Comparison of dynamic flat‐panel detector‐based chest radiography with nuclear medicine ventilation‐perfusion imaging for the evaluation of pulmonary function: A clinical validation study. Issue 10 (5th August 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of dynamic flat‐panel detector‐based chest radiography with nuclear medicine ventilation‐perfusion imaging for the evaluation of pulmonary function: A clinical validation study. Issue 10 (5th August 2020)
- Main Title:
- Comparison of dynamic flat‐panel detector‐based chest radiography with nuclear medicine ventilation‐perfusion imaging for the evaluation of pulmonary function: A clinical validation study
- Authors:
- Tanaka, Rie
Matsumoto, Isao
Tamura, Masaya
Takata, Munehisa
Kasahara, Kazuo
Ohkura, Noriyuki
Inoue, Dai
Matsuura, Yukihiro - Abstract:
- Abstract : Purpose: Dynamic chest radiography (DCR) is a flat‐panel detector (FPD)‐based functional lung imaging technique capable of measuring temporal changes in radiographic lung density due to ventilation and perfusion. The aim of this study was to determine the diagnostic performance of DCR in the evaluation of pulmonary function based on changes in radiographic lung density compared to nuclear medicine lung scans. Methods: This study included 53 patients with pulmonary disease who underwent DCR and nuclear medicine imaging at our institution. Dynamic chest radiography was conducted using a dynamic FPD system to obtain sequential chest radiographs during one breathing cycle. The maximum change in the average pixel value (Δmax ) was measured, and the percentage ofΔmax in each lung region, calculated relative to the sum of all lung regions (Δmax %), was calculated for each factor (ventilation and perfusion). The Δmax % was compared with the accumulation of radioactive agents (radioactive agents%) on ventilation and perfusion scans in each lung and lung region using correlation coefficients and scatter plots. The ratio of ventilation to perfusion Δmax % was calculated and compared with nuclear medicine ventilation‐perfusion (V/Q) findings in terms of sensitivity and specificity for V/Q mismatch in each lung region. Results: There was a high correlation between Δmax % and radioactive agents% for each lung (Ventilation: r = 0.81, perfusion: r = 0.87). However, correlationAbstract : Purpose: Dynamic chest radiography (DCR) is a flat‐panel detector (FPD)‐based functional lung imaging technique capable of measuring temporal changes in radiographic lung density due to ventilation and perfusion. The aim of this study was to determine the diagnostic performance of DCR in the evaluation of pulmonary function based on changes in radiographic lung density compared to nuclear medicine lung scans. Methods: This study included 53 patients with pulmonary disease who underwent DCR and nuclear medicine imaging at our institution. Dynamic chest radiography was conducted using a dynamic FPD system to obtain sequential chest radiographs during one breathing cycle. The maximum change in the average pixel value (Δmax ) was measured, and the percentage ofΔmax in each lung region, calculated relative to the sum of all lung regions (Δmax %), was calculated for each factor (ventilation and perfusion). The Δmax % was compared with the accumulation of radioactive agents (radioactive agents%) on ventilation and perfusion scans in each lung and lung region using correlation coefficients and scatter plots. The ratio of ventilation to perfusion Δmax % was calculated and compared with nuclear medicine ventilation‐perfusion (V/Q) findings in terms of sensitivity and specificity for V/Q mismatch in each lung region. Results: There was a high correlation between Δmax % and radioactive agents% for each lung (Ventilation: r = 0.81, perfusion: r = 0.87). However, correlation coefficients were lower (0.37 to 0.80) when comparing individual lung regions, with the upper lung regions showing the lowest correlation coefficients. The sensitivity and specificity of DCR for V/Q mismatch were 63.3% (19/30) and 60.1% (173/288), respectively. Motion artifacts occasionally increased Δmax %, resulting in false negatives. Conclusions: Ventilation and perfusion Δmax % correlated reasonably with radioactive agents% on ventilation and perfusion scans. Although the regional correlations were lower and the detection performance for V/Q mismatch was not enough for clinical use at the moment, these results suggest the potential for DCR to be used as a functional imaging modality that can be performed without the use of radioactive contrast agents. Further technical improvement is required for the implementation of DCR‐based V/Q studies. … (more)
- Is Part Of:
- Medical physics. Volume 47:Issue 10(2020)
- Journal:
- Medical physics
- Issue:
- Volume 47:Issue 10(2020)
- Issue Display:
- Volume 47, Issue 10 (2020)
- Year:
- 2020
- Volume:
- 47
- Issue:
- 10
- Issue Sort Value:
- 2020-0047-0010-0000
- Page Start:
- 4800
- Page End:
- 4809
- Publication Date:
- 2020-08-05
- Subjects:
- chest radiography -- functional imaging -- perfusion -- radiographic lung density -- ventilation
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.14407 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 14701.xml