A modelling framework for assessment of arterial compliance by fusion of oscillometry and pulse wave velocity information. (November 2020)
- Record Type:
- Journal Article
- Title:
- A modelling framework for assessment of arterial compliance by fusion of oscillometry and pulse wave velocity information. (November 2020)
- Main Title:
- A modelling framework for assessment of arterial compliance by fusion of oscillometry and pulse wave velocity information
- Authors:
- Bogatu, Laura I.
Turco, Simona
Mischi, Massimo
Woerlee, Pierre
Bouwman, Arthur
Korsten, Erik H.H.M.
Muehlsteff, Jens - Abstract:
- Highlights: Novel approach for measuring arterial stiffness by signal fusion. Bayesian principles applied to hemodynamic parameter measurement. Easy-to-use, robust arterial stiffness measurement using standard technology. Simulation framework for arterial stiffness measurement and algorithm development. Method for data fusion of ECG, PPG and cuff-based blood pressure measurement. Abstract: Background and Objectives: Measurement of arterial compliance is recognized as important for clinical use and for enabling better understanding of circulatory system regulation mechanisms. Estimation of arterial compliance involves either a direct measure of the ratio between arterial volume and pressure changes or an inference from the pulse wave velocity (PWV). In this study we demonstrate an approach to assess arterial compliance by fusion of these two information sources. The approach is based on combining oscillometry as used for blood pressure inference and PWV measurements based on ECG/PPG. Enabling reliable arterial compliance measurements will contribute to the understanding of regulation mechanisms of the arterial tree, possibly establishing arterial compliance as a key measure relevant in hemodynamic monitoring. Methods: A measurement strategy, a physiological model, and a framework based on Bayesian principles are developed for measuring changes in arterial compliance based on combining oscillometry and PWV data. A simulation framework is used to study and validate theHighlights: Novel approach for measuring arterial stiffness by signal fusion. Bayesian principles applied to hemodynamic parameter measurement. Easy-to-use, robust arterial stiffness measurement using standard technology. Simulation framework for arterial stiffness measurement and algorithm development. Method for data fusion of ECG, PPG and cuff-based blood pressure measurement. Abstract: Background and Objectives: Measurement of arterial compliance is recognized as important for clinical use and for enabling better understanding of circulatory system regulation mechanisms. Estimation of arterial compliance involves either a direct measure of the ratio between arterial volume and pressure changes or an inference from the pulse wave velocity (PWV). In this study we demonstrate an approach to assess arterial compliance by fusion of these two information sources. The approach is based on combining oscillometry as used for blood pressure inference and PWV measurements based on ECG/PPG. Enabling reliable arterial compliance measurements will contribute to the understanding of regulation mechanisms of the arterial tree, possibly establishing arterial compliance as a key measure relevant in hemodynamic monitoring. Methods: A measurement strategy, a physiological model, and a framework based on Bayesian principles are developed for measuring changes in arterial compliance based on combining oscillometry and PWV data. A simulation framework is used to study and validate the algorithm and measurement principle in detail, motivated by previous experimental findings. Results: Simulations demonstrate the possibility of inferring arterial compliance via fusion of simultaneously acquired volume/pressure relationships and PWV data. In addition, the simulation framework demonstrates how Bayesian principles can be used to handle low signal – to – noise ratio and partial information loss. Conclusions: The developed simulation framework shows the feasibility of the proposed approach for assessment of arterial compliance by combining multiple data sources. This represents a first step towards integration of arterial compliance measurements in hemodynamic monitoring using existing clinical technology. The Bayesian approach is of particular relevance for such patient monitoring settings, where measurements are repeated frequently, context is relevant, and data is affected by artefacts. In addition, the simulation framework is necessary for future clinical-study design, in order to determine device specifications and the extent to which noise affects the inference process. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 196(2020)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 196(2020)
- Issue Display:
- Volume 196, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 196
- Issue:
- 2020
- Issue Sort Value:
- 2020-0196-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11
- Subjects:
- Pulse wave velocity -- Oscillometry -- Arterial stiffness -- Signal fusion -- Bayesian signal processing
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2020.105492 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14758.xml