External Validation of Two Models to Predict Delirium in Critically Ill Adults Using Either the Confusion Assessment Method-ICU or the Intensive Care Delirium Screening Checklist for Delirium Assessment. Issue 10 (October 2019)
- Record Type:
- Journal Article
- Title:
- External Validation of Two Models to Predict Delirium in Critically Ill Adults Using Either the Confusion Assessment Method-ICU or the Intensive Care Delirium Screening Checklist for Delirium Assessment. Issue 10 (October 2019)
- Main Title:
- External Validation of Two Models to Predict Delirium in Critically Ill Adults Using Either the Confusion Assessment Method-ICU or the Intensive Care Delirium Screening Checklist for Delirium Assessment
- Authors:
- Wassenaar, Annelies
Schoonhoven, Lisette
Devlin, John W.
van Haren, Frank M. P.
Slooter, Arjen J. C.
Jorens, Philippe G.
van der Jagt, Mathieu
Simons, Koen S.
Egerod, Ingrid
Burry, Lisa D.
Beishuizen, Albertus
Matos, Joaquim
Donders, A. Rogier T.
Pickkers, Peter
van den Boogaard, Mark - Abstract:
- Abstract : Objectives: To externally validate two delirium prediction models (early prediction model for ICU delirium and recalibrated prediction model for ICU delirium) using either the Confusion Assessment Method-ICU or the Intensive Care Delirium Screening Checklist for delirium assessment. Design: Prospective, multinational cohort study. Setting: Eleven ICUs from seven countries in three continents. Patients: Consecutive, delirium-free adults admitted to the ICU for greater than or equal to 6 hours in whom delirium could be reliably assessed. Interventions: None. Measurements and Main Results: The predictors included in each model were collected at the time of ICU admission (early prediction model for ICU delirium) or within 24 hours of ICU admission (recalibrated prediction model for ICU delirium). Delirium was assessed using the Confusion Assessment Method-ICU or the Intensive Care Delirium Screening Checklist. Discrimination was determined using the area under the receiver operating characteristic curve. The predictive performance was determined for the Confusion Assessment Method-ICU and Intensive Care Delirium Screening Checklist cohort, and compared with both prediction models' original reported performance. A total of 1, 286 Confusion Assessment Method-ICU–assessed patients and 892 Intensive Care Delirium Screening Checklist–assessed patients were included. Compared with the area under the receiver operating characteristic curve of 0.75 (95% CI, 0.71–0.79) in theAbstract : Objectives: To externally validate two delirium prediction models (early prediction model for ICU delirium and recalibrated prediction model for ICU delirium) using either the Confusion Assessment Method-ICU or the Intensive Care Delirium Screening Checklist for delirium assessment. Design: Prospective, multinational cohort study. Setting: Eleven ICUs from seven countries in three continents. Patients: Consecutive, delirium-free adults admitted to the ICU for greater than or equal to 6 hours in whom delirium could be reliably assessed. Interventions: None. Measurements and Main Results: The predictors included in each model were collected at the time of ICU admission (early prediction model for ICU delirium) or within 24 hours of ICU admission (recalibrated prediction model for ICU delirium). Delirium was assessed using the Confusion Assessment Method-ICU or the Intensive Care Delirium Screening Checklist. Discrimination was determined using the area under the receiver operating characteristic curve. The predictive performance was determined for the Confusion Assessment Method-ICU and Intensive Care Delirium Screening Checklist cohort, and compared with both prediction models' original reported performance. A total of 1, 286 Confusion Assessment Method-ICU–assessed patients and 892 Intensive Care Delirium Screening Checklist–assessed patients were included. Compared with the area under the receiver operating characteristic curve of 0.75 (95% CI, 0.71–0.79) in the original study, the area under the receiver operating characteristic curve of the early prediction model for ICU delirium was 0.67 (95% CI, 0.64–0.71) for delirium as assessed using the Confusion Assessment Method-ICU and 0.70 (95% CI, 0.66–0.74) using the Intensive Care Delirium Screening Checklist. Compared with the original area under the receiver operating characteristic curve of 0.77 (95% CI, 0.74–0.79), the area under the receiver operating characteristic curve of the recalibrated prediction model for ICU delirium was 0.75 (95% CI, 0.72–0.78) for assessing delirium using the Confusion Assessment Method-ICU and 0.71 (95% CI, 0.67–0.75) using the Intensive Care Delirium Screening Checklist. Conclusions: Both the early prediction model for ICU delirium and recalibrated prediction model for ICU delirium are externally validated using either the Confusion Assessment Method-ICU or the Intensive Care Delirium Screening Checklist for delirium assessment. Per delirium prediction model, both assessment tools showed a similar moderate-to-good statistical performance. These results support the use of either the early prediction model for ICU delirium or recalibrated prediction model for ICU delirium in ICUs around the world regardless of whether delirium is evaluated with the Confusion Assessment Method-ICU or Intensive Care Delirium Screening Checklist. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Critical care medicine. Volume 47:Issue 10(2019)
- Journal:
- Critical care medicine
- Issue:
- Volume 47:Issue 10(2019)
- Issue Display:
- Volume 47, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 47
- Issue:
- 10
- Issue Sort Value:
- 2019-0047-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-10
- Subjects:
- adult -- clinical prediction -- critical illness -- delirium -- intensive care unit -- validation study
Critical care medicine -- Periodicals
Soins intensifs -- Périodiques
616.028 - Journal URLs:
- http://journals.lww.com/ccmjournal/Pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/CCM.0000000000003911 ↗
- Languages:
- English
- ISSNs:
- 0090-3493
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3487.451000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14779.xml