Spectral-detector based x-ray absorptiometry (SDXA): in-vivo bone mineral density measurements in patients with and without osteoporotic fractures. (24th August 2020)
- Record Type:
- Journal Article
- Title:
- Spectral-detector based x-ray absorptiometry (SDXA): in-vivo bone mineral density measurements in patients with and without osteoporotic fractures. (24th August 2020)
- Main Title:
- Spectral-detector based x-ray absorptiometry (SDXA): in-vivo bone mineral density measurements in patients with and without osteoporotic fractures
- Authors:
- Laugerette, Alexis
Baum, Thomas
Gersing, Alexandra S
Schwaiger, Benedikt J
Brown, Kevin
Frerking, Lena C
Shapira, Nadav
Pfeiffer, Daniela
Rummeny, Ernst J
Proksa, Roland
Pfeiffer, Franz
Noël, Peter B - Abstract:
- Abstract: Objectives : To study whether a dual-layer spectral CT scout scan-based areal BMD estimation method, called Spectral-detector based x-ray absorptiometry (SDXA), can differentiate patients with versus without osteoporotic fractures. Methods: The ability of the method to differentiate patients with osteoporosis was evaluated by assessing the areal BMD at the spine (L1 to L4) in a group of 19 patients presenting at least one fracture and comparing these results to the areal BMD of age- and gender-matched controls (57 patients). Finally, the reproducibility of SDXA was evaluated in-vivo through the calculation of coefficients of variation (CV), using three repeated analyses performed on each patient. Results : The average areal BMD of patients presenting fractures, measured with the scout scan-based method (0.86 ± 0.17 g cm −2 ), was found to be significantly lower than the average BMD of the control group (1.00 ± 0.17 g cm −2, p = 0.043). The reproducibility of the method in-vivo was found to be reasonable, with CVs ranging between 3.1 and 6.9%. Conclusions : The results illustrate that the SDXA method for DXA-equivalent areal BMD estimation -delivers the ability to distinguish patients presenting osteoporotic fractures. Considering the total number of CT examinations worldwide, SDXA could develop to be a useful tool for truly opportunistic osteoporosis screening for a future clinical day-to-day routine.
- Is Part Of:
- Biomedical physics & engineering express. Volume 6:Number 5(2020)
- Journal:
- Biomedical physics & engineering express
- Issue:
- Volume 6:Number 5(2020)
- Issue Display:
- Volume 6, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 6
- Issue:
- 5
- Issue Sort Value:
- 2020-0006-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-08-24
- Subjects:
- dual-energy x-ray absorptiometry -- bone density -- osteoporosis -- spine -- dual-energy computed tomography (DECT) -- spectral computed tomography -- multidetector computed tomography (MDCT)
Medical physics -- Periodicals
Biophysics -- Periodicals
Biomedical engineering -- Periodicals
Medical sciences -- Periodicals
610.153 - Journal URLs:
- http://iopscience.iop.org/2057-1976/ ↗
http://www.iop.org/ ↗ - DOI:
- 10.1088/2057-1976/abab6b ↗
- Languages:
- English
- ISSNs:
- 2057-1976
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 14709.xml