Rapid test detection of anti-infliximab antibodies: performance comparison with three different immunoassays. (November 2020)
- Record Type:
- Journal Article
- Title:
- Rapid test detection of anti-infliximab antibodies: performance comparison with three different immunoassays. (November 2020)
- Main Title:
- Rapid test detection of anti-infliximab antibodies: performance comparison with three different immunoassays
- Authors:
- Rocha, Cátia
Lago, Paula
Fernandes, Samuel
Correia, Luís
Portela, Francisco
Vieira, Ana Isabel
Patita, Marta
Arroja, Bruno
Ministro, Paula
Alves, Catarina
Dias, Cláudia Camila
Magro, Fernando - Abstract:
- Background and Aims: Therapeutic drug monitoring (TDM) of infliximab (IFX) and anti-infliximab antibodies (ATIs) is essential for treatment optimisation in inflammatory bowel disease (IBD) patients. The aim of this study was to estimate and compare the agreement and accuracy between a new rapid test and three established enzyme-linked immunosorbent assays (ELISAs) to quantify ATIs levels, and to evaluate the impact of exogenous IFX on the performance of these assays. Methods: We analysed 200 serum samples from 57 IBD outpatients in IFX induction or maintenance therapy at six IBD centres in Portugal. ATI levels were quantified using the rapid test Quantum Blue® (QB) Anti-Infliximab (Bühlmann) and three established ELISAs: In-House, Theradiag (Lisa Tracker Anti-Infliximab), and Immundiagnostik (IDKmonitor Infliximab). ATIs were quantified in patients' serum samples and spiked samples with exogenous IFX, based on analytical and clinical cutoffs. Qualitative agreement and accuracy were estimated by Cohen's kappa ( k ) with 95% confidence intervals. Results: ATIs quantification with clinical cutoffs showed a slight agreement between QB rapid test and In-House [ k = 0.163 (0.051–0.276)] and Immundiagnostik [ k = 0.085 (0.000–0.177)]. Regarding IFX/ATIs status, the QB rapid test showed a substantial agreement with Theradiag [ k = 0.808 (0.729–0.888)] and a fair agreement with In-House [ k = 0.343 (0.254–0.431)] and Immundiagnostik [ k = 0.217 (0.138–0.297)]. The QB rapid testBackground and Aims: Therapeutic drug monitoring (TDM) of infliximab (IFX) and anti-infliximab antibodies (ATIs) is essential for treatment optimisation in inflammatory bowel disease (IBD) patients. The aim of this study was to estimate and compare the agreement and accuracy between a new rapid test and three established enzyme-linked immunosorbent assays (ELISAs) to quantify ATIs levels, and to evaluate the impact of exogenous IFX on the performance of these assays. Methods: We analysed 200 serum samples from 57 IBD outpatients in IFX induction or maintenance therapy at six IBD centres in Portugal. ATI levels were quantified using the rapid test Quantum Blue® (QB) Anti-Infliximab (Bühlmann) and three established ELISAs: In-House, Theradiag (Lisa Tracker Anti-Infliximab), and Immundiagnostik (IDKmonitor Infliximab). ATIs were quantified in patients' serum samples and spiked samples with exogenous IFX, based on analytical and clinical cutoffs. Qualitative agreement and accuracy were estimated by Cohen's kappa ( k ) with 95% confidence intervals. Results: ATIs quantification with clinical cutoffs showed a slight agreement between QB rapid test and In-House [ k = 0.163 (0.051–0.276)] and Immundiagnostik [ k = 0.085 (0.000–0.177)]. Regarding IFX/ATIs status, the QB rapid test showed a substantial agreement with Theradiag [ k = 0.808 (0.729–0.888)] and a fair agreement with In-House [ k = 0.343 (0.254–0.431)] and Immundiagnostik [ k = 0.217 (0.138–0.297)]. The QB rapid test could not detect ATI-positive levels in samples with exogenous IFX at 5–300 µg/ml. Interference on ATIs detection was observed at exogenous IFX ⩾30 µg/ml for In-house and Immundiagnostik assays. Conclusion: QB rapid test is only suitable to detect ATI-positive levels in the absence of IFX. … (more)
- Is Part Of:
- Therapeutic advances in gastroenterology. Volume 13(2020)
- Journal:
- Therapeutic advances in gastroenterology
- Issue:
- Volume 13(2020)
- Issue Display:
- Volume 13, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 13
- Issue:
- 2020
- Issue Sort Value:
- 2020-0013-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11
- Subjects:
- antibodies -- drug monitoring -- enzyme-linked immunosorbent assay -- immunoassay -- inflammatory bowel diseases -- infliximab -- point-of-care systems
Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Treatment -- Periodicals
Gastrointestinal system -- Diseases -- Treatment -- Periodicals
Liver -- Diseases -- Treatment -- Periodicals
Pharmacology -- Periodicals
Gastroenterology -- Periodicals
Gastrointestinal Diseases -- therapy -- Periodicals
Liver Diseases -- therapy -- Periodicals
Pharmacology -- Periodicals
Gastroentérologie -- Périodiques
Appareil digestif -- Maladies -- Traitement -- Périodiques
Tractus gastro-intestinal -- Maladies -- Traitement -- Périodiques
Hépatologie -- Périodiques
Foie -- Maladies -- Périodiques
Pharmacologie -- Périodiques
616.3005 - Journal URLs:
- http://rave.ohiolink.edu/ejournals/issn/1756283x/ ↗
http://tag.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗
http://www.tag.sagepub.com/ ↗ - DOI:
- 10.1177/1756284820965790 ↗
- Languages:
- English
- ISSNs:
- 1756-283X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14753.xml