Robust PPG motion artifact detection using a 1-D convolution neural network. (November 2020)
- Record Type:
- Journal Article
- Title:
- Robust PPG motion artifact detection using a 1-D convolution neural network. (November 2020)
- Main Title:
- Robust PPG motion artifact detection using a 1-D convolution neural network
- Authors:
- Goh, Choon-Hian
Tan, Li Kuo
Lovell, Nigel H.
Ng, Siew-Cheok
Tan, Maw Pin
Lim, Einly - Abstract:
- Highlights: This paper have succeeded in developing a one-D convolution neural network (1-D-CNN) for the detection of artifact-free segments of PPG signals. This paper eliminated the requirement of data-dependent pulse segmentation step. This paper is robust to variations in the PPG morphological waveforms within individual subjects due to motion or environmental changes. Abstract: Background and objectives: Continuous monitoring of physiological parameters such as photoplethysmography (PPG) has attracted increased interest due to advances in wearable sensors. However, PPG recordings are susceptible to various artifacts, and thus reducing the reliability of PPG-driven parameters, such as oxygen saturation, heart rate, blood pressure and respiration. This paper proposes a one-dimensional convolution neural network (1-D-CNN) to classify five-second PPG segments into clean or artifact-affected segments, avoiding data-dependent pulse segmentation techniques and heavy manual feature engineering. Methods: Continuous raw PPG waveforms were blindly allocated into segments with an equal length (5s) without leveraging any pulse location information and were normalized with Z-score normalization methods. A 1-D-CNN was designed to automatically learn the intrinsic features of the PPG waveform, and perform the required classification. Several training hyperparameters (initial learning rate and gradient threshold) were varied to investigate the effect of these parameters on theHighlights: This paper have succeeded in developing a one-D convolution neural network (1-D-CNN) for the detection of artifact-free segments of PPG signals. This paper eliminated the requirement of data-dependent pulse segmentation step. This paper is robust to variations in the PPG morphological waveforms within individual subjects due to motion or environmental changes. Abstract: Background and objectives: Continuous monitoring of physiological parameters such as photoplethysmography (PPG) has attracted increased interest due to advances in wearable sensors. However, PPG recordings are susceptible to various artifacts, and thus reducing the reliability of PPG-driven parameters, such as oxygen saturation, heart rate, blood pressure and respiration. This paper proposes a one-dimensional convolution neural network (1-D-CNN) to classify five-second PPG segments into clean or artifact-affected segments, avoiding data-dependent pulse segmentation techniques and heavy manual feature engineering. Methods: Continuous raw PPG waveforms were blindly allocated into segments with an equal length (5s) without leveraging any pulse location information and were normalized with Z-score normalization methods. A 1-D-CNN was designed to automatically learn the intrinsic features of the PPG waveform, and perform the required classification. Several training hyperparameters (initial learning rate and gradient threshold) were varied to investigate the effect of these parameters on the performance of the network. Subsequently, this proposed network was trained and validated with 30 subjects, and then tested with eight subjects, with our local dataset. Moreover, two independent datasets downloaded from the PhysioNet MIMIC II database were used to evaluate the robustness of the proposed network. Results: A 13 layer 1-D-CNN model was designed. Within our local study dataset evaluation, the proposed network achieved a testing accuracy of 94.9%. The classification accuracy of two independent datasets also achieved satisfactory accuracy of 93.8% and 86.7% respectively. Our model achieved a comparable performance with most reported works, with the potential to show good generalization as the proposed network was evaluated with multiple cohorts (overall accuracy of 94.5%). Conclusion: This paper demonstrated the feasibility and effectiveness of applying blind signal processing and deep learning techniques to PPG motion artifact detection, whereby manual feature thresholding was avoided and yet a high generalization ability was achieved. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 196(2020)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 196(2020)
- Issue Display:
- Volume 196, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 196
- Issue:
- 2020
- Issue Sort Value:
- 2020-0196-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11
- Subjects:
- Convolution neural network -- Deep learning -- PPG signals -- Motion artifact detection
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2020.105596 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14758.xml