Effect of partial vs complete circumferential epitendinous suture placement on the biomechanical properties and gap formation of canine cadaveric tendons. Issue 8 (19th August 2020)
- Record Type:
- Journal Article
- Title:
- Effect of partial vs complete circumferential epitendinous suture placement on the biomechanical properties and gap formation of canine cadaveric tendons. Issue 8 (19th August 2020)
- Main Title:
- Effect of partial vs complete circumferential epitendinous suture placement on the biomechanical properties and gap formation of canine cadaveric tendons
- Authors:
- Duffy, Daniel J.
Chang, Yi‐Jen
Fisher, Matthew B.
Moore, George E. - Abstract:
- Abstract: Objective: To determine the effect of partial vs complete circumferential epitendinous suture (ES) placement in addition to a core suture on the biomechanical strength and gapping characteristics of repaired canine tendinous constructs. Study design: Ex vivo, biomechanical study. Sample population: Thirty‐six canine superficial digital flexor tendons. Methods: Superficial digital flexor tendons were randomly assigned to three groups (n = 12), sharply transected and repaired with a core locking‐loop suture with Group 1 a partial circumferential ES, 180° on the palmar side; Group 2 a complete circumferential ES, 360° and double knotting technique; or Group 3 a complete circumferential ES, 360° and single knotting technique. After preloading, constructs were distracted to monotonic failure. Failure mode, gap formation, yield, peak, and failure forces were analyzed. Results: Mean yield (group 1 = 68.6 N, group 2 = 106.5 N, group 3 = 114 N, P < .013), peak (group 1 = 92.8 N, group 2 = 134.6 N, group 3 = 147.3 N; P < .001), and failure (group 1 = 88.7 N, group 2 = 133.0 N, group 3 = 145.5 N, P < .001) loads differed between groups. No difference in yield ( P = .874), peak ( P = .434), or failure load ( P = .434) was detected between complete circumferential ES groups. Force to create 1‐mm ( P < .001) and 3‐mm ( P < .038) gap formation was greater in specimens with complete vs partial circumferential ES placement. Complete circumferential ES repairs failed primarilyAbstract: Objective: To determine the effect of partial vs complete circumferential epitendinous suture (ES) placement in addition to a core suture on the biomechanical strength and gapping characteristics of repaired canine tendinous constructs. Study design: Ex vivo, biomechanical study. Sample population: Thirty‐six canine superficial digital flexor tendons. Methods: Superficial digital flexor tendons were randomly assigned to three groups (n = 12), sharply transected and repaired with a core locking‐loop suture with Group 1 a partial circumferential ES, 180° on the palmar side; Group 2 a complete circumferential ES, 360° and double knotting technique; or Group 3 a complete circumferential ES, 360° and single knotting technique. After preloading, constructs were distracted to monotonic failure. Failure mode, gap formation, yield, peak, and failure forces were analyzed. Results: Mean yield (group 1 = 68.6 N, group 2 = 106.5 N, group 3 = 114 N, P < .013), peak (group 1 = 92.8 N, group 2 = 134.6 N, group 3 = 147.3 N; P < .001), and failure (group 1 = 88.7 N, group 2 = 133.0 N, group 3 = 145.5 N, P < .001) loads differed between groups. No difference in yield ( P = .874), peak ( P = .434), or failure load ( P = .434) was detected between complete circumferential ES groups. Force to create 1‐mm ( P < .001) and 3‐mm ( P < .038) gap formation was greater in specimens with complete vs partial circumferential ES placement. Complete circumferential ES repairs failed primarily by suture pull‐through compared with suture breakage in most partial circumferential ES constructs. Conclusion: Addition of a complete circumferential ES with a single or double knotting technique increased the biomechanical strength of normal tendon repairs while reducing gap formation compared with partial ES placement alone. Clinical significance: Complete circumferential ES is recommended over partial ES placement. … (more)
- Is Part Of:
- Veterinary surgery. Volume 49:Issue 8(2020)
- Journal:
- Veterinary surgery
- Issue:
- Volume 49:Issue 8(2020)
- Issue Display:
- Volume 49, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 49
- Issue:
- 8
- Issue Sort Value:
- 2020-0049-0008-0000
- Page Start:
- 1571
- Page End:
- 1579
- Publication Date:
- 2020-08-19
- Subjects:
- Veterinary surgery -- Periodicals
Veterinary Medicine -- Periodicals
Surgery -- Periodicals
Societies, Medical -- Periodicals
636.0897 - Journal URLs:
- http://www.blackwell-synergy.com/loi/vsu ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=vsu ↗
http://www.harcourthealth.com/vetsurg ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0161-3499;screen=info;ECOIP ↗ - DOI:
- 10.1111/vsu.13494 ↗
- Languages:
- English
- ISSNs:
- 0161-3499
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9231.037000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14791.xml