic volume had a linear correlation with the 3D annulus area ( P = 0.048) and an inverse correlation with annulus ellipticity ( P = 0.021). Group 1 patients showed an increase in annulus ellipticity after MitraClip (125 ± 17 vs. 141 ± 23%, P = 0.014). Conclusion: Percutaneous mitral valve repair leads to a significant and stable mitral regurgitation reduction in aAbstract : Background: The aim of this study was to identify variables that are associated with the durability of percutaneous repair of secondary mitral regurgitation at 6-month follow-up. Methods and results: Thirty-five consecutive patients with functional mitral regurgitation scheduled for MitraClip implant were enrolled. Left ventricular (LV) volumes and function and mitral valve characteristics were assessed before and immediately after MitraClip implantation using three-dimensional transesophageal echocardiography. Five patients with an unsuccessful procedure were excluded. The other patients were subdivided according to repair durability: group 1 with a durable repair (19 patients, 65%) and group 2 with significant mitral regurgitation recurrence (11 patients, 35%). At baseline, group 1 patients had smaller and more elliptical mitral valve annulus (1055 ± 241 vs. 1273 ± 359 mm 2, P = 0.02 and 125 ± 11 vs. 117 ± 16%, P = 0.02), a smaller left atrial volume (54.1 ± 26 vs. 71.5 ± 20 ml, P = 0.005) and lower systolic pulmonary artery pressure (38 ± 11 vs. 49 ± 12 mmHg, P = 0.03). Baseline LV end systolic volume had a linear correlation with the 3D annulus area ( P = 0.048) and an inverse correlation with annulus ellipticity ( P = 0.021). Group 1 patients showed an increase in annulus ellipticity after MitraClip (125 ± 17 vs. 141 ± 23%, P = 0.014). Conclusion: Percutaneous mitral valve repair leads to a significant and stable mitral regurgitation reduction in a large number of patients. Annulus dimensions and remodeling as well as left atrial area and pulmonary hypertension seem to be associated with durability of the procedure. … (more)
- Is Part Of:
- Journal of cardiovascular medicine. Volume 20:Issue 10(2019:Oct.)
- Journal:
- Journal of cardiovascular medicine
- Issue:
- Volume 20:Issue 10(2019:Oct.)
- Issue Display:
- Volume 20, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 10
- Issue Sort Value:
- 2019-0020-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-10
- Subjects:
- three-dimensional transesophageal echocardiography -- MitraClip -- mitral valve regurgitation -- percutaneous edge-to-edge valve repair
Cardiology -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cardiology -- Periodicals
Cardiovascular Diseases -- Periodicals
616.1005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=01244665-000000000-00000 ↗
http://www.jcardiovascularmedicine.com/pt/re/jcm/home.htm ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2459/JCM.0000000000000846 ↗
- Languages:
- English
- ISSNs:
- 1558-2027
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.867300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14784.xml