Mechanical properties of spinal cord grey matter and white matter in confined compression. (December 2020)
- Record Type:
- Journal Article
- Title:
- Mechanical properties of spinal cord grey matter and white matter in confined compression. (December 2020)
- Main Title:
- Mechanical properties of spinal cord grey matter and white matter in confined compression
- Authors:
- Yu, Justin
Manouchehri, Neda
Yamamoto, Shun
Kwon, Brian K.
Oxland, Thomas R. - Abstract:
- Abstract: To better understand the link between spinal cord impact and the resulting tissue damage, computational models are often used. These models typically simulate the spinal cord as a homogeneous and isotropic material. Recent research suggests that grey and white matter tissue differences and directional differences, i.e. anisotropy, are important to predict spinal cord damage. The objective of this research was to characterize the mechanical properties of spinal cord grey and white matter tissue in confined compression. Spinal cords (n = 12) were harvested immediately following euthanasia from Yorkshire and Yucatan pigs. The spinal cords were flash frozen (60 s at -80 °C) and prepared into four types of test samples: grey matter axial, grey matter transverse, white matter axial, and white matter transverse. Each sample type was thawed, and subsequently tested in confined compression within 6 h of euthanasia. Samples were compressed to 10% strain at a quasi-static strain rate (0.001/sec) and allowed to relax for 120 s. A quasi-linear viscoelastic model combining a first-order exponential with a 1-term Prony series characterized the loading and relaxation responses respectively. The effect of tissue type (grey matter vs. white matter), direction (axial vs. transverse), and their interaction were evaluated with a two-way ANOVA (p < 0.05) with peak stress, aggregate modulus, and relaxation time as dependent variables. This study found grey matter to be 1.6–2 timesAbstract: To better understand the link between spinal cord impact and the resulting tissue damage, computational models are often used. These models typically simulate the spinal cord as a homogeneous and isotropic material. Recent research suggests that grey and white matter tissue differences and directional differences, i.e. anisotropy, are important to predict spinal cord damage. The objective of this research was to characterize the mechanical properties of spinal cord grey and white matter tissue in confined compression. Spinal cords (n = 12) were harvested immediately following euthanasia from Yorkshire and Yucatan pigs. The spinal cords were flash frozen (60 s at -80 °C) and prepared into four types of test samples: grey matter axial, grey matter transverse, white matter axial, and white matter transverse. Each sample type was thawed, and subsequently tested in confined compression within 6 h of euthanasia. Samples were compressed to 10% strain at a quasi-static strain rate (0.001/sec) and allowed to relax for 120 s. A quasi-linear viscoelastic model combining a first-order exponential with a 1-term Prony series characterized the loading and relaxation responses respectively. The effect of tissue type (grey matter vs. white matter), direction (axial vs. transverse), and their interaction were evaluated with a two-way ANOVA (p < 0.05) with peak stress, aggregate modulus, and relaxation time as dependent variables. This study found grey matter to be 1.6–2 times stiffer than white matter and both grey and white matter were isotropic in compression. These findings should be emphasized when studying SCI biomechanics using computational models. Graphical abstract: Image 1 Highlights: Biopsy punch design enabled sample collection and testing without sample removal. Mechanical behaviour of spinal cord tissue is strain-stiffening and viscoelastic. Grey matter tissue is stiffer than white matter tissue in compression. Grey matter tissue and white matter tissue are isotropic in compression. Modeling distinct tissue properties is more important than directional properties. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 112(2020)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 112(2020)
- Issue Display:
- Volume 112, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 112
- Issue:
- 2020
- Issue Sort Value:
- 2020-0112-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12
- Subjects:
- Spinal cord -- Confined compression -- Grey matter -- White matter -- Anisotropy -- Viscoelastic -- Biomechanics
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2020.104044 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14744.xml